| Parameter | Value |
|---|---|
| EAN | 4001869183022 |
| UPC | 754554962474 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 64 mm |
| width | 18 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 90 mm |
| Group Code | P310 |
| net weight | 81 g |
| Confirmation | |
| Metal Factor | L-P----- |
| Date5/10/2022 | |
| Product Group | 5527 |
| Product class | B: return restricted, please contact your Siemens partner/contact |
| Quantity Unit | 1 Piece |
| Commodity Code | 85364900 |
| Product family | SENTRON 5TT6 Current Relays |
| Net Weight (kg) | 0,081 Kg |
| Depth (EF000049) | 64.0 |
| Width (EF000008) | 18.0 |
| product function | |
| Country of origin | Germany |
| Height (EF000040) | 90.0 |
| ● initial value | 10 A |
| LKZ_FDB/ CatalogID | LV10.1 |
| Packaging Quantity | 1 |
| product brand name | SENTRON |
| ● plug-in socket | No |
| Packaging Dimension | 37,00 x 93,00 x 75,00 |
| Product Description | overcurrent relay T5570 230V AC 10A 1-phase with transparent cap |
| product designation | Undercurrent relay |
| ● full-scale value | 10 A |
| design of the product | Undercurrent relay |
| Product Lifecycle (PLM) | PM300:Active Product |
| General Product Approval | Declaration of Conformity |
| adjustable OFF-delay time | |
| Export Control Regulations | AL : N / ECCN : N |
| measurable current / at AC | |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| ● overcurrent detection DC | No |
| type of electrical connection | screw-type terminals |
| ● undercurrent detection DC | No |
| control supply voltage / at AC | |
| With detachable clamps (EF003340) | - |
| ● current window recognition DC | No |
| ● overcurrent detection 1 phase | Yes |
| ● overcurrent detection 3 phase | No |
| ● undercurrent detection 1 phase | No |
| ● undercurrent detection 3 phases | No |
| Current measurement range (EF000417) | ['10.0', '10.0'] |
| ● at 50 Hz / rated value / maximum | 230 V |
| ● at 50 Hz / rated value / minimum | 230 V |
| ● at 60 Hz / rated value / maximum | 230 V |
| ● at 60 Hz / rated value / minimum | 230 V |
| Article Number (Market Facing Number) | 5TT6112 |
| Voltage type for actuating (EF008242) | - |
| Type of electric connection (EF003961) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● voltage window recognition 1 phase | No |
| ● voltage window recognition 3 phase | No |
| External current transformer (EF001923) | - |
| Max. permitted off-delay time (EF008191) | - |
| Function DC-current hysteresis (EF003411) | false |
| Min. adjustable off-delay time (EF008192) | - |
| Three-phase hysteresis possible (EF003395) | false |
| Single-phase hysteresis possible (EF003394) | false |
| Three-phase over current possible (EF003408) | false |
| adjustable pickup delay time / initial value | 0.1 s |
| Single-phase over current possible (EF003407) | true |
| Three-phase under current possible (EF003406) | false |
| Single-phase under current possible (EF003405) | false |
| number of CO contacts / for auxiliary contacts | 1 |
| number of NC contacts / for auxiliary contacts | 0 |
| number of NO contacts / for auxiliary contacts | 0 |
| adjustable pickup delay time / full-scale value | 20 s |
| Rated control supply voltage Us at DC (EF003980) | - |
| Contains function DC-voltage over current (EF003410) | false |
| Max. permitted delay-on energization time (EF008189) | - |
| Number of contacts as change-over contact (EF008257) | - |
| Region Specific PriceGroup / Headquarter Price Group | 12F / 1BK |
| Contains function DC-voltage under current (EF003409) | false |
| Min. adjustable delay-on energization time (EF008190) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| Number of contacts as normally open contact (EF008256) | - |
| Number of contacts as normally closed contact (EF008255) | - |
| type of voltage / of the operating voltage / for actuation | AC |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| General Product ApprovalDeclaration of ConformityotherConfirmationUK Declaration of ConformityMiscellaneousConfirmation | General Product Approval |