| Parameter | Value |
|---|---|
| VersionClassificationeClass627-24-26-07eClass7.127-24-26-07eClass827-24-26-07eClass927-24-26-07eClass9.127-24-26-07ETIM5EC001603ETIM6EC001603ETIM7EC001603ETIM8EC001603IDEA43565UNSPSC1443-20-15-03UNSPSC1532-15-17-05 | |
| EAN | 4025515080312 |
| UPC | 040892826050 |
| ETIM | 5 |
| IDEA | 4 |
| UNSPSC | 14 |
| eClass | 6 |
| Group Code | R152 |
| Metal Factor | None |
| Product Group | 4A86 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85389091 |
| Product family | IM 154-8 F PN/DP CPU |
| Net Weight (kg) | 0,762 Kg |
| Depth (EF000049) | 65.0 |
| Width (EF000008) | 135.0 |
| Country of origin | Germany |
| Height (EF000040) | 130.0 |
| LKZ_FDB/ CatalogID | ST76 |
| Packaging Quantity | 1 |
| Packaging Dimension | 14,40 x 16,10 x 7,60 |
| Product Description | SIMATIC DP, IM154-8FX PN/DP CPU f. ET200 PRO, 1.5 MB work memory, Int. PROFINET interface, Int. PROFIBUS DP master/slave interface Degree of protection IP65/67, Micro Memory Card and Connection module required |
| Product Lifecycle (PLM) | PM300:Active Product |
| IO link master (EF007298) | false |
| Export Control Regulations | AL : N / ECCN : EAR99H |
| Number of slots (EF003077) | 16 |
| Standard lead time ex-works | 35 Day/Days |
| Surcharge for Raw Materials | None |
| System accessory (EF004118) | true |
| Package size unit of measure | CM |
| Radio standard GSM (EF008524) | false |
| Input voltage at DC (EF007120) | ['20.4', '28.8'] |
| Radio standard GPRS (EF008523) | false |
| Radio standard UMTS (EF008525) | false |
| Output voltage at DC (EF007001) | ['-', '-'] |
| Max. input current DC (EF007362) | - |
| Max. output current DC (EF007353) | - |
| Rack-assembly possible (EF007018) | - |
| Rail mounting possible (EF003972) | true |
| Type of output voltage (EF008222) | - |
| With optical interface (EF003028) | false |
| Front build in possible (EF007016) | - |
| Radio standard Bluetooth (EF007178) | false |
| Degree of protection (IP) (EF005474) | IP65/IP67 |
| Input voltage at AC 50 Hz (EF007118) | ['-', '-'] |
| Input voltage at AC 60 Hz (EF007119) | ['-', '-'] |
| With potential separation (EF003272) | true |
| Article Number (Market Facing Number) | 6ES7154-8FX00-0AB0 |
| Output voltage at AC 50 Hz (EF006999) | ['-', '-'] |
| Output voltage at AC 60 Hz (EF007000) | ['-', '-'] |
| Radio standard WLAN 802.11 (EF007179) | false |
| SIL according to IEC 61508 (EF009889) | 3 |
| Max. input current AC 50 Hz (EF007360) | - |
| Max. input current AC 60 Hz (EF007361) | - |
| Number of HW-interfaces USB (EF003025) | 0 |
| Supporting protocol for ASI (EF003051) | false |
| Supporting protocol for CAN (EF003053) | false |
| Supporting protocol for KNX (EF003055) | false |
| Supporting protocol for LON (EF003017) | false |
| Type of electric connection (EF003961) | Plug-in connection |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Max. output current AC 50 Hz (EF007351) | - |
| Max. output current AC 60 Hz (EF007352) | - |
| With integrated power supply (EF003338) | false |
| Number of HW-interfaces other (EF003027) | 0 |
| Number of interfaces PROFINET (EF006932) | 1 |
| Suitable for safety functions (EF001597) | true |
| Wall mounting/direct mounting (EF007020) | true |
| Category according to EN 954-1 (EF006782) | 4 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 1 |
| Supporting protocol for Modbus (EF003057) | true |
| Supporting protocol for SERCOS (EF006657) | false |
| Supporting protocol for TCP/IP (EF003050) | true |
| With pluggable modules, others (EF003083) | true |
| Supporting protocol for SUCONET (EF003060) | false |
| Type of voltage (input voltage) (EF003033) | DC |
| Number of HW-interfaces Wireless (EF006933) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Supporting protocol for INTERBUS (EF003054) | false |
| Supporting protocol for PROFIBUS (EF003052) | true |
| Appendant operation agent (Ex ia) (EF004141) | false |
| Appendant operation agent (Ex ib) (EF004142) | false |
| Explosion safety category for gas (EF003997) | ATEX gas-ex-protection, Cat. 3G |
| Supporting protocol for DeviceNet (EF003059) | false |
| Supporting protocol for PROFIsafe (EF007526) | true |
| Explosion safety category for dust (EF003998) | None |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Supporting protocol for EtherNet/IP (EF007521) | false |
| Supporting protocol for PROFINET IO (EF007525) | true |
| Supporting protocol for SafetyBUS p (EF007527) | false |
| With pluggable modules, digital I/O (EF003078) | true |
| Supporting protocol for Data-Highway (EF003058) | false |
| Supporting protocol for PROFINET CBA (EF007524) | true |
| With pluggable modules, analogue I/O (EF003079) | true |
| Supporting protocol for INTERBUS-Safety (EF006662) | false |
| With pluggable modules, central modules (EF003082) | true |
| Supporting protocol for DeviceNet Safety (EF007520) | false |
| Region Specific PriceGroup / Headquarter Price Group | 241 / 241 |
| Supporting protocol for other bus systems (EF003062) | true |
| Number of HW-interfaces industrial Ethernet (EF003020) | 1 |
| Supporting protocol for Foundation Fieldbus (EF007522) | false |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e |
| With pluggable modules, communication modules (EF003080) | true |
| With bus coupler for modular station connection (EF003990) | true |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false |
| Fieldbus connection over separate bus coupler possible (EF004002) | true |
| With pluggable modules, function and technology modules (EF003081) | true |
| Compliance with the substance restrictions according to RoHS directive | Since: 04.04.2011 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):4,4'-isopropylidenediphenol (Bisphenol A, BPA)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
Technical specifications and performance data
Installation and operation guide