| Parameter | Value |
|---|---|
| Special Test Certificate | |
| EAN | 4001869383927 |
| UPC | 754554960272 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 70 mm |
| width | 54 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 121 mm |
| Group Code | P310 |
| net weight | 502 g |
| ● maximum | 25 mm² |
| ● minimum | 0.75 mm² |
| Confirmation | |
| Date5/4/2022 | |
| Metal Factor | L-O----- |
| ● sealable | Yes |
| Product Group | 5507 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85362010 |
| Product family | Basic Devices |
| reference code | |
| Net Weight (kg) | 0,502 Kg |
| number of poles | 3 |
| product feature | |
| fastening method | on standard mounting rail |
| ● halogen-free | Yes |
| ● silicon-free | Yes |
| Country of origin | Germany |
| mounting position | any |
| operating voltage | |
| product component | |
| LKZ_FDB/ CatalogID | LV10.1 |
| Packaging Quantity | 1 |
| installation depth | 70 mm |
| product brand name | SENTRON |
| Packaging Dimension | 57,00 x 125,00 x 84,00 |
| Product Description | Circuit breaker 10kA, 3-pole, C, 1.6 A according to UL 489-480Y/277V |
| degree of pollution | 3 |
| operational current | |
| product designation | Miniature circuit breakers |
| protection class IP | IP20, with connected conductors, IP 40 in the handle range |
| Frequency (EF000416) | ['50.0', '50.0'] |
| overvoltage category | 3 |
| vibration resistance | 50 m/s² at 25 to 150Hz and 60m/s² at 35Hz (4sec) |
| design of the product | Miniature circuit-breaker 5SJ4 |
| Product Lifecycle (PLM) | PM300:Active Product |
| Voltage type (EF000187) | AC/DC |
| product function / note | Terminal tightening torque for Cu, 60/75°C; 3.5Nm/31lb.in |
| ● at AC / rated value | 1.6 A |
| General Product Approval | Declaration of Conformity |
| Rated current (EF000227) | 1.6 |
| Rated voltage (EF000228) | 400 |
| ● tunnel terminals top | No |
| Built-in depth (EF000218) | 70.0 |
| Declaration of Conformity | Test Certificates |
| suitability for operation | Mechanical engineering / industry |
| ● combined terminal top | Yes |
| Export Control Regulations | AL : N / ECCN : N |
| switching capacity current | |
| Pollution degree (EF002570) | 3 |
| Standard lead time ex-works | 95 Day/Days |
| Surcharge for Raw Materials | None |
| ● according to EN 61346-2 | F |
| ● at 30 °C / rated value | 1.6 A |
| ● at 40 °C / rated value | 1.6 A |
| ● at 45 °C / rated value | 1.6 A |
| ● at 50 °C / rated value | 1.5 A |
| ● at 55 °C / rated value | 1.5 A |
| ● at 60 °C / rated value | 1.4 A |
| ● tunnel terminals bottom | No |
| Package size unit of measure | MM |
| ● according to IEC 81346-2 | F |
| ● combined terminal bottom | Yes |
| number of modular width units | 3 |
| tripping characteristic class | C |
| position / of power supply cord | Any |
| Over voltage category (EF002569) | 3 |
| Current limiting class (EF002568) | - |
| Release characteristic (EF000889) | C |
| ● at DC / rated value / maximum | 60 V |
| Number of poles (total) (EF008618) | 3 |
| product feature / touch protection | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Number of protected poles (EF005548) | 3P |
| ambient temperature / during storage | |
| supply voltage / at AC / rated value | 400 V |
| Article Number (Market Facing Number) | 5SJ4315-7HG42 |
| Rated insulation voltage Ui (EF001366) | 440 |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ambient temperature / during operation | |
| installation environment regarding EMC | Suitable for environment B (immunity to interference not applicable) |
| supply voltage frequency / rated value | 50 Hz |
| ● according to EN 60898 / rated value | 10 kA |
| Additional equipment possible (EF008148) | true |
| type of voltage / of the operating voltage | AC/DC |
| ● according to IEC 60947-2 / rated value | 15 kA |
| Concurrently switching N-neutral (EF005997) | false |
| insulation voltage (Ui) / at AC / rated value | 440 V |
| Width in number of modular spacings (EF002950) | 3 |
| Ambient temperature during operating (EF007515) | ['-25', '55'] |
| Rated impulse withstand voltage Uimp (EF011980) | - |
| product component / neutral conductor switching | No |
| Suitable for flush-mounted installation (EF006573) | false |
| Region Specific PriceGroup / Headquarter Price Group | 14C / 1AE |
| mechanical service life (switching cycles) / typical | 10 000 |
| product extension / installable / supplementary devices | Yes |
| tightening torque / with screw-type terminals / maximum | 3.5 N·m |
| Connectable conductor cross section solid-core (EF007337) | - |
| Connectable conductor cross section multi-wired (EF007343) | - |
| ● at AC / acc. to UL 489 and CSA C22.2 No. 5-02 / maximum | 277 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2008 |
| Rated short-circuit breaking capacity Icn EN 60898 at 230 V (EF009556) | 10.0 |
| Rated short-circuit breaking capacity Icn EN 60898 at 400 V (EF009555) | 10.0 |
| type of voltage supply / at AC / acc. to UL 489 and CSA C22.2 No. 5-02 | 480/277 |
| ● at DC / 2-channel / acc. to UL 489 and CSA C22.2 No. 5-02 / maximum | 125 V |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V (EF009557) | 15.0 |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V (EF009558) | 15.0 |
| ● at DC / single channel / acc. to UL 489 and CSA C22.2 No. 5-02 / maximum | 60 V |
| connectable conductor cross-section / finely stranded / with core end processing | |
| power loss [W] / for rated value of the current / at AC / in hot operating state / per pole | 1.6 W |
| reference code / according to DIN 40719 extended according to IEC 204-2 / according to IEC 750 | F |
| breaking capacity short-circuit current (Icn) / at AC / according to UL 1077 and CSA C22.2 No.235 | 10 kA |
| General Product ApprovalDeclaration of ConformityConfirmationUK Declaration of ConformityDeclaration of ConformityTest CertificatesotherSpecial Test CertificateMiscellaneous | General Product Approval |
Technical specifications and performance data