Service time: Monday to Friday 9:00-18:00
3VL1710-1DA33-0AA0 - 3VL1710-1DA33-0AA0 SIEMENS circuit breaker VL160X N standard breaking capacity Icu 55kA, 415V AC 3-pole, lin..
In Stock Hot Product

3VL1710-1DA33-0AA0

3VL1710-1DA33-0AA0 SIEMENS circuit breaker VL160X N standard breaking capacity Icu 55kA, 415V AC 3-pole, lin..

$0.00USD
3666 in stock
Key Specifications
:Value
EAN:4011209473102
UPC:Not available
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209473102
UPCNot available
ETIM4
Depth106.5 mm
NotesSucessor:3VA1110-5ED36-....
Width104.5 mm
Height157.5 mm
UNSPSC14
eClass6
● solid2.5 ... 95 mm²
Group CodeP360
Price Group12N
● maximum70 °C
● minimum0 °C
Metal FactorLBO-----
● stranded2.5 ... 95 mm²
Mounting typefixed mounting
Product Group3740
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85362090
Product familyNot available
Usage categoryA
Net Weight (kg)2,213 Kg
number of poles3
● rated value800 V
Product function
Country of originGermany
Operating current
Operating voltage
Product component
Shipping Approvalother
Test CertificatesShipping Approval
Insulation voltage
LKZ_FDB/ CatalogIDLV10.1
PLM Effective DateProduct phase-out since: 01.10.2016
Packaging Quantity1
● Trip indicatorNo
Operating frequency
Packaging Dimension130,00 x 245,00 x 120,00
Product Descriptioncircuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=100A, rated current Ir=100A, overload protection II=1000A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
Protection class IPIP20
suitability for usesystem protection
● 1 / rated value50 Hz
● 2 / rated value60 Hz
● Voltage triggerNo
● Auxiliary switchNo
Product Lifecycle (PLM)PM400:Phase Out Started
● Overload protectionYes
● at AC / rated value800 V
General Product ApprovalEMC
Rated voltage (EF003977)-
Special Test Certificate
● undervoltage releaseNo
● with flexible busbar12 x 10 mm
● rated value / maximum690 V
Export Control RegulationsECCN : EAR99 / AL : N
Number of poles (EF001391)3
certificate of suitabilityIEC, standard switching capacity (N)
● at 240 V / rated value65 kA
● at 415 V / rated value55 kA
● at 440 V / rated value25 kA
● at 500 V / rated value14 kA
● at 690 V / rated value4 kA
Size of the circuit-breaker3VL1
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
● Ground fault protectionNo
● at 40 °C / rated value100 A
● at 50 °C / rated value100 A
● at 55 °C / rated value93 A
● at 60 °C / rated value93 A
● at 65 °C / rated value86 A
● at 70 °C / rated value86 A
Package size unit of measureMM
Operating frequency / maximum120 1/s
Device construction (EF008240)Built-in device fixed built-in technique
Product Dimensions (W x L x H)Not available
Motor drive optional (EF007386)true
Continuous current / rated value100 A
adjustable pick-up value current
Design of the overcurrent releaseTM
Motor drive integrated (EF006697)false
● of thermal overload trip unitfixed
Type of control element (EF006976)-
Rated operational voltage Ue / max.690 V
Ambient temperature / during storage
Degree of protection (IP) (EF005474)IP20
Article Number (Market Facing Number)3VL1710-1DA33-0AA0
Performance class for circuit breakerN
Rated permanent current Iu (EF001389)100.0
With under voltage release (EF007518)false
Ambient temperature / during operation
Surge voltage resistance / rated value8 kV
WEEE (2012/19/EU) Take-Back ObligationYes
With switched-off indicator (EF007006)false
● at 480 V / acc. to NEMA / rated value25 kA
● at 600 V / acc. to NEMA / rated value8 kA
Product extension / optional / motor driveYes
Overload release current setting (EF002336)['100', '100']
Type of the driving mechanism / motor driveNo
● reference code / acc. to DIN EN 61346-2Q
Integrated earth fault protection (EF007296)false
● undervoltage release with leading contactNo
Number of CO contacts / for auxiliary contacts0
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
protection function of the overcurrent releaseLI
● finely stranded / with core end processing2.5 ... 50 mm²
● for main current circuit / at DC / maximum500 V
Complete device with protection unit (EF008906)true
Electrical endurance (switching cycles) / typical10 000
DIN rail (top hat rail) mounting optional (EF008904)true
Mechanical service life (switching cycles) / typical20 000
Maximum short-circuit current breaking capacity (Icu)
Suitable for DIN rail (top hat rail) mounting (EF007250)true
Type of electrical connection / for main current circuitbox terminal
Type of electrical connection of main circuit (EF006819)Frame clamp
Operational short-circuit current breaking capacity (Ics)
● for main current circuit / at AC / at 50 Hz / maximum690 V
● for main current circuit / at AC / at 60 Hz / maximum690 V
Position of connection for main current circuit (EF006671)Front side
Adjustment range undelayed short-circuit release (EF007131)['1000', '1000']
● of instantaneous short-circuit trip unit / initial value1 000 A
● for neutral conductors / Short-circuit and overload proofNo
Number of auxiliary contacts as change-over contact (EF003531)0
Arrangement of electrical connectors / for main current circuitfront side
● of instantaneous short-circuit trip unit / Full-scale value1 000 A
Number of auxiliary contacts as normally open contact (EF001376)0
Type of connectable conductor cross-sections / for main contacts
● of the current-dependent overload release / Full-scale value100 A
Number of auxiliary contacts as normally closed contact (EF001377)0
Adjustment range short-term delayed short-circuit release (EF007129)['-', '-']
Derating temperature / for the rated value of the continuous current50 °C
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048)55.0
Type of connectable conductor cross-sections / for auxiliary contacts
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750Q
adjustable pick-up value current / of the current-dependent overload release / initial value100 A
General Product ApprovalEMCDeclaration of ConformityMiscellaneousTSEKCTest CertificatesShipping ApprovalSpecial Test CertificateShipping ApprovalotherConfirmationEnvironmental ConfirmationsManufacturer DeclarationMiscellaneousGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top