Key Specifications
:Type Test Certificates/Test Report
EAN:4011209895829
UPC:040892871821
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Type Test Certificates/Test Report
EAN4011209895829
UPC040892871821
ETIM5
IDEA4
depth91 mm
width22.5 mm
UNSPSC14
eClass6
height92 mm
● solid1x (0.5 ... 4 mm2), 2x (0.5 ... 2.5 mm2)
Group CodeR711
data volume
— upwards0 mm
Confirmation
Date5/2/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
— forwards0 mm
● stranded20 ... 14
Product Group5885
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards0 mm
Commodity Code85364900
Product familyVoltage monitoring
last modified:7/1/2021
● auto-RESETYes
Net Weight (kg)0,147 Kg
type of voltage
— at the side0 mm
● rated value24 V
Depth (EF000049)91.0
Width (EF000008)22.5
fastening methodsnap-on mounting
product functionVoltage monitoring relay
required spacing
Country of originCzech Republic
Height (EF000040)92.0
mounting positionany
● initial value0.75
● when starting0 ... 999.9 s
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
galvanic isolation
product brand nameSIRIUS
● during storage85 ... -40 °C
● external resetYes
● for live parts
● for monitoringAC/DC
Packaging Dimension37,00 x 100,00 x 111,00
Product DescriptionDigital monitoring relay Voltage monitoring, 22.5 mm for IO-Link 10...600 V AC/DC Overvoltage and undervoltage Hysteresis 0.1 to 300 V ON-delay time Tripping delay time 1 change-over contact, screw terminal
ambient temperature
degree of pollution2
product designationVoltage monitoring relay with digital setting
protection class IPIP20
● during operation-25 ... +60 °C
● during transport85 ... -40 °C
● full-scale value1.25
IO-Link transfer rateCOM2 (38,4 kBaud)
design of the displayLCD
conducted interference
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
● at AWG cables solid2x (20 ... 14)
General Product ApprovalEMC
measurable voltage at AC600 ... 10 V
measurable voltage at DC10 ... 600 V
product type designation3UG4
relative repeat accuracy1 %
Declaration of ConformityTest Certificates
measurable line frequency500 ... 40 Hz
● overvoltage detectionYes
Export Control RegulationsAL : N / ECCN : N
● at AWG cables stranded2x (20 ... 14)
● undervoltage detectionYes
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
accuracy of digital display+/-1 digit
relative metering precision5 %
Package size unit of measureMM
control supply voltage at DC
● between input and outputYes
● overvoltage detection DCYes
Substance Prohibitance (Date)05/01/2012
type of electrical connectionscrew-type terminals
● undervoltage detection DCYes
adjustable response delay time
● with side-by-side mounting
Response value voltage (EF008193)['10', '600']
With detachable clamps (EF003340)true
● of the control supply voltageDC
● overvoltage detection 1 phaseYes
● overvoltage detection 3 phaseNo
● voltage window recognition DCYes
design of the electrical isolationProtective separation
● undervoltage detection 1 phaseYes
connectable conductor cross-section
operational current at 17 V minimum10 mA
● undervoltage detection 3 phasesNo
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3UG4832-1AA40
Voltage type for actuating (EF008242)DC
Type of electric connection (EF003961)Screw connection
Voltage measurement range 1 (EF006134)['10', '600']
Voltage measurement range 2 (EF006135)['-', '-']
WEEE (2012/19/EU) Take-Back ObligationYes
protocol is supported IO-Link protocolYes
● voltage window recognition 1 phaseYes
● voltage window recognition 3 phaseNo
number of CO contacts delayed switching1
number of NC contacts delayed switching0
number of NO contacts delayed switching0
reference code according to IEC 81346-2K
● with lower or upper limit violation0 ... 999.9 s
Max. permitted off-delay time (EF008191)999.9
number of poles for main current circuit1
Min. adjustable off-delay time (EF008192)0
● between control and auxiliary circuit690 V
Three-phase hysteresis possible (EF003395)false
● with degree of pollution 2 rated value690 V
Single-phase hysteresis possible (EF003394)true
tightening torque with screw-type terminals1.2 ... 0.8 N·m
● due to burst according to IEC 61000-4-42 kV
Contains function DC-over voltage (EF003397)true
Three-phase over voltage possible (EF003393)false
Type of voltage measurement range (EF003399)AC/DC
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
type of connectable conductor cross-sections
● finely stranded with core end processing1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2)
Contains function DC-under voltage (EF003396)true
Single-phase over voltage possible (EF003392)true
Three-phase under voltage possible (EF003391)false
Single-phase under voltage possible (EF003390)true
maximum permissible voltage for safe isolation
operating frequency with 3RT2 contactor maximum5 000 1/h
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
Rated control supply voltage Us at DC (EF003980)['18', '30']
ampacity of the semiconductor output in SIO mode200 mA
● between the voltage supply and other circuitsYes
Contains function DC-voltage hysteresis (EF003398)true
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
mechanical service life (switching cycles) typical10 000 001
relative temperature-related measurement deviation0.1 %
field-based interference according to IEC 61000-4-310 V/m
type of voltage supply via input/output link masterYes
Max. permitted delay-on energization time (EF008189)999.9
Number of contacts as change-over contact (EF008257)1
Region Specific PriceGroup / Headquarter Price Group41H / 41H
● adjustable open/closed-circuit current principleYes
Min. adjustable delay-on energization time (EF008190)0
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
Number of contacts as normally open contact (EF008256)0
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
Number of contacts as normally closed contact (EF008255)0
● due to conductor-earth surge according to IEC 61000-4-52 kV
continuous current of the DIAZED fuse link of the output relay4 A
thermal current of the switching element with contacts maximum5 A
operating range factor control supply voltage rated value at DC
● due to conductor-conductor surge according to IEC 61000-4-51 kV
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
point-to-point cycle time between master and IO-Link device minimum10 ms
● of the address range of the inputs with cyclical transfer total4 byte
● of the address range of the outputs with cyclical transfer total2 byte
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
insulation voltage for overvoltage category III according to IEC 60664
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesTris(2-chloroethyl) ... CAS-No. 115-96-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Tris(2-chloroethyl) phosphate (TCEP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dicyclohexyl phthala... CAS-No. 84-61-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dicyclohexyl phthalate (DCHP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
General Product ApprovalEMCConfirmationManufacturer DeclarationDeclaration of ConformityTest CertificatesMarine / ShippingotherRailwayType Test Certificates/Test ReportSpecial Test CertificateConfirmationVibration and ShockGeneral Product Approval

Product Description

DIGITAL SURVEILLANCE RELAY VOLTAGE MONITORING, 22.5MM FOR IO-LINK 10 TO 600V AC/DC SUBTENSION AND HYSTERESIS SURGE 0.1 TO 300V TIMING DURING START-UP TO FIRING 1 SWITCH., SCREW TERMINALS
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top