Service time: Monday to Friday 9:00-18:00
5SV4647-0KL - 5SV4647-0KL SIEMENS Residual current operated circuit breaker, 4-pole, Type AC, In: 80 A, 300 mA, Un AC: 400..
In Stock Hot Product

5SV4647-0KL

5SV4647-0KL SIEMENS Residual current operated circuit breaker, 4-pole, Type AC, In: 80 A, 300 mA, Un AC: 400..

$0.00USD
3598 in stock
Key Specifications
:Miscellaneous
EAN:4001869430263
UPC:Not available
depth:70 mm
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Miscellaneous
EAN4001869430263
UPCNot available
depth70 mm
width72 mm
height90 mm
Group CodeP310
● maximum12.3 W
● minimum0.75 mm²
Confirmation
Metal FactorL-A-----
Date5/14/2022
Product Group5510
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85362090
Product familyNot available
power loss [W]
Net Weight (kg)0,347 Kg
number of poles4
fastening methodDIN rail (REG)
Country of originGermany
mounting positionany
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
installation depth70 mm
product brand nameSENTRON
product variationsN left
Packaging Dimension97,00 x 78,00 x 85,00
Product DescriptionResidual current operated circuit breaker, 4-pole, Type AC, In: 80 A, 300 mA, Un AC: 400 V, N left
operational current
product designationRCCB
protection class IPIP20, if the distribution board is installed, with connected conductors
Frequency (EF005455)50 Hz
overvoltage categoryIII
design of the productInstantaneous
residual current typeAC
I2t value / permissible110 000 A²·s
Product Lifecycle (PLM)PM300:Active Product
● at AC / rated value80 A
● maximum permissible75 °C
● minimum permissible-40 °C
General Product ApprovalDeclaration of Conformity
Rated current (EF000227)80
Rated voltage (EF000228)400
Built-in depth (EF000218)70.0
Declaration of ConformityTest Certificates
Export Control RegulationsECCN : N / AL : N
Mounting method (EF000003)DIN rail
Number of poles (EF001391)4
switching capacity current
Pollution degree (EF002570)-
Standard lead time ex-works70 Day/Days
Surcharge for Raw MaterialsNone
● at 40 °C / rated value80 A
● at 45 °C / rated value77.57 A
● at 50 °C / rated value74.59 A
● at 55 °C / rated value70.22 A
● at 60 °C / rated value64.47 A
● at 65 °C / rated value57.35 A
● at 70 °C / rated value48.8 A
Package size unit of measureMM
short-circuit current rating10 kA
number of modular width units4
Rated fault current (EF002358)0.3
product feature / silicon-freeYes
Leakage current type (EF002560)AC
Selective protection (EF002561)false
position / of power supply cordtop or bottom
Surge current capacity (EF002564)-
let-through current / permissible7 100 A
With interlocking device (EF007385)true
Degree of protection (IP) (EF005474)IP20
ambient temperature / during storage
tripping fault current / rated value300 mA
Article Number (Market Facing Number)5SV4647-0KL
Rated insulation voltage Ui (EF001366)-
Short-time delayed tripping (EF003604)false
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
switching function / short-term delayedNo
Additional equipment possible (EF008148)true
value range / of the operating frequency50 Hz
● according to IEC 61008-1 / rated value0.8 kA
connectable conductor cross-section / solid
value range / of the supply voltage / at AC230/400 V
tightening torque / with screw-type terminals
value range / of the supply voltage frequency50 Hz
Width in number of modular spacings (EF002950)4
connectable conductor cross-section / stranded
Ambient temperature during operating (EF007515)['-25', '45']
Rated impulse withstand voltage Uimp (EF011980)-
Short-circuit breaking capacity (Icw) (EF002562)10.0
supply voltage / for testing equipment / minimum100 V
Region Specific PriceGroup / Headquarter Price Group194 / 1AI
mechanical service life (switching cycles) / typical10 000
size of installation devices / according to DIN 438801
product extension / installable / supplementary devicesYes
Connectable conductor cross section solid-core (EF007337)['0.75', '35.0']
Connectable conductor cross section multi-wired (EF007343)['0.75', '35.0']
short-circuit current / of series fuse / maximum permissible100 A
Compliance with the substance restrictions according to RoHS directiveSince: 01.06.2006
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● for rated value of the current / at AC / in hot operating state / per pole4.1 W
number of test cycles / for environmental testing / according to IEC 60068-2-3028
General Product ApprovalDeclaration of ConformityConfirmationMiscellaneousUK Declaration of ConformityDeclaration of ConformityTest CertificatesotherRailwayDangerous GoodMiscellaneousMiscellaneousConfirmationVibration and ShockTransport InformationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top