| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4011209642584 |
| UPC | 754554942704 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 91 mm |
| width | 22.5 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 94 mm |
| ● solid | 2x (0.25 ... 1.5 mm²) |
| Group Code | R711 |
| — upwards | 0 mm |
| ● at 24 V | 1 A |
| Date5/2/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | LAO----- |
| — forwards | 0 mm |
| ● at 125 V | 0.2 A |
| ● at 250 V | 0.1 A |
| ● stranded | 24 ... 16 |
| Product Group | 5885 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| — backwards | 0 mm |
| — downwards | 0 mm |
| Commodity Code | 85364900 |
| Product family | Line monitoring |
| last modified: | 12/21/2020 |
| ● auto-RESET | Yes |
| Net Weight (kg) | 0,141 Kg |
| type of voltage | |
| — at the side | 0 mm |
| Depth (EF000049) | 91.0 |
| Width (EF000008) | 22.5 |
| fastening method | snap-on mounting |
| product function | Phase monitoring relay |
| required spacing | |
| Country of origin | Germany |
| Height (EF000040) | 94.0 |
| Test Certificates | Marine / Shipping |
| mounting position | any |
| ● initial value | 1 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| galvanic isolation | |
| product brand name | SIRIUS |
| ● during storage | -40 ... +85 °C |
| ● for live parts | |
| ● for monitoring | AC |
| Packaging Dimension | 29,00 x 99,00 x 107,00 |
| Product Description | Digital monitoring relay 3-phase supply voltage Phase sequence can be activated Phase failure 3 x 160 to 690 V 50 to 60 Hz AC Undervoltage and overvoltage 160-690 V Hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax spring-type connection system |
| ambient temperature | |
| degree of pollution | 3 |
| display version LED | No |
| product designation | Network monitoring relay with digital setting |
| protection class IP | IP20 |
| ● during operation | -25 ... +60 °C |
| ● during transport | -40 ... +85 °C |
| ● full-scale value | 1 |
| design of the display | LCD |
| design of the product | 5 functions |
| conducted interference | |
| ● for grounded parts | |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● asymmetry detection | Yes |
| ● at AWG cables solid | 2x (24 ... 16) |
| ● between the outputs | Yes |
| General Product Approval | EMC |
| measurable voltage at AC | 690 ... 160 V |
| product type designation | 3UG4 |
| relative repeat accuracy | 1 % |
| ● at 250 V at 50/60 Hz | 3 A |
| ● at 400 V at 50/60 Hz | 3 A |
| ● at 50 Hz rated value | 160 ... 690 V |
| ● at 60 Hz rated value | 160 ... 690 V |
| ● overvoltage detection | Yes |
| Export Control Regulations | AL : N / ECCN : N |
| ● at AWG cables stranded | 2x (24 ... 16) |
| ● undervoltage detection | Yes |
| Standard lead time ex-works | 20 Day/Days |
| Surcharge for Raw Materials | None |
| accuracy of digital display | +/-1 digit |
| relative metering precision | 5 % |
| ● phase failure detection | Yes |
| Package size unit of measure | MM |
| control supply voltage at AC | |
| ● between input and output | Yes |
| Substance Prohibitance (Date) | 05/01/2012 |
| type of electrical connection | spring-loaded terminals |
| adjustable response delay time | |
| ● phase sequence recognition | Yes |
| ● with side-by-side mounting | |
| With detachable clamps (EF003340) | true |
| ● of the control supply voltage | AC |
| ● overvoltage detection 3 phase | Yes |
| Phase failure detection (EF003413) | true |
| Type Test Certificates/Test Report | Special Test Certificate |
| Voltage measuring range (EF002486) | ['160', '690'] |
| connectable conductor cross-section | |
| operational current at 17 V minimum | 5 mA |
| ● undervoltage detection 3 phases | Yes |
| Phase sequence monitoring (EF003412) | true |
| surge voltage resistance rated value | 6 kV |
| Article Number (Market Facing Number) | 3UG4615-2CR20 |
| Phase imbalance monitoring (EF003416) | true |
| Voltage type for actuating (EF008242) | AC |
| ampacity of the output relay at AC-15 | |
| ampacity of the output relay at DC-13 | |
| Type of electric connection (EF003961) | Spring clamp connection |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● voltage window recognition 3 phase | Yes |
| number of CO contacts delayed switching | 2 |
| number of NC contacts delayed switching | 0 |
| number of NO contacts delayed switching | 0 |
| reference code according to IEC 81346-2 | K |
| ● with lower or upper limit violation | 0.1 ... 20 s |
| Max. permitted off-delay time (EF008191) | 20 |
| number of poles for main current circuit | 3 |
| Min. adjustable off-delay time (EF008192) | 0.1 |
| Function over voltage detection (EF003415) | true |
| ● with degree of pollution 3 rated value | 690 V |
| Function under voltage detection (EF003414) | true |
| ● due to burst according to IEC 61000-4-4 | 2 kV |
| shock resistance according to IEC 60068-2-27 | sinusoidal half-wave 15g / 11 ms |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 2 x (0.25 ... 1.5 mm²) |
| operating frequency with 3RT2 contactor maximum | 5 000 1/h |
| vibration resistance according to IEC 60068-2-6 | 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g |
| ● finely stranded without core end processing | 2x (0.25 ... 1.5 mm²) |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| ● between the voltage supply and other circuits | Yes |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| mechanical service life (switching cycles) typical | 10 000 000 |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| Max. permitted delay-on energization time (EF008189) | - |
| Number of contacts as change-over contact (EF008257) | 2 |
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H |
| ● adjustable open/closed-circuit current principle | Yes |
| Min. adjustable delay-on energization time (EF008190) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['160.0', '690.0'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['160.0', '690.0'] |
| Number of contacts as normally open contact (EF008256) | 0 |
| AWG number as coded connectable conductor cross section | |
| installation altitude at height above sea level maximum | 2 000 m |
| Number of contacts as normally closed contact (EF008255) | 0 |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| continuous current of the DIAZED fuse link of the output relay | 4 A |
| thermal current of the switching element with contacts maximum | 5 A |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| electrical endurance (switching cycles) at AC-15 at 230 V typical | 100 000 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| insulation voltage for overvoltage category III according to IEC 60664 | |
| product component removable terminal for auxiliary and control circuit | Yes |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| operating range factor control supply voltage rated value at AC at 50 Hz | |
| operating range factor control supply voltage rated value at AC at 60 Hz | |
| General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherRailwayType Test Certificates/Test ReportSpecial Test CertificateConfirmationVibration and Shock | General Product Approval |
Technical specifications and performance data
Installation and operation guide