Technical Specifications

ParameterValue
Confirmation
EAN4042948859223
UPC804766318566
ETIM5
IDEA4
Width138 mm
depth110 mm
Height248 mm
UNSPSC15
eClass6
Group CodeP360
Net Weight5.3 kg
depth [in]4.33 in
width [in]5.43 in
height [in]9.76 in
Date5/6/2022
Metal FactorLOA-----
Product Group5383
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
● at 40 °C400 A
● at 45 °C400 A
● at 50 °C400 A
● at 55 °C375 A
● at 60 °C350 A
● at 65 °C325 A
● at 70 °C300 A
Commodity Code85362090
Product family3VA Molded Case Circuit Breakers up to 1000 A, UL / IEC
last modified:11/25/2021
Net Weight (kg)5,300 Kg
Product versionMolded case switch
number of poles3
product function
Country of originCzech Republic
Marine / Shippingother
product component
LKZ_FDB/ CatalogIDLV10
Packaging Quantity1
product brand nameSENTRON
● trip indicatorNo
Packaging Dimension165,00 x 265,00 x 170,00
Product Descriptionmolded case switch 3VA6 UL frame 400 max. sh-circ breaking capacity 100kA @ 480V 3-pole, line protection MCS110, In=400A without overload protection self-protection Ii=14 x In without connection
ambient temperature
operational current
product designationMolded-case circuit breaker
● voltage triggerNo
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalEMC
Rated voltage (EF003977)['600', '600']
power loss [W] / maximum70 W
● undervoltage releaseNo
Export Control RegulationsAL : N / ECCN : EAR99
Number of poles (EF001391)3
● communication functionNo
Standard lead time ex-works20 Day/Days
Surcharge for Raw MaterialsNone
rated insulation voltage Ui800 V
Package size unit of measureMM
● during storage / maximum80 °C
● during storage / minimum-40 °C
Device construction (EF008240)Built-in device fixed built-in technique
● during operation / maximum70 °C
● during operation / minimum-25 °C
● other measurement functionNo
Motor drive optional (EF007386)true
ground-fault monitoring versionWithout
Motor drive integrated (EF006697)false
design of the overcurrent releaseMCS110
Type of control element (EF006976)Rocker lever
protection class IP / on the frontIP40
Degree of protection (IP) (EF005474)IP40
Article Number (Market Facing Number)3VA6340-1BB31-0AA0
Rated permanent current Iu (EF001389)400.0
With under voltage release (EF007518)-
WEEE (2012/19/EU) Take-Back ObligationYes
With switched-off indicator (EF007006)-
reference code / according to IEC 81346-2Q
product designation / according to UL fileCJAE
product extension / optional / motor driveYes
Adjustable response value current / li max.5 600 A
Adjustable response value current / li min.5 600 A
Overload release current setting (EF002336)['-', '-']
Integrated earth fault protection (EF007296)false
Neutral conductors / upgradeable/retrofittableNo
number of CO contacts / for auxiliary contacts0
protection function of the overcurrent releaseI
Complete device with protection unit (EF008906)true
electrical endurance (switching cycles) / at 480 V6 000
electrical endurance (switching cycles) / at 600 V4 200
marking / according to UL 489 / 100%-rated breakerNo
DIN rail (top hat rail) mounting optional (EF008904)true
Region Specific PriceGroup / Headquarter Price Group12P / 1CB
mechanical service life (switching cycles) / typical20 000
Suitable for DIN rail (top hat rail) mounting (EF007250)true
Type of electrical connection of main circuit (EF006819)Other
type of electrical connection / for main current circuitWithout
Ground fault protection / tripping switchable / I2t=ON/OFFNo
Position of connection for main current circuit (EF006671)Other
Adjustment range undelayed short-circuit release (EF007131)['-', '-']
Number of auxiliary contacts as change-over contact (EF003531)0
arrangement of electrical connectors / for main current circuitWithout connection
Number of auxiliary contacts as normally open contact (EF001376)0
Number of auxiliary contacts as normally closed contact (EF001377)0
Adjustment range short-term delayed short-circuit release (EF007129)['-', '-']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048)-
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz4 200
Compliance with the substance restrictions according to RoHS directiveSince: 01.01.2016
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz6 000
certificate of suitability / as approval for NAVAL (no combat vessels) / supplement SBYes
Active power loss / for rated value of the current / at AC / in hot operating state / per pole23.33 W
design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type)Yes
General Product ApprovalConfirmationMiscellaneousGeneral Product ApprovalEMCDeclaration of ConformityMarine / ShippingUK Declaration of ConformityMarine / ShippingotherMiscellaneousMiscellaneousGeneral Product Approval

Product Description

MOLD BOX SWITCH. 3VA6 UL SIZE 400 POWER CUT IN CORTOCIRC. MAX. 100KA @ 480 V 3 POLOS, PROTEC. MCS110 DISTRIBUTIONS, IN=400A WITHOUT PROT. OVERLOAD INTRINSIC PROTECTION II=14 X IN WITHOUT CONNECTION. M
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top