| Parameter | Value |
|---|---|
| Value | |
| EAN | 4001869470665 |
| UPC | Not available |
| Depth | 71 mm |
| Notes | Product is no longer availableSucessor:Further information about local contact: www.siemens.com/lowvoltage/contactIf you need assistance please contact our local Siemens office |
| Width | 70 mm |
| Height | 90 mm |
| Group Code | P310 |
| Price Group | 13C |
| Metal Factor | LHB----- |
| Miscellaneous | |
| Product Group | 5527 |
| Product class | B: return restricted, please contact your Siemens partner/contact |
| Quantity Unit | 1 Piece |
| Commodity Code | 85364900 |
| Product family | Not available |
| Net Weight (kg) | 0,257 Kg |
| Depth (EF000049) | 71.0 |
| Product function | |
| Width (EF000008) | 70.0 |
| Country of origin | Germany |
| Height (EF000040) | 90.0 |
| LKZ_FDB/ CatalogID | LV10.1 |
| PLM Effective Date | Product discontinued since: 31.01.2019 |
| Packaging Quantity | 1 |
| otherMiscellaneous | other |
| product brand name | SENTRON |
| Packaging Dimension | 82,00 x 95,00 x 113,00 |
| Product Description | Voltage and frequency relay for monitoring of line supplies Greater than 30 kVA |
| Product designation | Voltage and frequency relay |
| overvoltage category | 3 |
| ● Full-scale value | 0.1 s |
| Control supply voltage | |
| Product Lifecycle (PLM) | PM490:Start of final year of support |
| adjustable OFF-delay time | |
| Export Control Regulations | ECCN : N / AL : N |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| ● Overvoltage detection DC | No |
| ● undervoltage detection DC | No |
| Product Dimensions (W x L x H) | Not available |
| Type of voltage / for monitoring | AC |
| Response value voltage (EF008193) | ['184', '288'] |
| With detachable clamps (EF003340) | - |
| ● Overvoltage detection 1 phase | Yes |
| ● Overvoltage detection 3 phase | Yes |
| ● Voltage window recognition DC | No |
| ● type of electrical connection | screw-type terminals |
| ● undervoltage detection 1 phase | Yes |
| ● undervoltage detection 3 phases | Yes |
| Article Number (Market Facing Number) | 5TT3427 |
| Voltage type for actuating (EF008242) | - |
| Type of electric connection (EF003961) | Screw connection |
| Voltage measurement range 1 (EF006134) | ['85', '288'] |
| Voltage measurement range 2 (EF006135) | ['-', '-'] |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● Voltage window recognition 1 phase | No |
| ● Voltage window recognition 3 phase | No |
| Max. permitted off-delay time (EF008191) | - |
| adjustable voltage range / initial value | 184 V |
| Min. adjustable off-delay time (EF008192) | - |
| Measurable voltage / at AC / initial value | 85 V |
| Three-phase hysteresis possible (EF003395) | false |
| Single-phase hysteresis possible (EF003394) | false |
| adjustable voltage range / Full-scale value | 288 V |
| ● reference code / acc. to DIN EN 61346-2 | B |
| Contains function DC-over voltage (EF003397) | false |
| Three-phase over voltage possible (EF003393) | true |
| Type of voltage measurement range (EF003399) | AC |
| adjustable pickup delay time / initial value | 0 s |
| ● at AC / at 50 Hz / rated value / maximum | 288 V |
| ● at AC / at 50 Hz / rated value / minimum | 85 V |
| ● at AC / at 60 Hz / rated value / maximum | 288 V |
| ● at AC / at 60 Hz / rated value / minimum | 85 V |
| Contains function DC-under voltage (EF003396) | false |
| Measurable voltage / at AC / Full-scale value | 288 V |
| Single-phase over voltage possible (EF003392) | true |
| Three-phase under voltage possible (EF003391) | true |
| Number of CO contacts / for auxiliary contacts | 3 |
| Number of NC contacts / for auxiliary contacts | 0 |
| Number of NO contacts / for auxiliary contacts | 0 |
| Single-phase under voltage possible (EF003390) | true |
| adjustable pickup delay time / Full-scale value | 600 s |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| Contains function DC-voltage hysteresis (EF003398) | false |
| ● Type of electrical connection / Plug-in socket | No |
| Max. permitted delay-on energization time (EF008189) | - |
| Number of contacts as change-over contact (EF008257) | - |
| Min. adjustable delay-on energization time (EF008190) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['85.0', '288.0'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['85.0', '288.0'] |
| Number of contacts as normally open contact (EF008256) | - |
| Number of contacts as normally closed contact (EF008255) | - |
| Type of voltage / of the operating voltage / for actuation | AC |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2012 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750 | B |
Technical specifications and performance data
Installation and operation guide