Service time: Monday to Friday 9:00-18:00
5SD7422-1 - 5SD7422-1 SIEMENS Surge arrester Type 2 Requirement class C, UC 350V Pluggable protective modules 2-pole, 1+..
In Stock Hot Product

5SD7422-1

5SD7422-1 SIEMENS Surge arrester Type 2 Requirement class C, UC 350V Pluggable protective modules 2-pole, 1+..

$0.00USD
3411 in stock
Key Specifications
:
EAN:4001869340302
UPC:804766156496
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4001869340302
UPC804766156496
ETIM5
Width25.4 mm
depth71.5 mm
Height98 mm
eClass6
standardIEC 61643-11: 2011, EN 61643-11: 2012
Group CodeP310
net weight210 g
Accessories1 x 5SD7428-1 + 1 x 5SD7428-0
● maximum350 V
Metal FactorL-P-----
TOV behavior
Product Group5524
Product classB: return restricted, please contact your Siemens partner/contact
Quantity Unit1 Piece
signal designOptical, remote signaling contact
Commodity Code85363090
Product familyBasic devices
design of pole1+N/PE
Net Weight (kg)0,236 Kg
Product versionSurge arrester
stripped length16 mm
fastening methodDIN rail NS 35
protection level
residual voltage
Country of originGermany
discharge current
operating voltage230 V
tightening torque4.3 ... 4.7
● at (8/20) µs20 kA
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
shock acceleration30 gn
Degree of pollution2
Packaging Dimension94,00 x 22,00 x 80,00
Product DescriptionSurge arrester Type 2 Requirement class C, UC 350V Pluggable protective modules 2-pole, 1+1 circuit for TN-S and TT systems with FRN display, narrow Design
number of SPD ports1
product designationSurge protection device
● between N and L1.4 kV
● finely stranded2.5 ... 16
● between N and PE264 V
— at 2 kA / maximum1 kV
— at 4 kA / maximum1.1 kV
— at 5 kA / maximum1.2 kV
size of surge arrester1,4 MW
— at 10 kA / maximum1.3 kV
Product Lifecycle (PLM)PM300:Active Product
● between L and (PE)N350 V
● for rigid conductor2.5 ... 25
● Test Class I, Type 1No
● Test Class II, Type 2Yes
Category type 2 (EF004230)true
Export Control RegulationsAL : N / ECCN : N
Max. PV-voltage (EF008795)-
Mounting method (EF000003)DIN rail (top hat rail) 35 mm
● Test Class III, Type 3No
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
material / of the enclosurePBT
standards / according to ULUL 1449 edition 4
type of distribution systemTT, TN-S
● 1 phase / at (8/20) µs40 kA
Construction size (EF002566)Other
Package size unit of measureMM
continuous operating voltage
Nominal voltage AC (EF004220)-
Nominal voltage DC (EF004221)-
type of electrical connectionScrew terminal
● at TOV test voltage (L-N)415 V AC (5 s / withstand mode) / 440 V AC (120 min / safe failure mode)
● between PE and N and/or L1.5 kV
● at TOV test voltage (N-PE)1200 V (200 ms / withstand mode)
Integrated backup fuse (EF008797)false
leakage current / according to UL20 kA
net weight [lb] / according to UL0.46 lb
● for finely stranded conductor2.5 ... 16
System configuration DC (EF009926)0
System configuration IT (EF009927)0
System configuration TN (EF009928)0
System configuration TT (EF009931)0
Signalling at the device (EF004241)Optic
Voltage protection level (EF003525)-
connectable conductor cross-section
designation of the protective pathsL-N, N-PE
gross weight [lb] / according to UL0.51 lb
Degree of protection (IP) (EF005474)IP20
System configuration TN-C (EF009929)0
System configuration TN-S (EF009930)0
relative humidity / during operation5 % ... 95 %
● response time / between N and PE100 ns
Article Number (Market Facing Number)5SD7422-1
Max. continuous voltage AC (EF004198)-
Max. continuous voltage DC (EF004777)-
System configuration other (EF009932)0
System configuration TN-C-S (EF009933)0
WEEE (2012/19/EU) Take-Back ObligationYes
fuse protection type / for T-connector315 A AC (gG)
short-circuit rating (SCCR) / at 264 V25 kA
Voltage protection level L-N (EF004236)1.4
