6ES7151-8FB01-0AB0 - 6ES7151-8FB01-0AB0 SIEMENS SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET inter..
In Stock Hot Product

6ES7151-8FB01-0AB0

6ES7151-8FB01-0AB0 SIEMENS SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET inter..

$0.00USD
4509 in stock
Key Specifications
:Value
EAN:4025515078753
UPC:040892692839
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4025515078753
UPC040892692839
ETIM4
IDEA4
I²t0.13 A²·s
Depth75 mm
Width120 mm; DP master module: 35 mm
AlarmsYes
Height119.5 mm
UNSPSC14
eClass6
PhysicsEthernet
— CFCYes; Optional
— FBDYes
— IRTYes
— LADYes
— MRPYes
— SCLYes; Optional
— STLYes
● MPINo
● UDPYes; via integrated PROFINET interface and loadable FBs
IsolatedYes
— DPV1Yes
● TypeSFB
— GRAPHYes; Optional
Group CodeR111
— Inputs2 048 byte
— presetZ 0 to Z 7
● Inputs2 048 byte
● Number256
● STEP 7Yes; V5.5 or higher
● TCP/IPYes; via integrated PROFINET interface and loadable FBs
● preset150 ms
Price Group241
Single stepYes
— Outputs2 048 byte
— RoutingYes; With DP master module
● ForcingYes
● Outputs2 048 byte
● overall12
● presentYes; Ensured by SIMATIC Micro Memory Card (maintenance-free)
AutocrossingYes
Metal FactorNone
Status blockYes; Up to 2 simultaneously
Product Group4A9E
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— HiGraph®Yes; Optional
— supportedYes
● VariablesInputs, outputs, memory bits, DB, times, counters
● as clientYes; via integrated PROFINET interface and loadable FBs
● as serverYes
● retentiveYes; Must be restarted at each restart
● supportedYes
Commodity Code85389091
Interface typePROFINET
Product familyIM 151-8 F PN/DP CPU
last modified:08/28/2020
— adjustableYes
● Size, max.64 kbyte
● Web serverYes
● adjustableYes
● expandableNo
● integrated256 kbyte; For program and data
AutonegotiationYes
Net Weight (kg)0,396 Kg
Weight, approx.320 g; DP master module: Approx. 100 g
— PROFIenergyYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
— SYNC/FREEZEYes
— Send cycles250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
— lower limit0
— upper limit255
● Backup time6 wk; At 40 °C ambient temperature, typically
● Command setsee instruction list
● DescriptionSee S7-300 operation list
● Granularity1 h
● lower limit1 ms
● upper limit6 000 ms
Depth (EF000049)75.0
Firmware versionV3.2
Power loss, typ.5.5 W
Rated value (DC)24 V
Width (EF000008)120.0
— EquidistanceYes
— Inputs, max.2 kbyte
— Number, max.64
● Number, max.1 024; Number range: 1 to 16000
● PROFINET CBAYes
● in AS, slaveNo
● to DP, slaveYes; With DP master module
Country of originGermany
Height (EF000040)119.5
— Outputs, max.2 kbyte
— Shared deviceYes
— Updating timeMinimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data items.
● Plug-in (MMC)Yes
● in AS, masterNo
● to DP, masterYes; With DP master module
● to MPI, slaveNo
LKZ_FDB/ CatalogIDST76
Packaging Quantity1
— Updating times250 µs to 512 ms (depends on operating mode; for more details, refer to Operating Instructions, "Interface Module IM151-8 PN/DP CPU")
● Nesting levels8
● to MPI, masterNo
Data record routingYes; With DP master module
PG/OP communicationYes
Packaging Dimension13,20 x 15,30 x 9,10
Product DescriptionSIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO controller/I-device without battery, MMC required
● Inputs, default128 byte
● Number of ports3; RJ45
● Range of values0 to 2^31 hours (when using SFC 101)
● for maintenanceYes; MT
Diagnostics functionYes
HW functional status01
Inrush current, max.1.8 A; Typical
— Isochronous modeYes; OB 61; only for PROFINET IO
— S7 communicationYes; with loadable FBs
— of which central496
● Block encryptionYes; With S7 block Privacy
● Isochronous modeNo
● Outputs, default128 byte
Isolation tested with500 V DC
Number of breakpoints4
— Data length, max.32 768 byte
● PROFIBUS DP slaveNo
● integrated switchYes
● Bus fault BF (red)Yes; BF-PN
● Forcing, variablesI/O
● Inputs, adjustable2 048 byte
● PROFIBUS DP masterNo
● PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
● Retentivity presetMB 0 to MB 15
● per priority class16
● usable for routing4; max.
