Service time: Monday to Friday 9:00-18:00
5SD7443-1 - 5SD7443-1 SIEMENS Combination arrester type 1+2 Requirement class B+C, UC 350V Pluggable protective modules ..
In Stock Hot Product

5SD7443-1

5SD7443-1 SIEMENS Combination arrester type 1+2 Requirement class B+C, UC 350V Pluggable protective modules ..

$0.00USD
3477 in stock
Key Specifications
:
EAN:4001869340548
UPC:804766537974
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4001869340548
UPC804766537974
ETIM5
Width106.9 mm
depth71.5 mm
Height95 mm
eClass6
standardIEC 61643-11: 2011, EN 61643-11: 2012
Group CodeP310
net weight943 g
Accessories3 x 5SD7428-1 + 3 x 5SD7448-1
● maximum350 V
Metal FactorL-P-----
TOV behavior
Product Group5524
Product classB: return restricted, please contact your Siemens partner/contact
Quantity Unit1 Piece
signal designOptical, remote signaling contact
Commodity Code85363090
Product familyBasic devices
design of pole3
Net Weight (kg)1,076 Kg
Product versionArrester combination
stripped length18 mm
fastening methodDIN rail NS 35
protection level
residual voltage
Country of originGermany
discharge current
operating voltage230 V
tightening torque4.3 ... 4.7
● Response time25 ns
● at (8/20) µs25 kA
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
shock acceleration25 gn
Degree of pollution2
Packaging Dimension97,00 x 114,00 x 88,00
Product DescriptionCombination arrester type 1+2 Requirement class B+C, UC 350V Pluggable protective modules 3-pole, 3+0 circuit for TNC systems with remote display
number of SPD ports1
product designationSurge protection device
● finely stranded2.5 ... 25
● at 3 kA / maximum0.9 kV
● at 5 kA / maximum1 kV
size of surge arrester6MW
● at 10 kA / maximum1.2 kV
Product Lifecycle (PLM)PM300:Active Product
● at TOV test voltage415 V AC (5 s / withstand mode) / 457 V AC (120 min / safe failure mode)
● for rigid conductor2.5 ... 35
● Test Class I, Type 1Yes
● Test Class II, Type 2Yes
Category type 2 (EF004230)true
Export Control RegulationsAL : N / ECCN : N
Max. PV-voltage (EF008795)-
Mounting method (EF000003)DIN rail (top hat rail) 35 mm
● Test Class III, Type 3No
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
material / of the enclosurePBT
standards / according to ULUL 1449 edition 4
type of distribution systemTN-C
Construction size (EF002566)6 modular spacing
Package size unit of measureMM
continuous operating voltage
Nominal voltage AC (EF004220)-
Nominal voltage DC (EF004221)-
type of electrical connectionScrew terminal
Integrated backup fuse (EF008797)false
leakage current / according to UL20 kA
net weight [lb] / according to UL2.08 lb
● for finely stranded conductor2.5 ... 25
System configuration DC (EF009926)0
System configuration IT (EF009927)0
System configuration TN (EF009928)0
System configuration TT (EF009931)0
Signalling at the device (EF004241)Optic
Voltage protection level (EF003525)-
connectable conductor cross-section
designation of the protective pathsL-PEN
gross weight [lb] / according to UL2.45 lb
Degree of protection (IP) (EF005474)IP20
System configuration TN-C (EF009929)1
System configuration TN-S (EF009930)0
apparent power consumption / maximum300 mVA
relative humidity / during operation5 % ... 95 %
Article Number (Market Facing Number)5SD7443-1
Max. continuous voltage AC (EF004198)350
Max. continuous voltage DC (EF004777)-
System configuration other (EF009932)0
charge of the flash / at (10/350) µs12.5 A·s
System configuration TN-C-S (EF009933)0
WEEE (2012/19/EU) Take-Back ObligationYes
fuse protection type / for T-connector315 A AC (gG)
short-circuit rating (SCCR) / at 264 V25 kA
Voltage protection level L-N (EF004236)-
combustibility class according to UL 94V0
follow current extinguishing capability25 kA (264 V AC), 3 kA (350 V AC)
Voltage protection level N-PE (EF008796)-
With remote signalling contact (EF000422)true
connection type of remote signaling contactM2 screw thread
SPD classification / according to EN 61643-11
fuse protection type / at V-shaped connection125 A AC (gG)
type of distribution system / according to UL3D
Max. discharge surge current (8/20) (EF012274)-
design of the thread / of the connection screwM5
lightning current peak value / at (10/350) µs25 kA
specific energy of the flash / at (10/350) µs160
overvoltage category / according to IEC 61010-1III
adjustable response factor / of tripping current1.6
Measured Limiting Voltage (MLV) / between L and L2.45 kV
Nominal discharge surge current (8/20) (EF004214)-
protection class IP / at connection all terminalsIP20
tightening torque / for remote signaling contacts0.25 N·m
● at rated value of discharge current / maximum1.5 kV
Number of conductors (without earthing) (EF001148)-
Short-circuit breaking capacity (Isccr) (EF012627)25.0
ambient temperature / during storage and transport-40 °C ... 80 °C
Region Specific PriceGroup / Headquarter Price Group12G / 1BK
designation of the protective paths / according to ULL-L, L-G
switching function / of the remote signaling contactsPDT contact
installation altitude above sea level / according to UL6 562 ft
type of surge protective device (SPD) / according to UL4CA
● for remote signaling contacts / for rigid conductor0.14 ... 1.5
AWG number / as coded connectable conductor cross section13 ... 2
installation altitude / at height above sea level / maximum2 000 m
Measured Limiting Voltage (MLV) / between L and Ground (GND)1.34 kV
operating voltage / of the remote signaling contacts / at AC12 ... 250
Maximum Continuous Operating Voltage (MCOV) / between L and L528 V
Max. conductor cross section flexible (fine-strand) (EF008828)25.0
operational current / of the remote signaling contacts / at AC10 mA ... 1 A
stripped length / of the cable / for remote signaling contacts7 mm
Max. conductor cross section solid (solid, stranded) (EF008827)35.0
response value of the surge voltage / at 6 kV / at (1.2/50) µs1.5 kV
● for finely stranded conductor / for remote signaling contacts0.14 ... 1.5
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
operating voltage / of the remote signaling contacts / according to UL125 V
Maximum Continuous Operating Voltage (MCOV) / between L and Ground (GND)264 V
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
vibrational acceleration / at 5 Hz ... 500 Hz / limited to 2,5 h / per axis5 gn
operational current / of the remote signaling contacts / at AC / according to UL1 A
AWG number / as coded connectable conductor cross section / according to UL / maximum2
AWG number / as coded connectable conductor cross section / according to UL / minimum12
AWG number / as coded connectable conductor cross section / for remote signaling contacts / maximum16
AWG number / as coded connectable conductor cross section / for remote signaling contacts / minimum28
AWG number / as coded connectable conductor cross section / for remote signaling contacts / according to UL / maximum14
AWG number / as coded connectable conductor cross section / for remote signaling contacts / according to UL / minimum30
Ambient temperature / during operation / minimum permissible ... ambient temperature / during operation / maximum permissible-40 °C ... 80 °C

Product Description

Combined unloader, requirement class B and C, types 1 and 2, classes I and II, 3 poles, TN-C nets, 75 kA, 350VAC. Cancelations and returns limited. Consult conditions.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top