| Parameter | Value |
|---|---|
| AWG | similar to AWG 24 |
| EAN | 4048879602303 |
| Form | 17561 |
| Coding | A-coded |
| Shield | yes |
| eClass | 27279218 |
| Material | PUR |
| Outer Ø | 7.6 mm ±5% |
| Standards | DIN EN 61076-2-101 (M12) |
| Protection | IP65, IP66K, IP67 inserted and tightened (EN 60529) |
| LED display | no |
| Jacket Color | blue |
| No. of poles | 8 |
| Configuration | fully used |
| Transfer rate | 1 Gbit/s |
| Color (jacket) | (wh-bl, bl) + (wh-or, or) + (wh-gn, gn) + (wh-br, br) |
| Material group | IEC 60664-1, category I |
| Packaging unit | 1 |
| Torsion stress | 3 Mio. |
| Wire isolation | HDPE (whbl, bl, whor, or, whgn, gn, whbr, br) |
| Diameter (core) | 4× 2× 0.25 mm² |
| Material (wire) | Cu wire, tin plated |
| Mounting method | inserted, tightened |
| Locking material | Zinc die casting, matte nickel plated |
| Locking of ports | Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing |
| Pollution Degree | 2 |
| Compression gland | M12 (SW13) |
| Material (jacket) | TPE (UL/CSA) |
| Operating voltage | max. 60 V AC/DC |
| Outer-Ø (jacket) | 7.6 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 1 Mio. |
| Cable weight [g/m] | 74,80 |
| Bend radius (fixed) | 5× outer Ø |
| Construction (core) | 7× 0.203 mm |
| Rated surge voltage | 0.8 kV |
| Transfer parameters | CAT5e (ANSI/TIA/EIA-568-B.2-2001), CAT5 Class D nach ISO/IEC 11801 |
| Bend radius (moving) | 10× outer Ø |
| Cable identification | S4W |
| optical shield cover | min. 75% |
| No./diameter of wires | 4× 2× 0.25 mm² |
| customs tariff number | 85444290 |
| Wire-Ø incl. isolation | 1.17 mm ±5% |
| Color/numbering of wires | (wh-bl, bl) + (wh-or, or) + (wh-gn, gn) + (wh-br, br) |
| Material (wire isolation) | HDPE |
| Temperature range (fixed) | -40...+80 °C |
| Temperature range (mobile) | -40...+80 °C |
| Operating current per contact | max. 2 A |
| No. of bending cycles (C-track) | max. 1 Mio. (25 °C) |
| Operating voltage (only UL listed) | max. 30 V AC/DC |
| suitable for corrugated tube (internal Ø) | without |