Service time: Monday to Friday 9:00-18:00
3UG4511-1BP20 - 3UG4511-1BP20 SIEMENS Analog monitoring relay Phase sequence monitoring 3 x 320...500 V 50...60 Hz AC 2 chan..
In Stock Hot Product

3UG4511-1BP20

3UG4511-1BP20 SIEMENS Analog monitoring relay Phase sequence monitoring 3 x 320...500 V 50...60 Hz AC 2 chan..

$0.00USD
4021 in stock
Key Specifications
:VersionClassificationeClass627-37-18-03eClass7.127-37-18-03eClass827-37-18-03eClass927-37-18-03eClass9.127-37-18-03ETIM5EC001441ETIM6EC001441ETIM7EC001441ETIM8EC001441IDEA44727UNSPSC1439-12-15-21UNSPSC1539-12-15-21
EAN:4011209642225
UPC:754554931432
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
VersionClassificationeClass627-37-18-03eClass7.127-37-18-03eClass827-37-18-03eClass927-37-18-03eClass9.127-37-18-03ETIM5EC001441ETIM6EC001441ETIM7EC001441ETIM8EC001441IDEA44727UNSPSC1439-12-15-21UNSPSC1539-12-15-21
EAN4011209642225
UPC754554931432
ETIM5
IDEA4
depth91 mm
width22.5 mm
UNSPSC14
eClass6
height92 mm
● solid1x (0.5 ... 4 mm2), 2x (0.5 ... 2.5 mm2)
Group CodeR711
— upwards0 mm
● at 24 V1 A
Confirmation
Date5/4/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
— forwards0 mm
● at 125 V0.2 A
● at 250 V0.1 A
● stranded20 ... 14
Product Group5885
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards0 mm
Commodity Code85364900
Product familyLine monitoring
last modified:12/21/2020
● auto-RESETYes
Net Weight (kg)0,134 Kg
type of voltage
— at the side0 mm
Depth (EF000049)91.0
Width (EF000008)22.5
fastening methodsnap-on mounting
product functionPhase monitoring relay
required spacing
Country of originGermany
Height (EF000040)92.0
Test CertificatesMarine / Shipping
mounting positionany
● initial value1
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
galvanic isolation
product brand nameSIRIUS
● during storage-40 ... +85 °C
● for live parts
● for monitoringAC
Packaging Dimension29,00 x 99,00 x 107,00
Product DescriptionAnalog monitoring relay Phase sequence monitoring 3 x 320...500 V 50...60 Hz AC 2 change-over contacts screw terminal Successor product for 3UG3511-1BQ50
ambient temperature
degree of pollution3
display version LEDYes
product designationNetwork monitoring relay with analog setting
protection class IPIP20
● during operation-25 ... +60 °C
● during transport-40 ... +85 °C
● full-scale value1
design of the product1 function
conducted interference
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
● asymmetry detectionNo
● at AWG cables solid2x (20 ... 14)
● between the outputsYes
General Product ApprovalEMC
Special Test CertificateType Test Certificates/Test Report
measurable voltage at AC500 ... 320 V
product type designation3UG4
● at 250 V at 50/60 Hz3 A
● at 400 V at 50/60 Hz3 A
● at 50 Hz rated value320 ... 500 V
● at 60 Hz rated value320 ... 500 V
● overvoltage detectionNo
Export Control RegulationsAL : N / ECCN : N
● at AWG cables stranded2x (20 ... 14)
● undervoltage detectionNo
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
● phase failure detectionNo
Package size unit of measureMM
control supply voltage at AC
● between input and outputYes
Substance Prohibitance (Date)05/01/2012
type of electrical connectionscrew-type terminals
● phase sequence recognitionYes
● with side-by-side mounting
With detachable clamps (EF003340)true
● of the control supply voltageAC
● overvoltage detection 3 phaseNo
Phase failure detection (EF003413)false
Voltage measuring range (EF002486)['320', '500']
connectable conductor cross-section
operational current at 17 V minimum5 mA
● undervoltage detection 3 phasesNo
Phase sequence monitoring (EF003412)true
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3UG4511-1BP20
Phase imbalance monitoring (EF003416)false
Voltage type for actuating (EF008242)AC
ampacity of the output relay at AC-15
ampacity of the output relay at DC-13
Type of electric connection (EF003961)Screw connection
WEEE (2012/19/EU) Take-Back ObligationYes
● voltage window recognition 3 phaseNo
number of CO contacts delayed switching2
number of NC contacts delayed switching0
number of NO contacts delayed switching0
reference code according to IEC 81346-2K
Max. permitted off-delay time (EF008191)-
number of poles for main current circuit3
Min. adjustable off-delay time (EF008192)-
Function over voltage detection (EF003415)false
● with degree of pollution 3 rated value690 V
Function under voltage detection (EF003414)false
tightening torque with screw-type terminals0.8 ... 1.2 N·m
● due to burst according to IEC 61000-4-42 kV
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
type of connectable conductor cross-sections
● finely stranded with core end processing1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2)
operating frequency with 3RT2 contactor maximum5 000 1/h
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
Rated control supply voltage Us at DC (EF003980)['-', '-']
● between the voltage supply and other circuitsYes
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
mechanical service life (switching cycles) typical10 000 000
field-based interference according to IEC 61000-4-310 V/m
Max. permitted delay-on energization time (EF008189)-
Number of contacts as change-over contact (EF008257)2
Region Specific PriceGroup / Headquarter Price Group41H / 41H
● adjustable open/closed-circuit current principleNo
Min. adjustable delay-on energization time (EF008190)-
Rated control supply voltage Us at AC 50HZ (EF003978)['320.0', '500.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['320.0', '500.0']
Number of contacts as normally open contact (EF008256)0
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
Number of contacts as normally closed contact (EF008255)0
● due to conductor-earth surge according to IEC 61000-4-52 kV
continuous current of the DIAZED fuse link of the output relay4 A
thermal current of the switching element with contacts maximum5 A
● due to conductor-conductor surge according to IEC 61000-4-51 kV
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
insulation voltage for overvoltage category III according to IEC 60664
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidates4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):4,4'-isopropylidenediphenol (Bisphenol A, BPA)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value at AC at 50 Hz
operating range factor control supply voltage rated value at AC at 60 Hz
General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherRailwaySpecial Test CertificateType Test Certificates/Test ReportConfirmationVibration and ShockGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top