| Parameter | Value |
|---|---|
| EAN | 4001869451930 |
| UPC | Not available |
| ETIM | 5 |
| Width | 53.4 mm |
| depth | 71.5 mm |
| Height | 99 mm |
| eClass | 6 |
| standard | IEC 61643-11: 2011, EN 61643-11: 2012 |
| Group Code | P310 |
| net weight | 355 g |
| Accessories | 3 x 5SD7488-2 |
| ● maximum | 760 V |
| Metal Factor | L-B----- |
| TOV behavior | |
| Product Group | 5524 |
| Product class | B: return restricted, please contact your Siemens partner/contact |
| Quantity Unit | 1 Piece |
| signal design | Optical, remote signaling contact |
| Commodity Code | 85363090 |
| Product family | Basic devices |
| design of pole | 3 |
| Net Weight (kg) | 0,417 Kg |
| Product version | Surge arrester |
| stripped length | 16 mm |
| fastening method | DIN rail NS 35 |
| protection level | |
| residual voltage | |
| Country of origin | Germany |
| discharge current | |
| operating voltage | 690 V |
| tightening torque | 4.3 ... 4.7 |
| ● Response time | 25 ns |
| ● at (8/20) µs | 15 kA |
| LKZ_FDB/ CatalogID | LV10.1 |
| Packaging Quantity | 1 |
| shock acceleration | 25 gn |
| Degree of pollution | 2 |
| Packaging Dimension | 58,00 x 106,00 x 78,00 |
| Product Description | Surge arrester, Type 2, pluggable protective modules, UC 750V AC, 3-pole, for 4-wire networks (L1, L2, L3, pen), with remote signaling |
| number of SPD ports | 1 |
| product designation | Surge protection device |
| ● at 3 kA / maximum | 2.3 kV |
| ● at 5 kA / maximum | 2.5 kV |
| ● at 10 kA / maximum | 2.7 kV |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at TOV test voltage | 1000 V AC (5 s / withstand mode) |
| ● for rigid conductor | 1.5 ... 35 |
| ● Test Class I, Type 1 | No |
| ● Test Class II, Type 2 | Yes |
| Category type 2 (EF004230) | true |
| Export Control Regulations | AL : N / ECCN : N |
| Max. PV-voltage (EF008795) | - |
| Mounting method (EF000003) | DIN rail (top hat rail) 35 mm |
| ● Test Class III, Type 3 | No |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| material / of the enclosure | PA 6.6 / PBT |
| type of distribution system | TN-C, IT |
| ● 1 phase / at (8/20) µs | 30 kA |
| Construction size (EF002566) | Other |
| Package size unit of measure | MM |
| continuous operating voltage | |
| Nominal voltage AC (EF004220) | - |
| Nominal voltage DC (EF004221) | - |
| type of electrical connection | Screw terminal |
| Integrated backup fuse (EF008797) | false |
| leakage current / according to UL | 10 kA |
| net weight [lb] / according to UL | 0.78 lb |
| ● for finely stranded conductor | 1.5 ... 25 |
| System configuration DC (EF009926) | 0 |
| System configuration IT (EF009927) | 0 |
| System configuration TN (EF009928) | 0 |
| System configuration TT (EF009931) | 0 |
| Signalling at the device (EF004241) | Optic |
| Voltage protection level (EF003525) | - |
| connectable conductor cross-section | |
| designation of the protective paths | L-PEN, L-PE |
| gross weight [lb] / according to UL | 0.86 lb |
| Degree of protection (IP) (EF005474) | IP20 |
| System configuration TN-C (EF009929) | 0 |
| System configuration TN-S (EF009930) | 0 |
| apparent power consumption / maximum | 1 200 mVA |
| relative humidity / during operation | 5 % ... 95 % |
| Article Number (Market Facing Number) | 5SD7483-5 |
| Max. continuous voltage AC (EF004198) | 760 |
| Max. continuous voltage DC (EF004777) | - |
| System configuration other (EF009932) | 0 |
| System configuration TN-C-S (EF009933) | 0 |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| fuse protection type / for T-connector | 100 A AC (gG) |
| short-circuit rating (SCCR) / at 264 V | 25 kA |
| Voltage protection level L-N (EF004236) | - |
| combustibility class according to UL 94 | V0 |
| Voltage protection level N-PE (EF008796) | - |
| With remote signalling contact (EF000422) | true |
| connection type of remote signaling contact | M2 |
| SPD classification / according to EN 61643-11 | |
| fuse protection type / at V-shaped connection | 80 A AC (gG) |
| type of distribution system / according to UL | 3D |
| Max. discharge surge current (8/20) (EF012274) | - |
| design of the thread / of the connection screw | M5 |
| overvoltage category / according to IEC 61010-1 | III |
| adjustable response factor / of tripping current | 1.6 |
| Measured Limiting Voltage (MLV) / between L and L | 4 kV |
| Nominal discharge surge current (8/20) (EF004214) | 30.0 |
| protection class IP / at connection all terminals | IP20 |
| tightening torque / for remote signaling contacts | 0.25 N·m |
| ● at rated value of discharge current / maximum | 2.9 kV |
| Number of conductors (without earthing) (EF001148) | - |
| Short-circuit breaking capacity (Isccr) (EF012627) | 25.0 |
| ambient temperature / during storage and transport | -40 °C ... 80 °C |
| Region Specific PriceGroup / Headquarter Price Group | 12G / 1BK |
| designation of the protective paths / according to UL | L-L, L-G |
| switching function / of the remote signaling contacts | PDT contact |
| installation altitude above sea level / according to UL | 6 562 ft |
| type of surge protective device (SPD) / according to UL | Type 4 SPD for Type 2 applications |
| ● for remote signaling contacts / for rigid conductor | 0.14 ... 1.5 |
| AWG number / as coded connectable conductor cross section | 15 ... 2 |
| installation altitude / at height above sea level / maximum | 2 000 m |
| Measured Limiting Voltage (MLV) / between L and Ground (GND) | 2.5 kV |
| operating voltage / of the remote signaling contacts / at AC | 5 ... 250 |
| Max. conductor cross section flexible (fine-strand) (EF008828) | - |
| operational current / of the remote signaling contacts / at AC | 5 mA ... 1.5 A |
| stripped length / of the cable / for remote signaling contacts | 7 mm |
| Max. conductor cross section solid (solid, stranded) (EF008827) | 35.0 |
| ● for finely stranded conductor / for remote signaling contacts | 0.14 ... 1.5 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.03.2012 |
| operating voltage / of the remote signaling contacts / according to UL | 125 V |
| Maximum Continuous Operating Voltage (MCOV) / between L and Ground (GND) | 750 V |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| vibrational acceleration / at 5 Hz ... 500 Hz / limited to 2,5 h / per axis | 5 gn |
| operational current / of the remote signaling contacts / at AC / according to UL | 1 A |
| AWG number / as coded connectable conductor cross section / according to UL / maximum | 2 |
| AWG number / as coded connectable conductor cross section / according to UL / minimum | 10 |
| AWG number / as coded connectable conductor cross section / for remote signaling contacts / maximum | 16 |
| AWG number / as coded connectable conductor cross section / for remote signaling contacts / minimum | 28 |
| AWG number / as coded connectable conductor cross section / for remote signaling contacts / according to UL / maximum | 14 |
| AWG number / as coded connectable conductor cross section / for remote signaling contacts / according to UL / minimum | 30 |
| Ambient temperature / during operation / minimum permissible ... ambient temperature / during operation / maximum permissible | -40 °C ... 80 °C |
Technical specifications and performance data