Service time: Monday to Friday 9:00-18:00
3VA5112-6ED31-0AA0 - 3VA5112-6ED31-0AA0 SIEMENS circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, l..
In Stock Hot Product

3VA5112-6ED31-0AA0

3VA5112-6ED31-0AA0 SIEMENS circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, l..

$0.00USD
4258 in stock
Key Specifications
:
KC:Miscellaneous
EAN:4042948841457
UPC:804766301087
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
KCMiscellaneous
EAN4042948841457
UPC804766301087
ETIM5
IDEA4
Width76.2 mm
depth76.5 mm
Height140 mm
UNSPSC15
eClass6
Group CodeP360
Net Weight978 g
depth [in]3.01 in
width [in]3 in
height [in]5.51 in
Metal FactorLOA-----
● at 240 V150 kA
● at 415 V70 kA
● at 480 V65 kA
● at 690 V10 kA
Date5/16/2022
MiscellaneousSpecial Test Certificate
Product Group5385
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
● at 40 °C125 A
● at 45 °C122 A
● at 50 °C119 A
● at 55 °C117 A
● at 60 °C114 A
● at 65 °C112 A
● at 70 °C109 A
Commodity Code85362090
Product family3VA Molded Case Circuit Breakers up to 1000 A, UL / IEC
last modified:10/11/2021
Net Weight (kg)0,978 Kg
Product versionSystem protection
number of poles3
product function
Country of originCzech Republic
Marine / Shippingother
Test CertificatesMarine / Shipping
product component
LKZ_FDB/ CatalogIDLV10
Packaging Quantity1
product brand nameSENTRON
● at 600 Y/347 V25 kA
● trip indicatorNo
Packaging Dimension92,00 x 150,00 x 116,00
Product Descriptioncircuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In without connection
ambient temperature
operational current
product designationMolded-case circuit breaker
● voltage triggerNo
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalEMC
Rated voltage (EF003977)['690', '690']
power loss [W] / maximum30.1 W
● undervoltage releaseNo
breaking capacity current
Export Control RegulationsAL : N / ECCN : EAR99
Number of poles (EF001391)3
● communication functionNo
Standard lead time ex-works9 Day/Days
Surcharge for Raw MaterialsNone
rated insulation voltage Ui800 V
Package size unit of measureMM
● during storage / maximum80 °C
● during storage / minimum-40 °C
Device construction (EF008240)Built-in device fixed built-in technique
● during operation / maximum70 °C
● during operation / minimum-25 °C
● other measurement functionNo
Motor drive optional (EF007386)true
Motor drive integrated (EF006697)false
design of the overcurrent releaseTM210
Type of control element (EF006976)Rocker lever
design of short-circuit protectionFor switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter
protection class IP / on the frontIP40
Degree of protection (IP) (EF005474)IP40
Article Number (Market Facing Number)3VA5112-6ED31-0AA0
Rated permanent current Iu (EF001389)125.0
With under voltage release (EF007518)-
WEEE (2012/19/EU) Take-Back ObligationYes
With switched-off indicator (EF007006)-
Max. rated operational voltage Ue with DC500 V
reference code / according to IEC 81346-2Q
product designation / according to UL fileHEAS
product extension / optional / motor driveYes
Adjustable response value current / lg min.125 A
Overload release current setting (EF002336)['-', '-']
short-circuit current making capacity (Icm)
Integrated earth fault protection (EF007296)false
Neutral conductors / upgradeable/retrofittableNo
number of CO contacts / for auxiliary contacts0
protection function of the overcurrent releaseLI
Complete device with protection unit (EF008906)true
switching capacity class of the circuit breakerH
electrical endurance (switching cycles) / at 480 V8 000
electrical endurance (switching cycles) / at 600 V4 000
marking / according to UL 489 / 100%-rated breakerNo
DIN rail (top hat rail) mounting optional (EF008904)true
Region Specific PriceGroup / Headquarter Price Group12P / 1CB
mechanical service life (switching cycles) / typical20 000
breaking capacity maximum short-circuit current (Icu)
breaking capacity operating short-circuit current (Ics)
Suitable for DIN rail (top hat rail) mounting (EF007250)true
Type of electrical connection of main circuit (EF006819)Other
type of electrical connection / for main current circuitWithout
Ground fault protection / tripping switchable / I2t=ON/OFFNo
Position of connection for main current circuit (EF006671)Other
Adjustment range undelayed short-circuit release (EF007131)['-', '-']
Number of auxiliary contacts as change-over contact (EF003531)0
arrangement of electrical connectors / for main current circuitWithout connection
Number of auxiliary contacts as normally open contact (EF001376)0
Number of auxiliary contacts as normally closed contact (EF001377)0
Adjustment range short-term delayed short-circuit release (EF007129)['-', '-']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048)70.0
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz4 000
Compliance with the substance restrictions according to RoHS directiveSince: 01.01.2016
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz8 000
certificate of suitability / as approval for NAVAL (no combat vessels) / supplement SBNo
design of the load switch / according to UL 489 / Switching Duty circuit breaker (SWD Type)No
Active power loss / for rated value of the current / at AC / in hot operating state / per pole10.03 W
design of the load switch / according to UL 489 / High-Intensity-Discharge circuit breaker (HID Type)No
design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type)Yes
General Product ApprovalConfirmationGeneral Product ApprovalEMCDeclaration of ConformityKCMiscellaneousUK Declaration of ConformityTest CertificatesMarine / ShippingMiscellaneousSpecial Test CertificateMarine / ShippingotherMiscellaneousMiscellaneousGeneral Product Approval

Product Description

AUTOMATIC SWITCH 3VA5 UL size 125 CUTTING POWER CLASS H 65KA @ 480Y/277 V 3 POLES, PROTEC. TM210, FTFM, IN=125A OVERLOAD PROTECTION IR=125A FIXEDLY ADJUSTED SHORT-CIRCUIT PROTECTION II=10 X IN WITHOUT
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top