IP degree of protectionIP20
Product Lifecycle (PLM)PM300:Active Product
— PG/OP communicationYes
— Prioritized startupYes
● Number/Number range0
● Outputs, adjustable2 048 byte
● Plug-in (MMC), max.8 Mbyte
● Programming packageSTEP 7 V5.5 or higher, Distributed Safety V5.4 SP4
● cyclic transmissionYes
● on Ethernet via NTPYes; As client
Number of blocks (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
for bit operations, typ.0.06 µs
● Group error SF (red)Yes
● ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
● acyclic transmissionYes
IO link master (EF007298)false
for word operations, typ.0.12 µs
— HMI variable updating500 ms
● Number of startup OBs1; OB 100
● Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
● Retentivity availableYes
● User-defined websitesYes
Export Control RegulationsAL : N / ECCN : EAR99H
Number of slots (EF003077)63
— S7 basic communicationYes; I blocks only
— of which in line, max.64
● Number of HTTP clients5
● PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
● Retentivity adjustableYes; via non-retain property on DB
● System functions (SFC)see instruction list
Process diagnostic messagesYes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ
Reverse polarity protectionYes; against destruction
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
System accessory (EF004118)true
— Number of HMI variables200
— Sampling interval, min.500 ms
● Deviation per day, max.10 s; Typ.: 2 s
● Number of entries, max.500
● Status/control variableYes
● Transmission rate, max.100 Mbit/s; full duplex
● User data per job, max.76 byte
Package size unit of measureCM
— of which powerfail-proof100; Only the last 100 entries are retained
● Number of DPV1 alarm OBs3; OB 55, 56, 57
● Number of clock memories8; 1 memory byte
● Number of free cycle OBs1; OB 1
● Number of time alarm OBs1; OB 10
● per priority class, max.32 768 byte; Max. 2048 bytes per block
Radio standard GSM (EF008524)false
from supply voltage 1L+, max.352 mA; 426 mA with DP master module
— Global data communicationNo
● Number of DP slaves, max.32; Per station
● Number of delay alarm OBs2; OB 20, 21
● Number of variables, max.30
● Point-to-point connectionNo
Input voltage at DC (EF007120)['20.4', '28.8']
Product Dimensions (W x L x H)Not available
Radio standard GPRS (EF008523)false
Radio standard UMTS (EF008525)false
● Hardware clock (real-time)Yes
Output voltage at DC (EF007001)['-', '-']
— Number of connections, max.8
— S7 communication, as clientNo
— S7 communication, as serverYes
— User data consistency, max.1 024 byte; with PROFINET I/O
● Number of connections, max.8
● Number of process alarm OBs1; OB 40
● usable for OP communication11
● usable for PG communication11
● usable for S7 communication10; with loadable FBs
Max. input current DC (EF007362)0.352
for backplane bus (5 V DC), max.700 mA
for fixed point arithmetic, typ.0.16 µs
● System function blocks (SFB)see instruction list
● retentive and synchronizableYes
Max. output current DC (EF007353)-
Rack-assembly possible (EF007018)-
Rail mounting possible (EF003972)true
Type of output voltage (EF008222)-
With optical interface (EF003028)false
— User data per submodule, max.1 024 byte
— reserved for OP communication1
— reserved for PG communication1
● Bus activity PROFINET (green)Yes; P1-/P2-/P3-Link
● Length of mounting rail, max.Station width: ≤ 1 m or < 2 m
● additional within an error OB4
Front build in possible (EF007016)-
Number of modules per system, max.63; Centralized
● Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
● Number of isochronous mode OBs1; OB 61; only for PROFINET
Radio standard Bluetooth (EF007178)false
for floating point arithmetic, typ.0.59 µs
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
— of which status variables, max.30
● Number of synchronous error OBs2; OB 121, 122
● total number of instances, max.32
Degree of protection (IP) (EF005474)IP20
Input voltage at AC 50 Hz (EF007118)['-', '-']
Input voltage at AC 60 Hz (EF007119)['-', '-']
With potential separation (EF003272)true
— Data length per connection, max.1 400 byte
— of which control variables, max.14
● Data length per connection, max.1 400 byte
● Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO)
Article Number (Market Facing Number)6ES7151-8FB01-0AB0
Output voltage at AC 50 Hz (EF006999)['-', '-']
Output voltage at AC 60 Hz (EF007000)['-', '-']
Radio standard WLAN 802.11 (EF007179)false
SIL according to IEC 61508 (EF009889)3
— Number of linked PROFIBUS devices16
● Number of functions, master/slave30
● Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
● usable for S7 basic communication10
Max. input current AC 50 Hz (EF007360)-
Max. input current AC 60 Hz (EF007361)-
Number of HW-interfaces USB (EF003025)0
Supporting protocol for ASI (EF003051)false
Supporting protocol for CAN (EF003053)false
Supporting protocol for KNX (EF003055)false
Supporting protocol for LON (EF003017)false
Type of electric connection (EF003961)Screw-/spring clamp connection
WEEE (2012/19/EU) Take-Back ObligationYes
— Of which IO devices with IRT, max.64
Max. output current AC 50 Hz (EF007351)-
Max. output current AC 60 Hz (EF007352)-
With integrated power supply (EF003338)false
— Number of IO Devices per tool, max.8
— Number of incoming interconnections100
— Number of outgoing interconnections100
— Switchover time on line break, typ.200 ms; PROFINET MRP
— reserved for S7 basic communication0
Number of HW-interfaces other (EF003027)0
