| Parameter | Value |
|---|---|
| Special Test Certificate | |
| EAN | 4042949080497 |
| UPC | 804766889295 |
| ETIM | 5 |
| IDEA | 4 |
| Width | 184 mm |
| depth | 110 mm |
| Height | 248 mm |
| UNSPSC | 15 |
| eClass | 6 |
| Group Code | P360 |
| Net Weight | 6.812 kg |
| depth [in] | 4.33 in |
| width [in] | 7.24 in |
| height [in] | 9.76 in |
| Confirmation | |
| Metal Factor | LOA----- |
| ● at 240 V | 200 kA |
| ● at 415 V | 110 kA |
| ● at 440 V | 110 kA |
| ● at 500 V | 70 kA |
| ● at 690 V | 10 kA |
| Date5/10/2022 | |
| Product Group | 5375 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| ● at 40 °C | 320 A |
| ● at 45 °C | 320 A |
| ● at 50 °C | 320 A |
| ● at 55 °C | 313 A |
| ● at 60 °C | 306 A |
| ● at 65 °C | 299 A |
| ● at 70 °C | 292 A |
| Commodity Code | 85362090 |
| Product family | 3VA Molded Case Circuit Breakers up to 1600 A, IEC |
| last modified: | 10/3/2021 |
| Net Weight (kg) | 6,812 Kg |
| Product version | Line protection |
| number of poles | 4 |
| product function | |
| Country of origin | Czech Republic |
| Marine / Shipping | other |
| LKZ_FDB/ CatalogID | LV10 |
| Packaging Quantity | 1 |
| product brand name | SENTRON |
| Packaging Dimension | 208,00 x 261,00 x 170,00 |
| Product Description | circuit breaker 3VA1 IEC frame 400 breaking capacity class C Icu=110kA @ 415 V 4-pole, line protection TM240, ATAM, In=320A overload protection Ir=224A ...320A short-circuit protection Ii=5...10 x In N conductor protection 1 nut keeper kit |
| ambient temperature | |
| operational current | |
| product designation | Molded case circuit breaker |
| Product Lifecycle (PLM) | PM300:Active Product |
| General Product Approval | EMC |
| Rated voltage (EF003977) | ['690', '690'] |
| power loss [W] / maximum | 80.1 W |
| Declaration of Conformity | Test Certificates |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| Number of poles (EF001391) | 4 |
| ● communication function | No |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| rated insulation voltage Ui | 800 V |
| Package size unit of measure | MM |
| ● during storage / maximum | 80 °C |
| ● during storage / minimum | -40 °C |
| Courant permanent assigné Iu | 320 A |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| ● during operation / maximum | 70 °C |
| ● during operation / minimum | -25 °C |
| ● other measurement function | No |
| Motor drive optional (EF007386) | true |
| ground-fault monitoring version | Without |
| Motor drive integrated (EF006697) | false |
| design of the overcurrent release | TM240 |
| Type of control element (EF006976) | Rocker lever |
| design of short-circuit protection | For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter |
| protection class IP / on the front | IP40 |
| Degree of protection (IP) (EF005474) | IP40 |
| design of the N-conductor protection | 100% |
| Article Number (Market Facing Number) | 3VA1332-7GF42-0AA0 |
| Rated permanent current Iu (EF001389) | 320.0 |
| With under voltage release (EF007518) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| With switched-off indicator (EF007006) | - |
| Max. rated operational voltage Ue with DC | 600 V |
| reference code / according to IEC 81346-2 | Q |
| product extension / optional / motor drive | Yes |
| Adjustable response value current / li max. | 3 200 A |
| Adjustable response value current / li min. | 1 600 A |
| Overload release current setting (EF002336) | ['224', '320'] |
| short-circuit current making capacity (Icm) | |
| Integrated earth fault protection (EF007296) | false |
| Neutral conductors / upgradeable/retrofittable | No |
| number of CO contacts / for auxiliary contacts | 0 |
| protection function of the overcurrent release | LI |
| Complete device with protection unit (EF008906) | true |
| switching capacity class of the circuit breaker | C |
| Max. rated operational current of the frame size | 400 A |
| DIN rail (top hat rail) mounting optional (EF008904) | true |
| Region Specific PriceGroup / Headquarter Price Group | 12P / 1CB |
| mechanical service life (switching cycles) / typical | 20 000 |
| breaking capacity maximum short-circuit current (Icu) | |
| breaking capacity operating short-circuit current (Ics) | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | true |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| type of electrical connection / for main current circuit | nut keeper kit on both ends |
| Ground fault protection / tripping switchable / I2t=ON/OFF | No |
| Position of connection for main current circuit (EF006671) | Front side |
| Adjustment range undelayed short-circuit release (EF007131) | ['1600', '3200'] |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| arrangement of electrical connectors / for main current circuit | Front terminal |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Adjustment range short-term delayed short-circuit release (EF007129) | ['-', '-'] |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | 110.0 |
| Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz | 4 200 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.11.2017 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz | 6 000 |
| design of the surface / of the connections / on the bottom of the switch (N, 2, 4, 6) | Silver |
| Type of connectable conductor cross-section, connection screw, width x thickness , max. | 35 x 10 mm |
| Type of connectable conductor cross-section, connection screw, width x thickness , min. | 20 x 1 mm |
| Active power loss / for rated value of the current / at AC / in hot operating state / per pole | 26.7 W |
| General Product ApprovalEMCDeclaration of ConformityConfirmationMiscellaneousUK Declaration of ConformityDeclaration of ConformityTest CertificatesMarine / ShippingSpecial Test CertificateMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherMiscellaneousMiscellaneous | General Product Approval |
Technical specifications and performance data
Installation and operation guide