| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209766297 |
| UPC | Not available |
| Depth | 80 mm |
| Notes | Sucessor:Successor portfolio 3VA; further information via www.siemens.com/3VA |
| Group Code | P360 |
| Price Group | 12N |
| ● maximum | 55 °C |
| ● minimum | -40 °C |
| Metal Factor | LCP----- |
| Mounting type | fixed mounting |
| Product Group | 3749 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85362090 |
| Power loss [W] | |
| Product family | Not available |
| Type of device | fixed mounting |
| Net Weight (kg) | 0,994 Kg |
| ● Main switch | Yes |
| ● motor drive | Yes |
| Country of origin | Czech Republic |
| Operating voltage | |
| Product component | |
| mounting position | with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back |
| ● safety switch | No |
| LKZ_FDB/ CatalogID | LV10.1 |
| PLM Effective Date | Product is cancelled since: 01.10.2019 |
| Packaging Quantity | 1 |
| product brand name | SENTRON |
| ● Trip indicator | No |
| Degree of pollution | 3 |
| Packaging Dimension | 102,00 x 135,00 x 84,00 |
| Product Description | switch disconnector 3VT1 3-pole; switch disconnector In=160A rated current without auxiliary release without auxiliary/alarm switch |
| Product designation | 3VT1_5 switch disconnector |
| Protection class IP | IP40 |
| Suitability for use | |
| ● Voltage trigger | No |
| Product Lifecycle (PLM) | PM410:Product cancellation |
| ● at DC / rated value | 250 V |
| ● switch disconnector | Yes |
| General Product Approval | Declaration of Conformity |
| Interlockable (EF006281) | false |
| ● EMERGENCY OFF switch | No |
| ● undervoltage release | No |
| Export Control Regulations | ECCN : N / AL : N |
| Number of poles (EF001391) | 3 |
| Product feature / interlock | No |
| Size of the circuit-breaker | 3VT1 |
| Standard lead time ex-works | 15 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| Product extension / optional | |
| Number of switches (EF005586) | - |
| ● maintenance/repair switch | Yes |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Product Dimensions (W x L x H) | Not available |
| Motor drive optional (EF007386) | true |
| Operating current / rated value | 160 A |
| Color / of the actuating element | black |
| Continuous current / rated value | 160 A |
| Insulation voltage / rated value | 690 V |
| Colour control element (EF007167) | Black |
| Design of the operating mechanism | toggle handle |
| Motor drive integrated (EF006697) | false |
| Version as main switch (EF006981) | true |
| Rated operating voltage (EF001435) | ['415.0', '690.0'] |
| Type of control element (EF006976) | Rocker lever |
| protection class IP / on the front | IP40 |
| Switching power at 400 V (EF009166) | 166.277 |
| Version as safety switch (EF006985) | false |
| Voltage release optional (EF007491) | true |
| Product extension / Auxiliary switch | No |
| Article Number (Market Facing Number) | 3VT1716-2DE36-0AA0 |
| Rated permanent current Iu (EF001389) | 160.0 |
| ● at AC / at 50/60 Hz / rated value | 690 V |
| Ambient temperature / during operation | |
| Degree of protection (NEMA) (EF011959) | - |
| Suitable for floor mounting (EF007243) | FALSE |
| Surge voltage resistance / rated value | 8 kV |
| Version as reversing switch (EF009408) | false |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Operating current / at AC / rated value | 160 A |
| Operating current / at DC / rated value | 160 A |
| Type of the driving mechanism / motor drive | No |
| ● Reference code / acc. to DIN EN 81346-2 | Q |
| ● reference code / acc. to DIN EN 61346-2 | Q |
| Max. rated operation voltage Ue AC (EF007355) | 690 |
| Suitable for front mounting 4-hole (EF007247) | - |
| Suitable for front mounting centre (EF007248) | - |
| Suitable for intermediate mounting (EF007264) | - |
| ● undervoltage release with leading contact | No |
| ● without fuse link / rated value / minimum | 2.83 kA |
| Ambient temperature / during storage / minimum | -40 °C |
| Number of CO contacts / for auxiliary contacts | 0 |
| Number of NC contacts / for auxiliary contacts | 0 |
| Number of NO contacts / for auxiliary contacts | 0 |
| Display version / for switch position indicator | Handle position |
| Rated operation power at AC-3, 400 V (EF001364) | - |
| Degree of protection (IP), front side (EF003118) | IP40 |
| Rated operation power at AC-23, 400 V (EF007027) | - |
| Suitability for integration / Distribution board | Yes |
| Rated short-time withstand current lcw (EF007050) | 2.0 |
| Version as emergency stop installation (EF006959) | false |
| Version as maintenance-/service switch (EF006986) | true |
| Rated permanent current at AC-21, 400 V (EF009165) | 160 |
| Rated permanent current at AC-23, 400 V (EF011777) | - |
| Mechanical service life (switching cycles) / typical | 20 000 |
| Conditioned rated short-circuit current Iq (EF001444) | - |
| Suitable for distribution board installation (EF007262) | - |
| Type of electrical connection / for main current circuit | box terminal |
| Type of electrical connection of main circuit (EF006819) | Frame clamp |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Arrangement of electrical connectors / for main current circuit | front side |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Short-time withstand current (Icw) / limited to 1 s / rated value | 2 kA |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Short-circuit current making capacity (Icm) / for switch disconnector | |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.11.2007 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| ● for rated value of the current / at AC / in hot operating state / per pole | 15 W |
| General Product ApprovalDeclaration of ConformityTest CertificatesotherType Test Certificates/Test ReportMiscellaneousManufacturer Declaration | General Product Approval |
Technical specifications and performance data