combustibility class according to UL 94V0
follow current extinguishing capability
● response time / between L and (PE)N25 ns
Voltage protection level N-PE (EF008796)1.5
With remote signalling contact (EF000422)true
connection type of remote signaling contactM2
SPD classification / according to EN 61643-11
fuse protection type / at V-shaped connection63 A AC (gG)
type of distribution system / according to UL1
Max. discharge surge current (8/20) (EF012274)-
design of the thread / of the connection screwM5
overvoltage category / according to IEC 61010-1III
adjustable response factor / of tripping current1.6
Measured Limiting Voltage (MLV) / between L and N2 kV
Nominal discharge surge current (8/20) (EF004214)40.0
protection class IP / at connection all terminalsIP20
tightening torque / for remote signaling contacts0.25 N·m
— at rated value of discharge current / maximum1.5 kV
Number of conductors (without earthing) (EF001148)-
Short-circuit breaking capacity (Isccr) (EF012627)25.0
ambient temperature / during storage and transport-40 °C ... 80 °C
Region Specific PriceGroup / Headquarter Price Group12G / 1BK
designation of the protective paths / according to ULL-N, L-G, N-G
switching function / of the remote signaling contactsPDT contact
installation altitude above sea level / according to UL6 562 ft
type of surge protective device (SPD) / according to UL4CA
● for remote signaling contacts / for rigid conductor0.14 ... 1.5
AWG number / as coded connectable conductor cross section12 ... 4
installation altitude / at height above sea level / maximum2 000 m
Measured Limiting Voltage (MLV) / between L and Ground (GND)2.08 kV
Measured Limiting Voltage (MLV) / between N and Ground (GND)0.95 kV
operating voltage / of the remote signaling contacts / at AC5 ... 250
Maximum Continuous Operating Voltage (MCOV) / between L and N350 V
Max. conductor cross section flexible (fine-strand) (EF008828)16.0
operational current / of the remote signaling contacts / at AC5 mA ... 1 A
stripped length / of the cable / for remote signaling contacts7 mm
Max. conductor cross section solid (solid, stranded) (EF008827)25.0
response value of the surge voltage / at 6 kV / at (1.2/50) µs
● for finely stranded conductor / for remote signaling contacts0.14 ... 1.5
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
operating voltage / of the remote signaling contacts / according to UL125 V
Maximum Continuous Operating Voltage (MCOV) / between L and Ground (GND)350 V
Maximum Continuous Operating Voltage (MCOV) / between N and Ground (GND)264 V
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
vibrational acceleration / at 5 Hz ... 500 Hz / limited to 2,5 h / per axis5 gn
operational current / of the remote signaling contacts / at AC / according to UL1 A
AWG number / as coded connectable conductor cross section / according to UL / maximum2
AWG number / as coded connectable conductor cross section / according to UL / minimum14
AWG number / as coded connectable conductor cross section / for remote signaling contacts / maximum16
AWG number / as coded connectable conductor cross section / for remote signaling contacts / minimum28
AWG number / as coded connectable conductor cross section / for remote signaling contacts / according to UL / maximum14
AWG number / as coded connectable conductor cross section / for remote signaling contacts / according to UL / minimum30
Ambient temperature / during operation / minimum permissible ... ambient temperature / during operation / maximum permissible-40 °C ... 80 °C

Product Description

Surge discharger, 350 VAC, requirement class C, types 2, class II, 2 poles, TT and TN-S networks, with remote warning. Cancelations and returns limited. Consult conditions.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top