Service time: Monday to Friday 9:00-18:00
6SL3210-1PE32-5AL0 - 6SL3210-1PE32-5AL0 SIEMENS SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKI..
In Stock Hot Product

6SL3210-1PE32-5AL0

6SL3210-1PE32-5AL0 SIEMENS SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKI..

$0.00USD
4943 in stock
Key Specifications
:SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 110KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 132kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708 X 305 X 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 HF8
EAN:4042948668252
UPC:804766258381
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 110KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 132kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708 X 305 X 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 HF8
EAN4042948668252
UPC804766258381
ETIM5
IDEA4
UNSPSC15
eClass6
Group CodeR220
Date5/4/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorNone
Product Group9775
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85044090
Product familyPower Modules
Net Weight (kg)70,750 Kg
Depth (EF000049)357.0
Width (EF000008)305.0
Country of originGermany
Height (EF000040)708.0
LKZ_FDB/ CatalogIDD11.1SD
Packaging Quantity1
Packaging Dimension469,00 x 745,00 x 385,00
Product DescriptionSINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 110KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 132kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708 X 305 X 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 HF8
Product Lifecycle (PLM)PM300:Active Product
Mains voltage (EF006780)['380', '480']
Export Control RegulationsAL : N / ECCN : 3A999A
Mains frequency (EF006783)-
Standard lead time ex-works30 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
Type of converter (EF006978)U converter
With control unit (EF001538)false
With PC connection (EF006107)-
Max. output voltage (EF009560)-
Max. output frequency (EF007350)550
Number of phases input (EF007117)3
With optical interface (EF003028)-
Number of phases output (EF006998)3
Number of digital inputs (EF001992)-
Degree of protection (IP) (EF005474)IP20
Number of analogue inputs (EF001994)-
Number of digital outputs (EF001993)-
Article Number (Market Facing Number)6SL3210-1PE32-5AL0
Nominal output current I2N (EF009561)250
Number of analogue outputs (EF001995)-
Degree of protection (NEMA) (EF011959)-
Number of HW-interfaces USB (EF003025)-
Supporting protocol for ASI (EF003051)-
Supporting protocol for CAN (EF003053)-
Supporting protocol for KNX (EF003055)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
4-quadrant operation possible (EF006803)false
Number of HW-interfaces other (EF003027)-
Number of interfaces PROFINET (EF006932)-
Integrated breaking resistance (EF007293)true
Number of HW-interfaces RS-232 (EF003021)-
Number of HW-interfaces RS-422 (EF003022)-
Number of HW-interfaces RS-485 (EF003023)-
Supporting protocol for BACnet (EF011944)-
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
Supporting protocol for SUCONET (EF003060)-
Number of HW-interfaces parallel (EF003026)-
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
Number of HW-interfaces serial TTY (EF003024)-
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
Supporting protocol for INTERBUS-Safety (EF006662)-
Application in industrial area permitted (EF007294)true
Relative symmetric net voltage tolerance (EF007453)-10
Supporting protocol for DeviceNet Safety (EF007520)-
Region Specific PriceGroup / Headquarter Price Group339 / 339
Supporting protocol for other bus systems (EF003062)-
Relative symmetric net frequency tolerance (EF007454)5
Number of HW-interfaces industrial Ethernet (EF003020)-
Supporting protocol for Foundation Fieldbus (EF007522)-
Max. output at linear load at rated output voltage (EF007364)110.0
Supporting protocol for AS-Interface Safety at Work (EF007519)-
Max. output at quadratic load at rated output voltage (EF007366)132.0
Application in domestic- and commercial area permitted (EF007295)false
Compliance with the substance restrictions according to RoHS directiveSince: 01.01.2017
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):4,4'-isopropylidenediphenol (Bisphenol A, BPA)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Diboron trioxide CAS-No. 1303-86-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Diboron trioxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Product Description

SINAMICS G120 Power Module PM240-2 with integrated Class A Filter, with integrated Chopper 3AC 380-480V +10/-20% 47-63Hz. High overload power: 110KW with 200% 3s,150% 57s,100% 240s Temp. Amb -20 to +5
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top