| Parameter | Value |
|---|---|
| AWG | similar to AWG 22 |
| EAN | 4048879447744 |
| Form | 40761 |
| Coding | A-coded |
| Shield | no |
| eClass | 27279218 |
| Art.No.: | 7000-40761-2330250 |
| Material | PUR |
| Outer Ø | 4.1 mm ±5% |
| Standards | DIN EN 61076-2-101 (M12) |
| Cable Type | 3 (PUR) |
| Protection | IP65, IP66K, IP67 inserted and tightened (EN 60529) |
| Jacket Color | gray |
| Test voltage | 2 500 V AC |
| Torsion speed | 35 cycles/min |
| Color (jacket) | gray |
| Material group | IEC 60664-1, category I |
| Packaging unit | 1 |
| Torsion stress | ±180°/m |
| Wire isolation | PP (br, bl, bk) |
| Diameter (core) | 3 × 0.34 mm² |
| Material (wire) | Cu wire, bare |
| Nominal voltage | 300 V AC |
| Resistor (core) | max. 57 Ω/km (20 °C) |
| Approval (cable) | cRUus (AWM-Style 20549/10493); CE conform |
| Locking material | Zinc die casting, matte nickel plated |
| Locking of ports | Screw thread M12 × 1 mm (recommended torque 0.6 Nm) self-securing |
| Pollution Degree | 3 |
| Compression gland | M12 (SW13) |
| Material (gasket) | FKM |
| Material (jacket) | PUR (UL/CSA) |
| Operating voltage | max. 250 V AC/DC |
| Outer-Ø (jacket) | 4.1 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 10 Mio. |
| Cable weight [g/m] | 29,70 |
| thermal resistance | flame retardant UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2 |
| Bend radius (fixed) | 5 × outer Ø |
| Construction (core) | 42 × 0.1 mm (multi-strand wire class 6) |
| Rated surge voltage | 2.5 kV |
| chemical resistance | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Alternative product: | Product ComparisonMale straight – females 90°Y-connector M12 – M12, 4-polebridgedArt-No. 7005 - M12 Lite - (plastic hexagonal screw) on requestPlastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request. Further cable lengths on request.FormForm40761CablesNo./diameter of wires3 × 0.34 mm²C-track properties10 Mio.Wire isolationPP (br, bl, bk)Material (jacket)PUR (UL/CSA)Outer Ø4.1 mm ±5%Bend radius (moving)10 × outer ØTemperature range (fixed)-40...+80 °CTemperature range (mobile)-25...+80 °CCable identification233Cable Type3 (PUR)Approval (cable)cRUus (AWM-Style 20549/10493); CE conformCable weight [g/m]29,70Material (wire)Cu wire, bareResistor (core)max. 57 Ω/km (20 °C)Single wire Ø (core)0.1 mmConstruction (core)42 × 0.1 mm (multi-strand wire class 6)Diameter (core)3 × 0.34 mm²AWGsimilar to AWG 22Material (wire isolation)PPMaterial property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)70 ±5 DWire-Ø incl. isolation1.25 mm ±5%Color/numbering of wiresbr, bk, blStranding combination3 wires twistedShieldnoMaterial (jacket)PURMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistantShore hardness (jacket)90 ±5 AOuter-Ø (jacket)4.1 mm ±5%Color (jacket)graychemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)thermal resistanceflame retardant UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2Nominal voltage300 V ACTest voltage2 500 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-40...+80 °C, (+90 °C at max. 10 000 operating hours)Temperature range (mobile)-25...+80 °C, (+90 °C at max. 10 000 operating hours)Bend radius (fixed)5 × outer ØBend radius (moving)10 × outer ØNo. of bending cycles (C-track)max. 10 Mio. (25 °C)Travel speed (C-track)max. 3 m/sAcceleration (C-track)max. 10 m/s²Torsion stress±180°/mNo. of torsion cyclesmax. 2 Mio. (25 °C)Torsion speed35 cycles/minJacket ColorgrayTechnical DataOperating voltagemax. 250 V AC/DCOperating voltage (only UL listed)max. 30 V AC/DCRated surge voltage2.5 kVOperating current per contactmax. 4 AMaterial groupIEC 60664-1, category ICodingA-codedLocking of portsScrew thread M12 × 1 mm (recommended torque 0.6 Nm) self-securingCompression glandM12 (SW13)ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)Locking materialZinc die casting, matte nickel platedMaterialPURsuitable for corrugated tube (internal Ø)10 mmGeneral dataStandardsDIN EN 61076-2-101 (M12)Pollution Degree3Temperature range-25...+85 °C, depending on cable qualityMaterial (gasket)FKMCommercial datacountry of originDEcustoms tariff number85444290EAN4048879447744eClass27279218Packaging unit1 |
| Bend radius (moving) | 10 × outer Ø |
| Cable identification | 233 |
| Current load capacity | to DIN VDE 0298-4 |
| No. of torsion cycles | max. 2 Mio. (25 °C) |
| No./diameter of wires | 3 × 0.34 mm² |
| Single wire Ø (core) | 0.1 mm |
| Stranding combination | 3 wires twisted |
| customs tariff number | 85444290 |
| Acceleration (C-track) | max. 10 m/s² |
| Travel speed (C-track) | max. 3 m/s |
| Shore hardness (jacket) | 90 ±5 A |
| Wire-Ø incl. isolation | 1.25 mm ±5% |
| Color/numbering of wires | br, bk, bl |
| Material (wire isolation) | PP |
| Temperature range (fixed) | -40...+80 °C |
| Material property (jacket) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant |
| Temperature range (mobile) | -25...+80 °C |
| Operating current per contact | max. 4 A |
| No. of bending cycles (C-track) | max. 10 Mio. (25 °C) |
| Shore hardness (wire isolation) | 70 ±5 D |
| Material property (wire isolation) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| Operating voltage (only UL listed) | max. 30 V AC/DC |
| suitable for corrugated tube (internal Ø) | 10 mm |
Technical specifications and performance data
Installation and operation guide