| Parameter | Value |
|---|---|
| Form | 42201 |
| Coding | M12, A-coded |
| Material | PUR |
| Standards | DIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8) |
| Protection | IP67 inserted and tightened (EN 60529) |
| No. of poles | 3 |
| Material group | IEC 60664-1, category I |
| Locking material | PA |
| Locking of ports | Screw thread (M8/M12×1 mm) recommended torque 0.4/0.6 Nm, self-securing |
| Pollution Degree | 3 |
| Compression gland | M8 (SW9), M12 (SW13) |
| Operating voltage | max. 50 V AC/60 V DC |
| Temperature range | -25...+85 °C |
| Rated surge voltage | 1.5 kV |
| Test isolation voltage | 0.8 kV eff/rms |
| Operating current per contact | max. 4 A |
| Operating voltage (only UL listed) | max. 30 V AC/DC |
| Product article number of manufacturer | 7005-42201-0000000 |
| suitable for corrugated tube (internal Ø) | without |
Technical specifications and performance data