| Parameter | Value |
|---|---|
| EAN | 4048879710268 |
| Form | P8331 |
| Shield | yes |
| eClass | 27279221 |
| Material | Flame retardant plastic acc. to (UL 94) |
| Outer Ø | 12.8 mm ±5% |
| Protection | IP67 inserted and tightened (EN 60529) |
| LED display | no |
| Jacket Color | orange |
| No. of poles | 6 |
| Test voltage | 4000 V |
| Configuration | fully used |
| Mating cycles | ≥ 500 |
| Color (jacket) | orange |
| Material group | IEC 60664-1, category I |
| Packaging unit | 1 |
| Torsion stress | ±15°/m |
| Wire isolation | TPM (bk num, gnye) |
| Diameter (core) | 4× 2.5 + 2× 1.5 mm² |
| Material (wire) | Cu wire, bare |
| Mounting method | inserted, tightened |
| Nominal voltage | 1000 V AC |
| Resistor (core) | max. 14 Ω/km (1.5 mm²), max. 8.5 Ω/km (2.5 mm²); (20 °C) |
| Locking of ports | Quick connection, 1/4 turn |
| Pollution Degree | 3 |
| Material (jacket) | PUR (UL) |
| Operating voltage | max. 600 V AC (Power); max. 63 V AC/DC (Signal) |
| Outer-Ø (jacket) | 12.8 mm ±5% |
| Temperature range | -25...+80 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 5 Mio. |
| Material (contact) | Copper alloy |
| thermal resistance | flame retardant |
| Bend radius (fixed) | 5× outer Ø |
| Construction (core) | multi-strand wire class 5 (EN 60228) |
| Rated surge voltage | 4.0 kV |
| Bend radius (moving) | 10× outer Ø |
| Cable identification | P11 |
| No./diameter of wires | 4× 2.5 + 2× 1.5 mm² |
| customs tariff number | 85444290 |
| Acceleration (C-track) | max. 5 m/s² |
| Travel speed (C-track) | max. 3 m/s |
| Color/numbering of wires | bk numbered, gnye longitudinally striped |
| Material (wire isolation) | TPM |
| Stripping length (jacket) | 30 mm |
| Temperature range (fixed) | -25...+80 °C |
| Material (contact carrier) | PA |
| Material (contact surface) | Ag |
| Temperature range (mobile) | -20...+80 °C |
| Operating current per contact | max. 16 A (Power); max. 10 A (Signal) |
| Traversing distance (C-track) | max. 5 m (horizontal) |
Technical specifications and performance data