| Parameter | Value |
|---|---|
| AWG | similar to AWG 24 |
| EAN | 4048879105385 |
| Form | 40601 |
| Coding | M12, A-coded |
| Shield | no |
| eClass | 27279218 |
| Art.No.: | 7050-40601-6300200 |
| Material | PUR |
| Outer Ø | 4.1 mm ±5% |
| Standards | DIN EN 61076-2-104 (M8) |
| Cable Type | 3 (PUR) |
| Protection | IP65 and IP67 when plugged and screwed down (EN 60529) |
| LED display | no |
| Jacket Color | black |
| No. of poles | 3 |
| Test voltage | 2 500 V AC |
| Torsion speed | 35 cycles per min |
| Color (jacket) | black |
| Material group | IEC 60664-1, category II |
| Packaging unit | 1 |
| Torsion stress | ±180°/m |
| Wire isolation | PP (br, bl, bk) |
| Diameter (core) | 3 × 0.25 mm² |
| Material (wire) | Cu wire, bare |
| Mounting method | inserted, tightened |
| Nominal voltage | 300 V AC |
| Resistor (core) | max. 79 Ω/km (20 °C) |
| Approval (cable) | cRUus (AWM-Style 20549/10493); CE conform |
| Locking material | M8 (zinc die casting, matte nickel plated); M12 (PA) |
| Pollution Degree | 3 |
| Compression gland | M8 (SW9) |
| Material (gasket) | FKM |
| Material (jacket) | PUR (UL/CSA) |
| Operating voltage | max. 60 V AC/DC |
| Outer-Ø (jacket) | 4.1 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 10 Mio. |
| Cable weight [g/m] | 26,40 |
| Material (contact) | Copper alloy |
| thermal resistance | flame retardant UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2 |
| Bend radius (fixed) | 5 × outer Ø |
| Construction (core) | 32 × 0.1 mm (multi-strand wire class 6) |
| Rated surge voltage | 1.5 kV |
| chemical resistance | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Alternative product: | Product ComparisonMale straight – female 90°MQ12 – M83-polewith cable sleevesFurther cable lengths on request. Plastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request.FormForm40601CablesNo./diameter of wires3 × 0.25 mm²Wire isolationPP (br, bl, bk)C-track properties10 Mio.Material (jacket)PUR (UL/CSA)Outer Ø4.1 mm ±5%Bend radius (moving)10 × outer ØTemperature range (fixed)-40...+80 °CTemperature range (mobile)-25...+80 °CCable identification630Cable Type3 (PUR)Approval (cable)cRUus (AWM-Style 20549/10493); CE conformCable weight [g/m]26,40Material (wire)Cu wire, bareResistor (core)max. 79 Ω/km (20 °C)Single wire Ø (core)0.1 mmConstruction (core)32 × 0.1 mm (multi-strand wire class 6)Diameter (core)3 × 0.25 mm²AWGsimilar to AWG 24Material (wire isolation)PPMaterial property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)70 ±5 DWire-Ø incl. isolation1.25 mm ±5%Color/numbering of wiresbr, bk, blStranding combination3 wires twistedShieldnoMaterial (jacket)PURMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistantShore hardness (jacket)90 ±5 AOuter-Ø (jacket)4.1 mm ±5%Color (jacket)blackchemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)thermal resistanceflame retardant UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2Nominal voltage300 V ACTest voltage2 500 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-40...+80 °C, (+90 °C at max. 10 000 operating hours)Temperature range (mobile)-25...+80 °C, (+90 °C at max. 10 000 operating hours)Bend radius (fixed)5 × outer ØBend radius (moving)10 × outer ØNo. of bending cycles (C-track)max. 10 Mio. (25 °C)Travel speed (C-track)max. 3 m/sAcceleration (C-track)max. 10 m/s²Torsion stress±180°/mNo. of torsion cyclesmax. 2 Mio. (25 °C)Torsion speed35 cycles per minJacket ColorblackTechnical DataOperating voltagemax. 60 V AC/DCRated surge voltage1.5 kVOperating current per contactmax. 4 ANo. of poles3Material groupIEC 60664-1, category IICodingM12, A-codedLED displaynoCompression glandM8 (SW9)ProtectionIP65 and IP67 when plugged and screwed down (EN 60529)MaterialPURLocking materialM8 (zinc die casting, matte nickel plated); M12 (PA)suitable for corrugated tube (internal Ø)M12 (10 mm); M8 (6.5 mm)General dataStandardsDIN EN 61076-2-104 (M8)Mounting methodinserted, tightenedMaterial (contact)Copper alloyMaterial (contact surface)AuMaterial (gasket)FKMPollution Degree3Temperature range-25...+85 °C, depending on cable qualityCommercial datacountry of originDEcustoms tariff number85444290EAN4048879105385eClass27279218Packaging unit1 |
| Bend radius (moving) | 10 × outer Ø |
| Cable identification | 630 |
| Current load capacity | to DIN VDE 0298-4 |
| No. of torsion cycles | max. 2 Mio. (25 °C) |
| No./diameter of wires | 3 × 0.25 mm² |
| Single wire Ø (core) | 0.1 mm |
| Stranding combination | 3 wires twisted |
| customs tariff number | 85444290 |
| Acceleration (C-track) | max. 10 m/s² |
| Travel speed (C-track) | max. 3 m/s |
| Shore hardness (jacket) | 90 ±5 A |
| Wire-Ø incl. isolation | 1.25 mm ±5% |
| Color/numbering of wires | br, bk, bl |
| Material (wire isolation) | PP |
| Temperature range (fixed) | -40...+80 °C |
| Material (contact surface) | Au |
| Material property (jacket) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant |
| Temperature range (mobile) | -25...+80 °C |
| Operating current per contact | max. 4 A |
| No. of bending cycles (C-track) | max. 10 Mio. (25 °C) |
| Shore hardness (wire isolation) | 70 ±5 D |
| Material property (wire isolation) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| suitable for corrugated tube (internal Ø) | M12 (10 mm); M8 (6.5 mm) |
Technical specifications and performance data