| Parameter | Value |
|---|---|
| Value | |
| EAN | 4025515074298 |
| UPC | 662643188134 |
| ETIM | 4 |
| IDEA | 4 |
| Depth | 52 mm |
| Width | 30 mm |
| Height | 81 mm |
| UNSPSC | 14 |
| eClass | 6 |
| Group Code | R111 |
| Price Group | 241 |
| Metal Factor | None |
| Product Group | 4206 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85389091 |
| Product family | F-electronic modules relay |
| last modified: | 08/19/2020 |
| Net Weight (kg) | 0,107 Kg |
| Weight, approx. | 90 g |
| Depth (EF000049) | 52.0 |
| Power loss, typ. | 2.1 W |
| Width (EF000008) | 30.0 |
| ● with packing | 2 bit |
| Country of origin | Germany |
| Height (EF000040) | 81.0 |
| LKZ_FDB/ CatalogID | ST76 |
| PLM Effective Date | Product phase-out since: 01.10.2020 |
| Packaging Quantity | 1 |
| ● acc. to EN 954 | 4 |
| ● shielded, max. | 200 m |
| Packaging Dimension | 6,70 x 9,30 x 3,80 |
| Product Description | SIMATIC DP, Electronics module 1F-RO 24 V DC/AC 24..230V/5A, f. ET200S, 30 mm overall width, 1 relay output (2 NO) Output current 5 A, load voltage 24 V DC and 24...230 V AC, Can be used up to Category 4 (EN 954-1)/ SIL3 (IEC61508)/PLE (ISO13849), if control takes place F-DO (e.g. 6ES7138-4FB02-0AB0) F-DQ |
| ● Rated value (DC) | 24 V; Supply via fail-safe output, e.g. of an F-DO |
| ● unshielded, max. | 200 m |
| Type of digital output | Relays |
| — up to 40 °C, max. | 8 A |
| — up to 50 °C, max. | 6 A |
| — up to 60 °C, max. | 5 A; up to max. 24.8 V |
| Product Lifecycle (PLM) | PM300:Active Product |
| Short-circuit protection | No |
| ● between the channels | Yes |
| IO link master (EF007298) | false |
| Number of digital outputs | 1 |
| Output current (EF003202) | 5.0 |
| ● SIL acc. to IEC 61508 | Up to SIL 3 |
| Export Control Regulations | AL : N / ECCN : N |
| Controlling a digital input | Yes |
| Standard lead time ex-works | 1 Day/Days |
| Surcharge for Raw Materials | None |
| System accessory (EF004118) | true |
| Package size unit of measure | CM |
| Supply voltage DC (EF007534) | ['20.4', '28.8'] |
| ● Current per module, max. | 8 A |
| Radio standard GSM (EF008524) | false |
| ● with inductive load, max. | 0.1 Hz |
| ● with resistive load, max. | 2 Hz |
| Product Dimensions (W x L x H) | Not available |
| Radio standard GPRS (EF008523) | false |
| Radio standard UMTS (EF008525) | false |
| ● for signal "1" rated value | 5 A |
| Rack-assembly possible (EF007018) | false |
| Rail mounting possible (EF003972) | true |
| Type of digital output (EF003601) | Relay |
| Type of output voltage (EF008222) | AC/DC |
| With optical interface (EF003028) | false |
| from backplane bus 3.3 V DC, max. | 10 mA |
| Front build in possible (EF007016) | true |
| Supply voltage AC 50 Hz (EF007532) | - |
| Supply voltage AC 60 Hz (EF007533) | - |
| ● Address space per module, max. | 1 byte |
| Number of digital inputs (EF001992) | 0 |
| Radio standard Bluetooth (EF007178) | false |
| Degree of protection (IP) (EF005474) | IP20 |
| Input current at signal 1 (EF001428) | - |
| Number of digital outputs (EF001993) | 1 |
| — Thermal continuous current, max. | 5 A |
| Article Number (Market Facing Number) | 6ES7138-4FR00-0AA0 |
| Permitted voltage at input (EF007554) | ['-', '-'] |
| Radio standard WLAN 802.11 (EF007179) | false |
| SIL according to IEC 61508 (EF009889) | 3 |
| Digital inputs configurable (EF008516) | - |
| Number of HW-interfaces USB (EF003025) | 0 |
| Permitted voltage at output (EF007553) | ['2.0', '264.0'] |
| Supporting protocol for ASI (EF003051) | false |
| Supporting protocol for CAN (EF003053) | false |
| Supporting protocol for KNX (EF003055) | false |
| Supporting protocol for LON (EF003017) | false |
| Type of electric connection (EF003961) | Screw-/spring clamp connection |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Digital outputs configurable (EF008520) | true |
| ● for signal "1" minimum load current | 5 mA |
| Number of HW-interfaces other (EF003027) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Suitable for safety functions (EF001597) | true |
| Time delay at signal exchange (EF002382) | - |
| Wall mounting/direct mounting (EF007020) | true |
| Category according to EN 954-1 (EF006782) | 4 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Supporting protocol for Modbus (EF003057) | false |
| Supporting protocol for SERCOS (EF006657) | false |
| Supporting protocol for TCP/IP (EF003050) | false |
| Voltage type of supply voltage (EF002991) | DC |
| from load voltage L+ (without load), max. | 100 mA; from control voltage |
| Supporting protocol for SUCONET (EF003060) | false |
| Type of voltage (input voltage) (EF003033) | - |
| ● between the channels and backplane bus | Yes |
| Number of HW-interfaces Wireless (EF006933) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Supporting protocol for INTERBUS (EF003054) | false |
| Supporting protocol for PROFIBUS (EF003052) | false |
| ● Status indicator digital output (green) | Yes |
| Appendant operation agent (Ex ia) (EF004141) | false |
| Appendant operation agent (Ex ib) (EF004142) | false |
| Explosion safety category for gas (EF003997) | ATEX gas-ex-protection, Cat. 3G |
| Supporting protocol for DeviceNet (EF003059) | false |
| Supporting protocol for PROFIsafe (EF007526) | true |
| ● Between the channels and load voltage L+ | Yes; between channels and control voltage |
| Explosion safety category for dust (EF003998) | None |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Supporting protocol for EtherNet/IP (EF007521) | false |
| Supporting protocol for PROFINET IO (EF007525) | false |
| Supporting protocol for SafetyBUS p (EF007527) | false |
| ● Performance level according to ISO 13849-1 | e |
| Supporting protocol for Data-Highway (EF003058) | false |
| Supporting protocol for PROFINET CBA (EF007524) | false |
| Supporting protocol for INTERBUS-Safety (EF006662) | false |
| Supporting protocol for DeviceNet Safety (EF007520) | false |
| Supporting protocol for other bus systems (EF003062) | false |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Short-circuit protection, outputs available (EF003203) | false |
| Supporting protocol for Foundation Fieldbus (EF007522) | false |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false |
| Fieldbus connection over separate bus coupler possible (EF004002) | true |
| Compliance with the substance restrictions according to RoHS directive | Since: 31.12.2008 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
Technical specifications and performance data
Installation and operation guide