| Parameter | Value |
|---|---|
| Form | 44717 |
| Coding | M12, D-coded |
| Shield | yes |
| Standards | DIN EN 61076-2-101 (M12), IEC 60603-7 (RJ45) |
| Protection | IP65, IP67 (RJ45) - IP65, IP66K, IP67 (M12) |
| Cable length | 0,3 m |
| Test voltage | 2000 V AC (test duration 1 min) |
| Shield (Type) | Copper braid |
| Transfer rate | 100 Mbit/s |
| Color (jacket) | green |
| Material group | IEC 60664-1, category I |
| Torsion stress | ±180°/m |
| Diameter (core) | 1× 4× AWG22/7 |
| Material (wire) | Cu wire, bare |
| Nominal voltage | 300 V |
| Resistor (core) | max. 55 Ω/km (20 °C) |
| Approval (cable) | cURus (AWM-Style 20549/11602), CE-conform |
| Locking material | Zinc die casting, matte nickel plated |
| Locking of ports | Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing |
| Pollution Degree | 3 |
| Compression gland | M12 (SW13) |
| Material (jacket) | PUR |
| Operating voltage | max. 60 V DC |
| Outer-Ø (jacket) | 6.7 mm ±5% |
| Temperature range | -40...+70 °C (RJ45), -25...+85 °C (M12) |
| Cable weight [g/m] | 69,3 g |
| thermal resistance | flame-retardant according to UL 1581 section 1090, section 1100 (FT2), IEC 60332-1-2 Std. |
| Bend radius (fixed) | 5× outer Ø |
| Construction (core) | 7× 0.254 mm |
| Rated surge voltage | 1.0 kV |
| Transfer parameters | CAT5e, Class D (ISO/IEC 11801) |
| chemical resistance | Oil resistance according to IEC 60811-2-1, ASTM IRM 901, ICEA S-82-552 Std. |
| Bend radius (moving) | 12× outer Ø |
| Cable identification | 796 |
| optical shield cover | min. 85% |
| No. of torsion cycles | max. 1 Mio. (25 °C) |
| Acceleration (C-track) | max. 2 m/s² |
| Travel speed (C-track) | max. 3.3 m/s |
| Wire-Ø incl. isolation | 1.4 mm ±5% |
| Color/numbering of wires | wh, ye, bl, or |
| Material (wire isolation) | PE |
| Temperature range (fixed) | -40...+80 °C |
| Material property (jacket) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant |
| Temperature range (mobile) | -30...+70 °C |
| Operating current per contact | max. 1.5 A |
| Traversing distance (C-track) | max. 5 m (horizontal) |
| No. of bending cycles (C-track) | max. 3 Mio. (25 °C) |
| Product article number of manufacturer | 7000-44717-7960030 |
| suitable for corrugated tube (internal Ø) | without |