| Parameter | Value |
|---|---|
| AWG | similar to AWG 22 |
| Form | 40041 |
| Material | PUR |
| Shielded | No |
| Standards | DIN EN 61076-2-101 (M12) |
| Cable type | 3 (PUR) |
| Protection | IP65, IP66K, IP67 in plugged in and screwed state (EN 60529) |
| Cover color | grey |
| Cable glands | M12 (SW13) |
| Cable length | 0.15 m |
| Codification | Encoded A |
| Test voltage | 2500 V AC |
| Torque speed | 35 cycles/minute |
| Travel speed | Max. 3 m/s |
| Color (cover) | grey |
| Energy chains | 10 Mio. |
| Material group | IEC 60664-1, category I |
| Torsion stress | ±180/m |
| Nominal voltage | 300 V AC |
| Approval (cable) | cURus (AWM-Style 20549/10493); CE conforms |
| Cable insulation | PP (ma, bl, az, ne, ve-am) |
| Diameter (cable) | 5× 0.34 mm² |
| Locking material | Zinc alloy, matt nickel plating |
| Material (cable) | Cable Cu, peeled |
| Material (cover) | PUR |
| Operating voltage | Max. 125 V AC/DC |
| Temperature range | -25...+85 °C, depending on cable type |
| resistance (main) | Max. 57 Ω/km (20 °C) |
| Cable Weight [G/m] | 41.8 g |
| Thermal resistance | flame retardand UL 1581 Section 1090 (H), CSA FT2 / IEC 60332-2-2 |
| Unifilar Ø (main) | 0.1 mm |
| Torsion combination | 5 threads braided around a central filling |
| chemical resistance | good resistance to oils, gasoline and chemicals (EN 60811-404) |
| Ø exterior (cover) | 4.8 mm ±5% |
| Cable identification | 235 |
| Cable color/numbering | ma, ne, az, bl, ve-am longitudinal stripes |
| Closure of the tracks | Screw (M12×1 mm) torque recommended 0.6 Nm, self-safe |
| Current load capacity | to DIN VDE 0298-4 |
| Manufacturing (cable) | 42× 0.1 mm (class 6 multi-row cable) |
| Shore hardness (cover) | 90 ±5 A |
| Degree of contamination | 3 |
| Number of torque cycles | Max. 2 Mio. (25 °C) |
| N°/diameter of threads | 5× 0.34 mm² |
| Ø outside of the cable | 4.8 mm ±5% |
| Cable-Ø incl. Isolation | 1.25 mm ±5% |
| Temperature range (fixed) | -40...+80 °C |
| Temperature range (mobile) | -25...+80 °C |
| Working current by contact | Max. 4 A |
| Material (cable insulation) | PP |
| radius of curvature (fixed) | 5× Ø exterior |
| Acceleration (energy chains) | Max. 10 m/s² |
| Radius of curvature (mobile) | 10× Ø exterior |
| operating voltage (UL listed only) | Max. 30 V AC/DC |
| Shore resistance (cable insulation) | 70 ±5 D |
| Material properties (cable insulation) | Free of CFCs, halogens, cadmium, silicone and lead |
| Product article number of manufacturer | 7000-40041-2350015 |
| suitable for corrugated tube (Ø int.) | 10 mm |
| Characteristics of the material (cover) | Free of CFCs, halogens, cadmium, silicone and lead, matte, low adhesion, easy to process in the machine, resistant to abrasion, hydrolysis and microbes |
| Number of bending cycles (energy chains) | Max. 10 Mio. (25 °C) |