| Parameter | Value |
|---|---|
| Form | 15625 |
| Coding | Y-coded |
| Material | PUR |
| Standards | DIN EN 61076-2-101 (M12) |
| Protection | IP67 inserted and tightened (EN 60529) |
| LED display | no |
| Cable length | 1 m |
| Cable number | 942 |
| No. of poles | 8 |
| Material group | IEC 60664-1, category I |
| Torsion stress | 2 Mio. ±30°/m |
| Wire isolation | PP (bk, br, wh, bl), (whor, or, whgn, gn) |
| Protection NEMA | 3, 4, 6P (UL 50E) |
| Locking material | Brass, nickel plated |
| Locking of ports | Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing |
| Pollution Degree | 3 |
| Compression gland | M12 (SW14) |
| Material (gasket) | FKM |
| Operating voltage | max. 30 V AC/DC |
| Temperature range | -25...+85 °C |
| C-track properties | 5 Mio. |
| Material (contact) | Copper alloy |
| Bend radius (fixed) | 5× outer Ø |
| Rated surge voltage | 0.8 kV |
| Bend radius (moving) | 10× outer Ø |
| No./diameter of wires | 4× AWG20/19 (0.615) + 1× 4× AWG26/19 (0.155) |
| Temperature range (fixed) | -50...+80 °C |
| Material (contact surface) | Au |
| Temperature range (mobile) | -40...+80 °C |
| Operating current per contact | max. 6 A (contact 5...8); max. 0.5 A (contact 1...4) |
| Product article number of manufacturer | 7000-15625-9420100 |
| suitable for corrugated tube (internal Ø) | without |
Technical specifications and performance data
Installation and operation guide