| Parameter | Value |
|---|---|
| EAN | 4001869251165 |
| UPC | Not available |
| ETIM | 5 |
| IDEA | 4 |
| depth | 55 mm |
| width | 71 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 90 mm |
| Group Code | P310 |
| net weight | 284 g |
| ● maximum | 50 °C |
| ● minimum | 0 °C |
| Confirmation | |
| Date5/9/2022 | |
| Metal Factor | L-P----- |
| Miscellaneous | Confirmation |
| Product Group | 5521 |
| Product class | B: return restricted, please contact your Siemens partner/contact |
| Quantity Unit | 1 Piece |
| recovery time | 500 ms |
| Commodity Code | 85364900 |
| Product family | SENTRON 5TT5 EMERGENCY STOP Modules |
| Net Weight (kg) | 0,295 Kg |
| Depth (EF000049) | 55.0 |
| Model (EF000010) | Other |
| Width (EF000008) | 71.0 |
| product category | basic device |
| Country of origin | Germany |
| Height (EF000040) | 90.0 |
| ● safety switch | Yes |
| LKZ_FDB/ CatalogID | LV10.1 |
| Packaging Quantity | 1 |
| power loss [V∙A] | |
| product brand name | SENTRON |
| ● plug-in socket | No |
| Packaging Dimension | 75,00 x 93,00 x 75,00 |
| Product Description | EMERGENCY OFF relay T55 230V 10A Overall depth 55 mm |
| product designation | Emergency-off relay |
| suitability for use | |
| ● valve monitoring | No |
| design of the product | Mounting depth 55 mm |
| control supply voltage | |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at AC / rated value | 230 V |
| General Product Approval | Declaration of Conformity |
| Release-delay (EF001129) | - |
| Export Control Regulations | AL : N / ECCN : N |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| With start input (EF003342) | true |
| ● as CO contact / at AC-1 | 5 A |
| Evaluation inputs (EF008245) | 3-channel |
| Package size unit of measure | MM |
| ● as NC contact / at AC-15 | 2 A |
| ● as NC contact / at DC-13 | 24 V |
| ● as NO contact / at AC-15 | 3 A |
| ● as NO contact / at DC-13 | 24 V |
| design of input / start input | Yes |
| operating frequency / maximum | 600 1/h |
| type of electrical connection | screw-type terminals |
| ● tactile sensor monitoring | No |
| ● position switch monitoring | Yes |
| With muting function (EF004057) | false |
| ● proximity switch monitoring | No |
| With feedback circuit (EF003343) | true |
| category / according to EN 954-1 | 4 |
| design of input / feedback input | Yes |
| fastening method / rail mounting | Yes |
| Rail mounting possible (EF003972) | - |
| With approval for TÜV (EF004144) | true |
| With detachable clamps (EF003340) | false |
| operating frequency / rated value | 50 Hz |
| product function / muting function | No |
| width of opening / of the contacts | 1 mm |
| With approval for BG BIA (EF004145) | true |
| ● EMERGENCY-OFF circuit monitoring | Yes |
| Article Number (Market Facing Number) | 5TT5200 |
| SIL according to IEC 61508 (EF009889) | None |
| Voltage type for actuating (EF008242) | AC |
| Type of electric connection (EF003961) | Screw connection |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ambient temperature / during operation | |
| With approval according to UL (EF001783) | false |
| Category according to EN 954-1 (EF006782) | 4 |
| number of terminals / with cross-head screw | 1 |
| ● magnetically operated switch monitoring | No |
| Suitable for monitoring of valves (EF007272) | false |
| switching capacity current / of the contacts | |
| switching capacity voltage / of the contacts | |
| type of connectable conductor cross-sections | 2 × 2.5 mm² (rigid max.); 1 × 0.5 mm² (flexible, with end sleeve min.) |
| ● at AC / at 50 Hz / rated value / maximum | 253 V |
| ● at AC / at 50 Hz / rated value / minimum | 184 V |
| ● at AC / at 60 Hz / rated value / maximum | 253 V |
| ● at AC / at 60 Hz / rated value / minimum | 184 V |
| operating range factor / of control voltage_1 | 0.8 |
| operating range factor / of control voltage_2 | 1.1 |
| Stop category according to IEC 60204 (EF007498) | Other |
| type of voltage / of the control supply voltage | AC |
| Rated control supply voltage Us at DC (EF003980) | - |
| ● opto-electronic protection device monitoring | No |
| ● of magnet coil / in relay operating mechanism | 3.5 VA |
| ● of the contact / in relay operating mechanism | 0.8 VA |
| Type of safety according to IEC 61496-1 (EF004105) | - |
| SIL Claim Limit (subsystem) / according to EN 62061 | 3 |
| control current / at connecting terminal Y1 / at DC | 45 mA |
| Region Specific PriceGroup / Headquarter Price Group | 13C / 1BK |
| performance level (PL) / according to EN ISO 13849-1 | Level e |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| Suitable for monitoring of tactile sensors (EF007271) | false |
| control voltage / at connecting terminal Y1 / at AC/DC | 24 V |
| Suitable for monitoring of magnetic switches (EF007266) | false |
| Suitable for monitoring of position switches (EF007270) | true |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e |
| Suitable for monitoring of proximity switches (EF007267) | false |
| Suitable for monitoring of emergency-stop circuits (EF007268) | true |
| Number of outputs, safety related, delayed, with contact (EF003345) | - |
| determinants / for climatic applicability / according to IEC 60068-1 | 0/55/04 |
| required spacing / between contacts of the relay operating mechanism | 3 mm |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | - |
| Number of outputs, safety related, undelayed, with contact (EF003344) | - |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | - |
| Number of outputs, signalling function, delayed, with contact (EF003349) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | false |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | - |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | - |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | - |
| surge voltage resistance / between contacts of the relay operating mechanism | 4 kV |
| amplitude of deflection / for vibration test / according to IEC 60068-2-6 up to 55 Hz | 0.35 mm |
| electrical endurance (switching cycles) / of the contacts / at 2 A / at AC-15 / at 230 V | 100 000 |
| number of outputs / as contact-affected switching element / safety-related / instantaneous contact | 4 |
| General Product ApprovalDeclaration of ConformityotherConfirmationMiscellaneousEnvironmental ConfirmationsotherMiscellaneousConfirmation | General Product Approval |
Technical specifications and performance data