| Parameter | Value |
|---|---|
| Value | |
| EAN | 4042948494745 |
| UPC | 887621920852 |
| ETIM | 4 |
| IDEA | 4 |
| Notes | Sucessor:Information on product management |
| UNSPSC | 15 |
| eClass | 6 |
| Standard | |
| ● left | 0 mm |
| ● right | 0 mm |
| Group Code | R315 |
| Net weight | 1.9 kg |
| ● C-Tick | No |
| Price Group | 585 |
| Metal Factor | None |
| Peak current | 22.5 A |
| ● at input | via connector set |
| Mounting type | Screw mounting |
| Product Group | 4215 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| ● at output | via connector set |
| Commodity Code | 85049090 |
| MTBF at 40 °C | 500 000 h |
| Output current | |
| Output voltage | |
| Power loss [W] | |
| Product family | DC UPS with capacitors |
| ● CE marking | Yes |
| Display version | |
| Net Weight (kg) | 1,700 Kg |
| SNMP (EF005284) | FALSE |
| ● Rated value | 7 A |
| Charging current | 2 A |
| Depth (EF000049) | 80.0 |
| Product function | |
| Required spacing | |
| Width (EF000008) | 400.0 |
| Country of origin | Germany |
| Height (EF000040) | 80.0 |
| Other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
| Weight (EF000167) | 1900.0 |
| LKZ_FDB/ CatalogID | KT10-PD |
| PLM Effective Date | Product phase-out since: 01.10.2019 |
| Packaging Quantity | 1 |
| ● during storage | -40 ... +70 °C |
| Ambient temperature | |
| Packaging Dimension | 14,00 x 53,00 x 14,00 |
| Product Description | SITOP UPS500P Maintenance free Uninterruptible Power supply With USB interface Basic device 5 kWs input: 24 V DC output: 24 V DC/7 A Degree of protection IP65 |
| Protection class IP | IP65 |
| input voltage range | 22.5 ... 29 V DC |
| ● during operation | 0 ... 55 °C; with natural convection |
| ● during transport | -40 ... +70 °C |
| ● relating to ATEX | - |
| Efficiency in percent | |
| ON-delay time typical | 0.6 s |
| Shipbuilding approval | - |
| ● in buffering mode | 0 ... 7 A |
| Depth of the enclosure | 80 mm |
| Electrical accessories | Connector set |
| Type of energy storage | with capacitors |
| Voltage curve at input | DC |
| Width of the enclosure | 400 mm |
| ● for battery module | - |
| Design of the interface | USB |
| Height of the enclosure | 80 mm |
| Product Lifecycle (PLM) | PM400:Phase Out Started |
| Voltage type (EF000187) | DC |
| ● as approval for USA | - |
| ● in normal operation | 0 ... 7 A |
| Input voltage (EF003840) | ['24', '24'] |
| ● for normal operation | Normal operation: LED green (OK); Lack of buffer standby: LED red (ALARM); Energy storage > 85%: LED green (CAP. > 85%) |
| Output voltage (EF003933) | ['24', '24.7'] |
| Certificate of suitability | |
| Export Control Regulations | AL : N / ECCN : EAR99H |
| Formula for output voltage | 24 V ± 3 % |
| USV- technology (EF005380) | Offline |
| Input connection (EF009726) | - |
| Standard lead time ex-works | 40 Day/Days |
| Surcharge for Raw Materials | None |
| Construction type (EF000767) | - |
| Package size unit of measure | CM |
| Primary frequency (EF009272) | ['-', '-'] |
| Type of interface (EF006977) | USB |
| ● for emitted interference | EN 55022 Class B |
| Overall efficiency (EF009406) | - |
| Supplied active power typical | 168 W |
| Type of electrical connection | Plug-in connection |
| ● for interference immunity | EN 61000-6-2 |
| Output power factor (EF009405) | - |
| Product Dimensions (W x L x H) | Not available |
| Product component PC interface | Yes |
| Secondary frequency (EF009273) | ['-', '-'] |
| Energy content of energy storage | 5 kW.s |
| Output apparent power (EF009898) | - |
| Supply voltage at DC Rated value | 24 V |
| Efficiency in eco-mode (EF009407) | - |
| Output effective power (EF009897) | 168.0 |
| Auto shut down function (EF009276) | - |
| Bridging time full load (EF000428) | 0.35 |
| Number of phases primary (EF009275) | - |
| Operating resource protection class | Class III |
| Article Number (Market Facing Number) | 6EP1933-2NC01 |
| Number of phases secondary (EF009274) | - |
| Reference code acc. to DIN EN 81346-2 | T |
| Output voltage in buffering mode at DC | 24 ... 24.7 V |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● in buffering mode at DC Rated value | 24 V |
| Environmental category acc. to IEC 60721 | Climate class 3K3, 5 … 95% no condensation |
| Potential free switch contact (EF003626) | - |
| adjustable charging current maximum Note | permanently set |
| ● in normal operation at DC Rated value | 24 V |
| Suitable for network-management (EF000432) | false |
| ● for control circuit and status message | - |
| Number of output connections C13 (EF009727) | - |
| Number of output connections C19 (EF009728) | - |
| Galvanic isolation between entrance and outlet | No |
| Design of the mains power cut bridging-connection | 7 A for 49 s or 5 A for 68 s or 3 A for 108 s or 1 A for 351 s |
| Voltage increase time of the output voltage typical | 25 ms |
| Input current at rated input voltage 24 V Rated value | 7 A; + approx. 2 A with empty energy storage (capacitor) |
| Max. voltage distortion output (linear load) (EF009404) | - |
| adjustable response value voltage for buffer connection | permanently set |
| Number of output connections fixed connection (EF009730) | - |
| adjustable response value voltage for buffer connection preset | 22.5 V |
| Product feature of the enclosure housing for side-by-side mounting | No |
| Compliance with the substance restrictions according to RoHS directive | Since: 03.02.2009 |
| ● reverse polarity protection against input voltage polarity reversal | Yes |
| Number of output connections with protective contact (SCHUKO) (EF009729) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| ● at rated output current for rated value of the output current typical | 96.5 % |
| ● reverse polarity protection against energy storage unit polarity reversal | Yes |
Technical specifications and performance data