| Parameter | Value |
|---|---|
| AWG | similar to AWG 24 |
| Form | 40601 |
| Coding | A-coded |
| Shield | no |
| Material | PUR |
| Standards | DIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8) |
| Cable Type | 3 (PUR) |
| Protection | IP67 inserted and tightened (EN 60529) |
| Cable length | 0,4 m |
| No. of poles | 3 |
| Test voltage | 2500 V AC |
| Torsion speed | 35 cycles/min |
| Color (jacket) | yellow |
| Material group | IEC 60664-1, category I |
| Torsion stress | ±180°/m |
| Diameter (core) | 3× 0.25 mm² |
| Material (wire) | Cu wire, bare |
| Mounting method | inserted, tightened |
| Nominal voltage | 300 V AC |
| Resistor (core) | max. 79 Ω/km (20 °C) |
| Approval (cable) | cURus (AWM-Style 20549/10493); CE conform |
| Locking material | Zinc die casting, matte nickel plated |
| Locking of ports | Screw thread (M8/M12×1 mm) recommended torque 0.4/0.6 Nm, self-securing |
| Pollution Degree | 3 |
| Compression gland | M8 (SW9), M12 (SW13) |
| Material (gasket) | FKM |
| Material (jacket) | PUR |
| Operating voltage | max. 50 V AC/60 V DC |
| Outer-Ø (jacket) | 4.1 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| Cable weight [g/m] | 26,4 g |
| thermal resistance | flame retardand UL 1581 Section 1090 (H), CSA FT2 / IEC 60332-2-2 |
| Bend radius (fixed) | 5× outer Ø |
| Construction (core) | 32× 0.1 mm (multi-strand wire class 6) |
| Rated surge voltage | 1.5 kV |
| chemical resistance | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Bend radius (moving) | 10× outer Ø |
| Cable identification | 030 |
| Current load capacity | to DIN VDE 0298-4 |
| No. of torsion cycles | max. 2 Mio. (25 °C) |
| Single wire Ø (core) | 0.1 mm |
| Stranding combination | 3 wires twisted |
| Acceleration (C-track) | max. 10 m/s² |
| Travel speed (C-track) | max. 3 m/s |
| Shore hardness (jacket) | 90 ±5 A |
| Wire-Ø incl. isolation | 1.25 mm ±5% |
| Color/numbering of wires | br, bk, bl |
| Material (wire isolation) | PP |
| Temperature range (fixed) | -40...+80 °C, (+90 °C at max. 10 000 operating hours) |
| Material (contact surface) | Au |
| Material (housing surface) | Copper alloy |
| Material property (jacket) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant |
| Temperature range (mobile) | -25...+80 °C, (+90 °C at max. 10 000 operating hours) |
| Operating current per contact | max. 4 A |
| No. of bending cycles (C-track) | max. 10 Mio. (25 °C) |
| Shore hardness (wire isolation) | 70 ±5 D |
| Material property (wire isolation) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| Operating voltage (only UL listed) | max. 30 V AC/DC |
| Product article number of manufacturer | 7000-40601-0300040 |
| suitable for corrugated tube (internal Ø) | M12 (10 mm); M8 (6.5 mm) |
Technical specifications and performance data