| Parameter | Value |
|---|---|
| AWG | similar to AWG 24 |
| EAN | 4048879121231 |
| Form | 88311 |
| Coding | M12, A-coded |
| Shield | no |
| eClass | 27279218 |
| Art.No.: | 7000-88311-0510200 |
| Material | PUR |
| Outer Ø | 4.7 mm ±5% |
| Cable Type | 5 (PUR schweißfunkenbeständig) |
| Protection | IP65, IP66K, IP67 inserted and tightened (EN 60529) |
| LED display | no |
| Jacket Color | yellow |
| No. of poles | 4 |
| Test voltage | 2 500 V AC |
| Torsion speed | 35 cycles per min |
| Color (jacket) | yellow |
| Material group | IEC 60664-1, category I |
| Packaging unit | 1 |
| Torsion stress | ±360°/m |
| Wire isolation | PP (br, wh, bl, bk) |
| Diameter (core) | 4 × 0.25 mm² |
| Material (wire) | Cu wire, bare |
| Mounting method | inserted, tightened |
| Nominal voltage | 300 V AC |
| Resistor (core) | max. 79 Ω/km (20 °C) |
| Approval (cable) | cRUus (AWM-Style 20549/10493); CE conform |
| Locking material | Zinc die casting, save-cover coated |
| Locking of ports | Screw thread M8/M12 × 1 mm (recommended torque 0.4/0.6 Nm) self-securing |
| Pollution Degree | 3 |
| Compression gland | M8 (SW9), M12 (SW13) |
| Material (gasket) | FKM |
| Material (jacket) | PUR (UL/CSA), welding spark |
| Operating voltage | 50 V AC/60 V DC |
| Outer-Ø (jacket) | 4.7 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 10 Mio. |
| Cable weight [g/m] | 31,90 |
| Material (contact) | Copper alloy |
| thermal resistance | flame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistant |
| Bend radius (fixed) | 5 × outer Ø |
| Construction (core) | 32 × 0.1 mm (multi-strand wire class 6) |
| Rated surge voltage | 1.5 kV |
| chemical resistance | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Alternative product: | Product ComparisonMale 90° – female straightM8 – M12, 4-poleA-codedArt-No. 7005 - M12/M8 Lite - (plastic hexagonal screw) on requestZinc die casting, save-cover coatedFurther cable lengths on request. Plastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request.FormForm88311CablesNo./diameter of wires4 × 0.25 mm²Wire isolationPP (br, wh, bl, bk)C-track properties10 Mio.Material (jacket)PUR (UL/CSA), welding sparkOuter Ø4.7 mm ±5%Bend radius (moving)10 × outer ØTemperature range (fixed)-40...+80 °CTemperature range (mobile)-25...+80 °CCable identification051Cable Type5 (PUR schweißfunkenbeständig)Approval (cable)cRUus (AWM-Style 20549/10493); CE conformCable weight [g/m]31,90Material (wire)Cu wire, bareResistor (core)max. 79 Ω/km (20 °C)Single wire Ø (core)0.1 mmConstruction (core)32 × 0.1 mm (multi-strand wire class 6)Diameter (core)4 × 0.25 mm²AWGsimilar to AWG 24Material (wire isolation)PPMaterial property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)74 ±3 DWire-Ø incl. isolation1.25 mm ±5%Color/numbering of wiresbr, bk, bl, whStranding combination4 wires twistedShieldnoMaterial (jacket)PURMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistantShore hardness (jacket)58 ±3 DOuter-Ø (jacket)4.7 mm ±5%Color (jacket)yellowchemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)thermal resistanceflame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistantNominal voltage300 V ACTest voltage2 500 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-40...+80 °C, (+90 °C at max. 10 000 operating hours)Temperature range (mobile)-25...+80 °C, (+90 °C at max. 10 000 operating hours)Bend radius (fixed)5 × outer ØBend radius (moving)10 × outer ØNo. of bending cycles (C-track)max. 10 Mio. (25 °C)Traversing distance (C-track)max. 5 m (horizontal)Travel speed (C-track)max. 3.3 m/sAcceleration (C-track)max. 5 m/s²Torsion stress±360°/mNo. of torsion cyclesmax. 1 Mio. (25 °C)Torsion speed35 cycles per minJacket ColoryellowTechnical DataOperating voltage50 V AC/60 V DCOperating voltage (only UL listed)30 V AC/DCRated surge voltage1.5 kVOperating current per contactmax. 4 ANo. of poles4Material groupIEC 60664-1, category ICodingM12, A-codedLED displaynoLocking of portsScrew thread M8/M12 × 1 mm (recommended torque 0.4/0.6 Nm) self-securingCompression glandM8 (SW9), M12 (SW13)ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)MaterialPURsuitable for corrugated tube (internal Ø)M12 (10 mm); M8 (6.5 mm)Locking materialZinc die casting, save-cover coatedGeneral dataMounting methodinserted, tightenedMaterial (contact)Copper alloyMaterial (contact surface)AuMaterial (gasket)FKMPollution Degree3Temperature range-25...+85 °C, depending on cable qualityCommercial datacountry of originDEcustoms tariff number85444290EAN4048879121231eClass27279218Packaging unit1 |
| Bend radius (moving) | 10 × outer Ø |
| Cable identification | 051 |
| Current load capacity | to DIN VDE 0298-4 |
| No. of torsion cycles | max. 1 Mio. (25 °C) |
| No./diameter of wires | 4 × 0.25 mm² |
| Single wire Ø (core) | 0.1 mm |
| Stranding combination | 4 wires twisted |
| customs tariff number | 85444290 |
| Acceleration (C-track) | max. 5 m/s² |
| Travel speed (C-track) | max. 3.3 m/s |
| Shore hardness (jacket) | 58 ±3 D |
| Wire-Ø incl. isolation | 1.25 mm ±5% |
| Color/numbering of wires | br, bk, bl, wh |
| Material (wire isolation) | PP |
| Temperature range (fixed) | -40...+80 °C |
| Material (contact surface) | Au |
| Material property (jacket) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistant |
| Temperature range (mobile) | -25...+80 °C |
| Operating current per contact | max. 4 A |
| Traversing distance (C-track) | max. 5 m (horizontal) |
| No. of bending cycles (C-track) | max. 10 Mio. (25 °C) |
| Shore hardness (wire isolation) | 74 ±3 D |
| Material property (wire isolation) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| Operating voltage (only UL listed) | 30 V AC/DC |
| suitable for corrugated tube (internal Ø) | M12 (10 mm); M8 (6.5 mm) |
Technical specifications and performance data