Service time: Monday to Friday 9:00-18:00
3VA2440-7MQ32-0AA0 - 3VA2440-7MQ32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu 110kA @ 415V 3-p..
In Stock Hot Product

3VA2440-7MQ32-0AA0

3VA2440-7MQ32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu 110kA @ 415V 3-p..

$0.00USD
4747 in stock
Key Specifications
:Confirmation
EAN:4042948830420
UPC:804766431968
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4042948830420
UPC804766431968
ETIM5
IDEA4
Width138 mm
depth110 mm
Height248 mm
UNSPSC14
eClass6
Group CodeP360
Net Weight4.816 kg
depth [in]4.33 in
width [in]5.43 in
height [in]9.76 in
Metal FactorLOA-----
● at 240 V150 kA
● at 415 V110 kA
● at 440 V110 kA
● at 500 V85 kA
● at 690 V6 kA
Date5/12/2022
Product Group5374
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
● at 40 °C400 A
● at 45 °C400 A
● at 50 °C400 A
● at 55 °C400 A
● at 60 °C400 A
● at 65 °C400 A
● at 70 °C400 A
Commodity Code85362090
Product family3VA Molded Case Circuit Breakers up to 1600 A, IEC
last modified:6/11/2021
Net Weight (kg)4,816 Kg
Product versionMotor protection
number of poles3
product function
Country of originCzech Republic
Marine / Shippingother
product component
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
product brand nameSENTRON
● limited to 1 s5 kA
● trip indicatorNo
Packaging Dimension165,00 x 265,00 x 170,00
Product Descriptioncircuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit
ambient temperature
operational current
product designationMolded case circuit breaker
● voltage triggerNo
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalEMC
Rated voltage (EF003977)['690', '690']
power loss [W] / maximum63.5 W
● undervoltage releaseNo
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : EAR99
Number of poles (EF001391)3
● communication functionYes
Standard lead time ex-works20 Day/Days
Surcharge for Raw MaterialsNone
rated insulation voltage Ui800 V
● phase failure detectionYes
Package size unit of measureMM
● during storage / maximum80 °C
● during storage / minimum-40 °C
Courant permanent assigné Iu400 A
Device construction (EF008240)Built-in device fixed built-in technique
● during operation / maximum70 °C
● during operation / minimum-25 °C
● other measurement functionYes
Motor drive optional (EF007386)true
ground-fault monitoring versionSummation current formation L-conductor
Motor drive integrated (EF006697)false
design of the overcurrent releaseETU860M
Type of control element (EF006976)Rocker lever
protection class IP / on the frontIP40
short-time withstand current (Icw)
Degree of protection (IP) (EF005474)IP40
operating power / at AC-3 / at 230 V90 000 W
operating power / at AC-3 / at 400 V160 000 W
Article Number (Market Facing Number)3VA2440-7MQ32-0AA0
Rated permanent current Iu (EF001389)400.0
With under voltage release (EF007518)-
WEEE (2012/19/EU) Take-Back ObligationYes
With switched-off indicator (EF007006)-
reference code / according to IEC 81346-2Q
product extension / optional / motor driveYes
Adjustable response value current / lg max.400 A
Adjustable response value current / lg min.80 A
Adjustable response value current / li max.6 000 A
Adjustable response value current / li min.1 200 A
Overload release current setting (EF002336)['160', '400']
short-circuit current making capacity (Icm)
Integrated earth fault protection (EF007296)true
Neutral conductors / upgradeable/retrofittableNo
number of CO contacts / for auxiliary contacts0
protection function of the overcurrent releaseLSIG
Complete device with protection unit (EF008906)true
switching capacity class of the circuit breakerC
Max. rated operational current of the frame size630 A
DIN rail (top hat rail) mounting optional (EF008904)true
Region Specific PriceGroup / Headquarter Price Group12P / 1CB
mechanical service life (switching cycles) / typical20 000
breaking capacity maximum short-circuit current (Icu)
breaking capacity operating short-circuit current (Ics)
Suitable for DIN rail (top hat rail) mounting (EF007250)true
Type of electrical connection of main circuit (EF006819)Screw connection
type of electrical connection / for main current circuiton both sides nut keeper kit
Ground fault protection / tripping switchable / I2t=ON/OFFYes
Position of connection for main current circuit (EF006671)Front side
Adjustment range undelayed short-circuit release (EF007131)['1200', '6000']
Number of auxiliary contacts as change-over contact (EF003531)0
arrangement of electrical connectors / for main current circuitFront terminal
Number of auxiliary contacts as normally open contact (EF001376)0
Number of auxiliary contacts as normally closed contact (EF001377)0
Adjustment range short-term delayed short-circuit release (EF007129)['480', '6000']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048)110.0
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz3 500
Compliance with the substance restrictions according to RoHS directiveSince: 01.06.2012
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz5 000
Electrical endurance (switching cycles) / at AC-3 / at 380/415 V 50/60 Hz3 000
Type of connectable conductor cross-section, connection screw, width x thickness , max.35 x 10 mm
Type of connectable conductor cross-section, connection screw, width x thickness , min.20 x 1 mm
Active power loss / for rated value of the current / at AC / in hot operating state / per pole21.17 W
General Product ApprovalEMCConfirmationMiscellaneousDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityMiscellaneousSpecial Test CertificateMarine / ShippingotherCCS / China Classification SocietyConfirmationMiscellaneousMiscellaneousGeneral Product Approval

Product Description

AUTOMATIC SWITCH 3VA2 IEC SIZE 630 CUTTING POWER CLASS C ICU=110KA @ 415 V 3 POLES, PROT. MOTORS ETU860M, LSIG, IN=400A OVERLOAD PROTECTION IR=160A ... 400A SHORT CIRCUIT PROTECTION ISD=1.2... 15 X IN
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top