Number of interfaces PROFINET (EF006932)3
Suitable for safety functions (EF001597)true
Wall mounting/direct mounting (EF007020)true
automatic detection of transmission rateYes
— Activation/deactivation of DP slavesYes
— Number of stations in the ring, max.50
Category according to EN 954-1 (EF006782)4
Number of HW-interfaces RS-232 (EF003021)0
Number of HW-interfaces RS-422 (EF003022)0
Number of HW-interfaces RS-485 (EF003023)0
Supporting protocol for Modbus (EF003057)true
Supporting protocol for SERCOS (EF006657)false
Supporting protocol for TCP/IP (EF003050)true
With pluggable modules, others (EF003083)true
— Activation/deactivation of IO DevicesYes
— adjustable for OP communication, max.11
— adjustable for OP communication, min.1
— adjustable for PG communication, max.11
— adjustable for PG communication, min.1
— adjustable for S7 communication, max.10
● Total of all master/slave connections1 000
Change of IP address at runtime, supportedYes
Supporting protocol for SUCONET (EF003060)false
Type of voltage (input voltage) (EF003033)DC
simultaneously active Alarm-S blocks, max.300
— Data length of all HMI variables, max.2 000 byte
— Device replacement without swap mediumYes
— Number of connectable IO Devices, max.128
Number of HW-interfaces Wireless (EF006933)0
Number of HW-interfaces parallel (EF003026)0
Supporting protocol for INTERBUS (EF003054)false
Supporting protocol for PROFIBUS (EF003052)false
● Setpoint for the CPU communication load50 %
Appendant operation agent (Ex ia) (EF004141)false
Appendant operation agent (Ex ib) (EF004142)false
Explosion safety category for gas (EF003997)ATEX gas-ex-protection, Cat. 3G
Supporting protocol for DeviceNet (EF003059)false
Supporting protocol for PROFIsafe (EF007526)true
● Behavior of the clock following POWER-ONClock continues running after POWER OFF
● Mains/voltage failure stored energy time5 ms
Explosion safety category for dust (EF003998)None
Number of HW-interfaces serial TTY (EF003024)0
— Data length for connection type 01H, max.1 460 byte
— Data length for connection type 11H, max.32 768 byte
● Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
● Monitoring 24 V voltage supply ON (green)Yes
● Number of mounting rails that can be used1
● Number of remote interconnection partners32
Supporting protocol for EtherNet/IP (EF007521)false
Supporting protocol for PROFINET IO (EF007525)true
Supporting protocol for SafetyBUS p (EF007527)false
With pluggable modules, digital I/O (EF003078)true
Power supply to interface (15 to 30 V DC), max.No
Supporting protocol for Data-Highway (EF003058)false
Supporting protocol for PROFINET CBA (EF007524)true
With pluggable modules, analogue I/O (EF003079)true
— adjustable for S7 basic communication, max.10
— adjustable for S7 basic communication, min.0
● User program protection/password protectionYes
— Number of connectable IO Devices for RT, max.128
● User data per job (of which consistent), max.76 byte
Supporting protocol for INTERBUS-Safety (EF006662)false
With pluggable modules, central modules (EF003082)true
Supporting protocol for DeviceNet Safety (EF007520)false
— several passive connections per port, supportedYes
Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
Supporting protocol for other bus systems (EF003062)true
between PROFIBUS DP and all other circuit componentsYes
— Number of IO Controllers with shared device, max.2
Number of HW-interfaces industrial Ethernet (EF003020)1
Supporting protocol for Foundation Fieldbus (EF007522)false
— Data length of all incoming interconnections, max.2 000 byte
— Data length of all outgoing interconnections, max.2 000 byte
● Size of retentive memory for retentive data blocks64 kbyte
— Direct data exchange (slave-to-slave communication)Yes
— Number of IO devices with prioritized startup, max.32
— Transmission frequency: Transmission interval, min.1 ms
Performance level according to EN ISO 13849-1 (EF007399)Level e
With pluggable modules, communication modules (EF003080)true
● Data management on MMC (after last programming), min.10 y
With bus coupler for modular station connection (EF003990)true
external protection for power supply lines (recommendation)2 A min.
● Behavior of the clock following expiry of backup periodClock continues to run with the time at which the power failure occurred
● Number of device-internal and PROFIBUS interconnections500
Supporting protocol for AS-Interface Safety at Work (EF007519)false
● Data length of all incoming connections master/slave, max.4 000 byte
● Data length of all outgoing connections master/slave, max.4 000 byte
Fieldbus connection over separate bus coupler possible (EF004002)true
With pluggable modules, function and technology modules (EF003081)true
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices with IRT and the option "high flexibility"128
Compliance with the substance restrictions according to RoHS directiveSince: 21.05.2010
— Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
● Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
REACH Art. 33 Duty to inform according to the current list of candidates4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):4,4'-isopropylidenediphenol (Bisphenol A, BPA)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
— Number of DP slaves that can be simultaneously activated/deactivated, max.8
— Number of IO Devices that can be simultaneously activated/deactivated, max.8

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top