Service time: Monday to Friday 9:00-18:00
3VA1163-1AA42-0AA0 - 3VA1163-1AA42-0AA0 SIEMENS switch disconnector 3VA1 IEC frame 160 4-pole SD100, In 63A without overload prot..
In Stock Hot Product

3VA1163-1AA42-0AA0

3VA1163-1AA42-0AA0 SIEMENS switch disconnector 3VA1 IEC frame 160 4-pole SD100, In 63A without overload prot..

$0.00USD
4585 in stock
Key Specifications
:UK Declaration of Conformity
EAN:4042948800553
UPC:804766421976
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
UK Declaration of Conformity
EAN4042948800553
UPC804766421976
ETIM5
Width101.6 mm
depth70 mm
Height130 mm
eClass6
Group CodeP360
Net Weight1.149 kg
Confirmation
Date5/4/2022
Metal FactorLOA-----
Product Group5375
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
● at 40 °C63 A
● at 45 °C63 A
● at 50 °C63 A
● at 55 °C63 A
● at 60 °C63 A
● at 65 °C63 A
● at 70 °C63 A
Commodity Code85362010
Product family3VA Molded Case Circuit Breakers up to 1600 A, IEC
last modified:8/13/2021
Net Weight (kg)1,149 Kg
Product versionin MCCB design
number of poles4
Country of originCzech Republic
Marine / Shippingother
product component
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
product brand nameSENTRON
● trip indicatorNo
Packaging Dimension119,00 x 150,00 x 116,00
Product Descriptionswitch disconnector 3VA1 IEC frame 160 4-pole SD100, In=63A without overload protection w/o short-circuit protection nut keeper kit
ambient temperature
operational current
product designationSwitch disconnector
● voltage triggerNo
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalEMC
Rated voltage (EF003977)-
power loss [W] / maximum38 W
● undervoltage releaseNo
Auxiliary contact versionWithout
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : EAR99
Number of poles (EF001391)-
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
rated insulation voltage Ui800 V
Package size unit of measureMM
● during storage / maximum80 °C
● during storage / minimum-40 °C
Device construction (EF008240)-
● during operation / maximum70 °C
● during operation / minimum-25 °C
Motor drive optional (EF007386)-
design of the auxiliary releasewithout
Motor drive integrated (EF006697)-
Type of control element (EF006976)-
protection class IP / on the frontIP40
Degree of protection (IP) (EF005474)-
Article Number (Market Facing Number)3VA1163-1AA42-0AA0
Rated permanent current Iu (EF001389)-
With under voltage release (EF007518)-
WEEE (2012/19/EU) Take-Back ObligationYes
With switched-off indicator (EF007006)-
Max. rated operational voltage Ue with DC600 V
product function / communication functionNo
reference code / according to IEC 81346-2Q
product extension / optional / motor driveYes
Overload release current setting (EF002336)-
Integrated earth fault protection (EF007296)-
● undervoltage release with leading contactNo
number of CO contacts / for auxiliary contacts0
Complete device with protection unit (EF008906)-
DIN rail (top hat rail) mounting optional (EF008904)-
Region Specific PriceGroup / Headquarter Price Group12P / 1CB
mechanical service life (switching cycles) / typical15 000
Suitable for DIN rail (top hat rail) mounting (EF007250)-
Type of electrical connection of main circuit (EF006819)-
type of electrical connection / for main current circuitbusbar connection
Position of connection for main current circuit (EF006671)-
Adjustment range undelayed short-circuit release (EF007131)-
Number of auxiliary contacts as change-over contact (EF003531)-
arrangement of electrical connectors / for main current circuitFront terminal
Number of auxiliary contacts as normally open contact (EF001376)-
Number of auxiliary contacts as normally closed contact (EF001377)-
Adjustment range short-term delayed short-circuit release (EF007129)-
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048)-
Compliance with the substance restrictions according to RoHS directiveSince: 01.04.2014
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
design of the surface / of the connections / on the top of the switch (N, 1, 3, 5)silver
design of the surface / of the connections / on the bottom of the switch (N, 2, 4, 6)Tin
General Product ApprovalEMCConfirmationMiscellaneousDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformitySpecial Test CertificateMiscellaneousMarine / ShippingotherCCS / China Classification SocietyMiscellaneousMiscellaneousGeneral Product Approval

Product Description

INTERRUPT.-DISCONNECTOR 3VA1 IEC SIZE 160 4 POLES SD100, IN=63A WITHOUT PROTEC. OVERLOAD WITHOUT PROTEC. SHORT CIRCUIT FLAT CONNECTION WITH SCREW. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top