| Parameter | Value |
|---|---|
| AWG | similar to AWG 22 |
| EAN | 4048879105651 |
| Form | 40261 |
| Coding | A-coded |
| Shield | no |
| eClass | 27279218 |
| Art.No.: | 7050-40261-2240060 |
| Outer Ø | 5.2 mm ±5% |
| Cable Type | 2 (PUR/PVC) |
| Protection | IP65/IP67 inserted and tightened (EN 60529) |
| Jacket Color | gray |
| No. of poles | 4 |
| Test voltage | 2 000 V AC |
| Color (jacket) | gray |
| Material group | IEC 60664-1, category II |
| Packaging unit | 1 |
| Wire isolation | PVC (br, wh, bl, bk) |
| Diameter (core) | 4 × 0.34 mm² |
| Material (wire) | Cu wire, bare |
| Nominal voltage | UL 300 V AC |
| Resistor (core) | max. 57 Ω/km (20 °C) |
| Approval (cable) | UL (AWM-Style 20549/1731), CSA; CE conform |
| Locking of ports | Quick connection, 1/4 turn |
| Pollution Degree | 3 |
| Compression gland | PA |
| Material (jacket) | PUR/PVC (UL/CSA) |
| Operating voltage | max. 250 V AC/DC |
| Outer-Ø (jacket) | 5.2 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 2 Mio. |
| Cable weight [g/m] | 42,68 |
| Bend radius (fixed) | 10 × outer Ø |
| Construction (core) | 42 × 0.1 mm (multi-strand wire class 6) |
| Rated surge voltage | 2.5 kV |
| chemical resistance | good resistance to oil, gasoline and chemicals |
| Alternative product: | Product ComparisonMale 90° – female 90°MQ12 – MQ12, 4-polewith cable sleevesFurther cable lengths on request. Plastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request.FormForm40261CablesNo./diameter of wires4 × 0.34 mm²Wire isolationPVC (br, wh, bl, bk)C-track properties2 Mio.Material (jacket)PUR/PVC (UL/CSA)Outer Ø5.2 mm ±5%Bend radius (moving)15 × outer ØTemperature range (fixed)-30...+80 °CTemperature range (mobile)-5...+80 °CCable identification224Cable Type2 (PUR/PVC)Approval (cable)UL (AWM-Style 20549/1731), CSA; CE conformCable weight [g/m]42,68Material (wire)Cu wire, bareResistor (core)max. 57 Ω/km (20 °C)Single wire Ø (core)0.1 mmConstruction (core)42 × 0.1 mm (multi-strand wire class 6)Diameter (core)4 × 0.34 mm²AWGsimilar to AWG 22Material (wire isolation)PVCMaterial property (wire isolation)CFC-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)43 ±5 DWire-Ø incl. isolation1.25 mm ±5%Color/numbering of wiresbr, bk, bl, whStranding combination4 wires twistedShieldnoMaterial (jacket)PUR/PVCMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistantShore hardness (jacket)80 ±5 A (PVC-under jacket); 85 ±5 A (PUR-jacket)Outer-Ø (jacket)5.2 mm ±5%Color (jacket)graychemical resistancegood resistance to oil, gasoline and chemicalsNominal voltageUL 300 V ACTest voltage2 000 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-30...+80 °CTemperature range (mobile)-5...+80 °CBend radius (fixed)10 × outer ØBend radius (moving)15 × outer ØNo. of bending cycles (C-track)max. 2 Mio. (25 °C)Traversing distance (C-track)max. 5 m (horizontal)Travel speed (C-track)max. 3.3 m/sAcceleration (C-track)max. 5 m/s²Jacket ColorgrayTechnical DataOperating voltagemax. 250 V AC/DCRated surge voltage2.5 kVOperating current per contactmax. 4 ANo. of poles4Material groupIEC 60664-1, category IICodingA-codedLocking of portsQuick connection, 1/4 turnCompression glandPAProtectionIP65/IP67 inserted and tightened (EN 60529)suitable for corrugated tube (internal Ø)10 mmGeneral dataPollution Degree3Temperature range-25...+85 °C, depending on cable qualityCommercial datacountry of originDEcustoms tariff number85444290EAN4048879105651eClass27279218Packaging unit1 |
| Bend radius (moving) | 15 × outer Ø |
| Cable identification | 224 |
| Current load capacity | to DIN VDE 0298-4 |
| No./diameter of wires | 4 × 0.34 mm² |
| Single wire Ø (core) | 0.1 mm |
| Stranding combination | 4 wires twisted |
| customs tariff number | 85444290 |
| Acceleration (C-track) | max. 5 m/s² |
| Travel speed (C-track) | max. 3.3 m/s |
| Shore hardness (jacket) | 80 ±5 A (PVC-under jacket); 85 ±5 A (PUR-jacket) |
| Wire-Ø incl. isolation | 1.25 mm ±5% |
| Color/numbering of wires | br, bk, bl, wh |
| Material (wire isolation) | PVC |
| Temperature range (fixed) | -30...+80 °C |
| Material property (jacket) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant |
| Temperature range (mobile) | -5...+80 °C |
| Operating current per contact | max. 4 A |
| Traversing distance (C-track) | max. 5 m (horizontal) |
| No. of bending cycles (C-track) | max. 2 Mio. (25 °C) |
| Shore hardness (wire isolation) | 43 ±5 D |
| Material property (wire isolation) | CFC-, cadmium-, silicone- and lead-free |
| suitable for corrugated tube (internal Ø) | 10 mm |
Technical specifications and performance data