Service time: Monday to Friday 9:00-18:00
3UG5461-1AA40 - 3UG5461-1AA40 SIEMENS DC load monitoring relay for PROFINET, max. 2x8 A / 1x16 A DC, max. 800 V Width: 22.5 ..
In Stock Hot Product

3UG5461-1AA40

3UG5461-1AA40 SIEMENS DC load monitoring relay for PROFINET, max. 2x8 A / 1x16 A DC, max. 800 V Width: 22.5 ..

$0.00USD
4573 in stock
Key Specifications
:VersionClassificationeClass627-37-92-08eClass7.127-37-92-08eClass827-37-92-08eClass927-37-16-92eClass9.127-37-16-92ETIM5EC002586ETIM6EC002586ETIM7EC002586ETIM8EC002586
EAN:4047621064710
UPC:804766977244
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
VersionClassificationeClass627-37-92-08eClass7.127-37-92-08eClass827-37-92-08eClass927-37-16-92eClass9.127-37-16-92ETIM5EC002586ETIM6EC002586ETIM7EC002586ETIM8EC002586
EAN4047621064710
UPC804766977244
ETIM5
depth141.6 mm
width22.5 mm
● 1-8 ... +8 A
● 2-8 ... +8 A
eClass6
height100 mm
● note0.5 A 125 V AC, with resistive load up to 40 °C
— solid1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)
Group CodeR711
— upwards50 mm
● at 24 V1 A
Confirmation
Date5/3/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
— forwards0 mm
— stranded1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)
Product Group4K62
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards50 mm
Commodity Code85364900
Product familyDC load monitoring
last modified:1/12/2021
● auto-RESETYes
Net Weight (kg)0,255 Kg
— at the side0 mm
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
product functionDC load monitoring relay
required spacing
● manual RESETYes
Country of originGermany
mounting positionany
tightening torque
● when starting0 ... 999 s
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
galvanic isolation
insulation voltage
measurable current-8 ... +8 A
product brand nameSIRIUS
● during storage-40 ... +80 °C
● for live parts
Packaging Dimension110,00 x 180,00 x 35,00
Product DescriptionDC load monitoring relay for PROFINET, max. 2x8 A / 1x16 A DC, max. 800 V Width: 22.5 mm Monitoring for violation of upper and lower limit of current, voltage and power; Energy consumption counter, energy recovery counter, switching cycle counter, operating hours counter, warning and alarm thresholds, automatic or manual reset, ON delay 0-999.0 sec, OFF delay 0-999.0 sec, automatic reclosing delay 0-999.0 sec Supply voltage: 24 V DC 1 changeover contact, screw terminal
ambient temperature
product designationDC load monitoring relay
protection class IPIP20
● during operation-25 ... +60 °C
● during transport-40 ... +80 °C
design of the productfor PROFINET
protocol is supported
response time maximum100 ms
● for main contacts
conducted interference
power loss [W] maximum3 W
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalDeclaration of Conformity
adjustable voltage range0 ... 800 V
measurable voltage at DC0 ... 800 V
product type designation3UG5
● PROFINET IO protocolYes
Declaration of Conformity
PROFINET conformity classA
Export Control RegulationsAL : N / ECCN : EAR99
certificate of suitabilityCE
● for auxiliary contacts
Standard lead time ex-works20 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
● between input and outputYes
● overcurrent detection DCYes
● overvoltage detection DCYes
Substance Prohibitance (Date)05/31/2019
electromagnetic compatibilityIEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4
type of electrical connectionscrew-type terminals
● undercurrent detection DCYes
● undervoltage detection DCYes
adjustable response delay time
type of current for monitoringDC
type of voltage for monitoringDC
● with side-by-side mounting
design of the electrical isolationProtective separation
interface design 1 RJ45 (Ethernet)Yes
supply voltage 1 at DC rated value24 V
● at AWG cables for main contacts1x (20 ... 12), 2x (20 ... 14)
number of ports at the 1st interface1
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3UG5461-1AA40
EMC immunity according to IEC 60947-1ambience A (industrial sector)
ampacity of the output relay at DC-13
type of voltage of the supply voltageDC
● Address Resolution Protocol (ARP)Yes
WEEE (2012/19/EU) Take-Back ObligationYes
service for open IE communication LLDPYes
reference code according to IEC 81346-2K
● with lower or upper limit violation0 ... 999 s
network load class according to PROFINET1
● at AWG cables for auxiliary contacts1x (20 ... 12), 2x (20 ... 14)
adjustable current response value current
transmission mode for Industrial EthernetPROFINET with 100 Mbps full duplex (100BASE-TX)
● between control and auxiliary circuit24 V
number of interfaces according to PROFINET1
● between auxiliary and auxiliary circuit24 V
● due to burst according to IEC 61000-4-42 kV
internal resistance of the measuring circuit10 mΩ
number of CO contacts for auxiliary contacts1
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
type of connectable conductor cross-sections
— finely stranded with core end processing1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
maximum permissible voltage for safe isolation
design of the interface Fast Ethernet interfaceYes
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
● for main contacts with screw-type terminals0.6 ... 0.8 N·m
EMC emitted interference according to IEC 60947-1ambience A (industrial sector)
● between the voltage supply and other circuitsYes
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
mechanical service life (switching cycles) typical10 000 000
relative temperature-related measurement deviation0.5 %
field-based interference according to IEC 61000-4-310 V/m
Region Specific PriceGroup / Headquarter Price Group41H / 41H
● for auxiliary contacts with screw-type terminals0.6 ... 0.8 N·m
product component removable terminal for main circuitYes
installation altitude at height above sea level maximum2 000 m
operating range factor supply voltage rated value at DC0.85 ... 1.15
product function at the 1st interface PROFINET IO deviceYes
product function at the Ethernet interface AutocrossoverYes
ampacity for overcurrent duration < 1 s maximum permissible1 A
● due to conductor-earth surge according to IEC 61000-4-52 kV
continuous current of the DIAZED fuse link of the output relay2 A
thermal current of the switching element with contacts maximum1 A
● due to conductor-conductor surge according to IEC 61000-4-51 kV
electrical endurance (switching cycles) for relay outputs maximum100 000
Compliance with the substance restrictions according to RoHS directiveSince: 31.05.2019
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-oneBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● for overvoltage category II according to IEC 60664 with degree of pollution 3 rated value800 V
● for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value600 V
● of the auxiliary and control circuit for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value30 V
General Product ApprovalDeclaration of ConformityTest CertificatesotherConfirmationType Test Certificates/Test ReportConfirmationotherDeclaration of ConformityGeneral Product Approval

Product Description

DC load monitoring relay for PROFINET, max. 2 × 8 A / 1 × 16 A DC, max. 800 V Width: 22.5 mm Overrun monitoring for excess and default of current, voltage and power; energy consumption meter, regenera
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top