| Parameter | Value |
|---|---|
| min. 85% | |
| EAN | 4048879698894 |
| Form | 44811 |
| Coding | D-coded |
| Shield | yes |
| eClass | 27061801 |
| Weight: | 0.457 kg |
| Art.No.: | 7000-44811-7920600 |
| Material | PUR |
| Outer Ø | 6.7 mm ±5% |
| Standards | DIN EN 61076-2-101 (M12) |
| Protection | IP67 inserted and tightened (EN 60529) |
| LED display | no |
| Cable number | 792 |
| Jacket Color | red |
| No. of poles | 4 |
| Transfer rate | up to 100 Mbit/s full duplex |
| Color (jacket) | red |
| Material group | IEC 60664-1, category I |
| Packaging unit | 1 |
| Wire isolation | PO (wh, ye, bl, or) |
| Diameter (core) | 2×2×AWG22 |
| Material (wire) | Cu wire, bare |
| Mounting method | inserted, tightened |
| Nominal voltage | 300 V |
| Resistor (core) | max. 55 Ω/km (20 °C) |
| Approval (cable) | UL (AWM-Style 20233/11602), CSA; CE |
| Locking material | Zinc die casting, matte nickel plated |
| Locking of ports | Screw thread M12 × 1 mm (recommended torque 0.6 Nm) self-securing |
| Pollution Degree | 3 |
| Compression gland | M12 (SW13) |
| Material (gasket) | FKM |
| Material (jacket) | PUR (UL/CSA) |
| Operating voltage | max. 60 V DC |
| Outer-Ø (jacket) | 6.7 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 3 Mio. |
| Cable weight [g/m] | 69,30 |
| Material (contact) | Copper alloy |
| thermal resistance | flame retardant |
| Bend radius (fixed) | 5 × outer Ø |
| Rated surge voltage | 1.5 kV |
| Transfer parameters | CAT5, Class D (ISO/IEC 11801:2002), (EN 50173-1) |
| Bend radius (moving) | 12 × outer Ø |
| Cable identification | 792 |
| No./diameter of wires | 2×2×0.34 mm² |
| customs tariff number | 85444290 |
| Acceleration (C-track) | max. 2 m/s² |
| Travel speed (C-track) | max. 3.3 m/s |
| Wire-Ø incl. isolation | 1.4 mm ±5% |
| Color/numbering of wires | wh, ye, bl, or |
| Material (wire isolation) | PO |
| Temperature range (fixed) | -40...+80 °C |
| Material (contact surface) | Au |
| Temperature range (mobile) | -30...+70 °C |
| Operating current per contact | max. 4 A |
| Traversing distance (C-track) | max. 5 m (horizontal) |
| No. of bending cycles (C-track) | max. 3 Mio. (25 °C) |
| Operating voltage (only UL listed) | 30 V DC |
| suitable for corrugated tube (internal Ø) | without |
Technical specifications and performance data
Installation and operation guide