| Parameter | Value |
|---|---|
| EAN | 4011209665323 |
| UPC | 804766053207 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 91 mm |
| width | 22.5 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 94 mm |
| ● solid | 2x (0.25 ... 1.5 mm²) |
| Group Code | R711 |
| — upwards | 0 mm |
| ● at 24 V | 1 A |
| Confirmation | |
| Date5/6/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | LAO----- |
| — forwards | 0 mm |
| ● at 125 V | 0.2 A |
| ● at 250 V | 0.1 A |
| ● stranded | 24 ... 16 |
| Product Group | 5885 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| — backwards | 0 mm |
| — downwards | 0 mm |
| Commodity Code | 85364900 |
| Product family | Level monitoring |
| last modified: | 1/8/2021 |
| Net Weight (kg) | 0,123 Kg |
| type of voltage | |
| — at the side | 0 mm |
| ● rated value | 24 ... 240 V |
| Depth (EF000049) | 91.0 |
| Width (EF000008) | 22.5 |
| fastening method | screw and snap-on mounting |
| product function | Monitoring relay for level monitoring |
| required spacing | |
| Country of origin | Czech Republic |
| Height (EF000040) | 94.0 |
| Test Certificates | Marine / Shipping |
| mounting position | any |
| ● initial value | 0.85 |
| ● when starting | 0.5 ... 10 s |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| galvanic isolation | |
| insulation voltage | |
| product brand name | SIRIUS |
| ● during storage | -40 ... +80 °C |
| ● external reset | Yes |
| ● for live parts | |
| Packaging Dimension | 99,00 x 109,00 x 30,00 |
| Product Description | Analog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC 2-step or 1-step control Tripping delay 0.5 to 10 s 1 change-over contact spring-type connection system |
| ambient temperature | |
| degree of pollution | 3 |
| display version LED | Yes |
| product designation | Level monitoring relay with analog setting |
| protection class IP | IP20 |
| — at 24 V maximum | 2 VA |
| — at 240 V maximum | 4 VA |
| ● during operation | -25 ... +60 °C |
| ● during transport | -40 ... +80 °C |
| ● full-scale value | 1.1 |
| Cascadable (EF000507) | - |
| number of CO contacts | |
| ● delayed switching | 1 |
| conducted interference | |
| ● for grounded parts | |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at AWG cables solid | 2x (24 ... 16) |
| ● between the outputs | No |
| General Product Approval | EMC |
| product type designation | 3UG4 |
| relative repeat accuracy | 1 % |
| ● at 250 V at 50/60 Hz | 3 A |
| ● at 400 V at 50/60 Hz | 3 A |
| ● at 50 Hz rated value | 24 ... 240 V |
| ● at 60 Hz rated value | 24 ... 240 V |
| temperature drift per °C | 1 %/°C |
| Export Control Regulations | AL : N / ECCN : N |
| ● at AWG cables stranded | 2x (24 ... 16) |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| relative metering precision | 20 % |
| Package size unit of measure | MM |
| control supply voltage at AC | |
| control supply voltage at DC | |
| physical measuring principle | conductive |
| ● between input and output | Yes |
| Substance Prohibitance (Date) | 05/01/2012 |
| type of electrical connection | spring-loaded terminals |
| ● adjustable responsiveness | Yes |
| adjustable response delay time | |
| ● with side-by-side mounting | |
| ● inlet monitoring adjustable | Yes |
| ● outlet monitoring adjustable | Yes |
| With detachable clamps (EF003340) | true |
| ● of the control supply voltage | AC/DC |
| Type Test Certificates/Test Report | Special Test Certificate |
| connectable conductor cross-section | |
| operational current at 17 V minimum | 5 mA |
| surge voltage resistance rated value | 4 kV |
| ● Apparent power consumption at DC | |
| ● apparent power consumption at AC | |
| Article Number (Market Facing Number) | 3UG4501-2AW30 |
| Voltage type for actuating (EF008242) | AC/DC |
| ampacity of the output relay at AC-15 | |
| ampacity of the output relay at DC-13 | |
| Type of electric connection (EF003961) | Spring clamp connection |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| number of NC contacts delayed switching | 0 |
| number of NO contacts delayed switching | 0 |
| reference code according to IEC 81346-2 | K |
| ● with lower or upper limit violation | 0.5 ... 10 s |
| Max. permitted off-delay time (EF008191) | 10 |
| Min. adjustable off-delay time (EF008192) | 0.5 |
| Physical measurement principle (EF008238) | Other |
| Number of inputs for electrodes (EF003427) | 1 |
| tightening torque with screw-type terminals | 0.8 ... 1.2 N·m |
| ● due to burst according to IEC 61000-4-4 | 2 kV |
| Max. permitted operate delay time (EF008194) | 10 |
| shock resistance according to IEC 60068-2-27 | sinusoidal half-wave 15g / 11 ms |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 2 x (0.25 ... 1.5 mm²) |
| Min. adjustable operate delay time (EF008195) | 0.5 |
| operating frequency with 3RT2 contactor maximum | 5 000 1/h |
| vibration resistance according to IEC 60068-2-6 | 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g |
| ● finely stranded without core end processing | 2x (0.25 ... 1.5 mm²) |
| Rated control supply voltage Us at DC (EF003980) | ['24', '240'] |
| Response value sensitivity adjustable (EF003429) | true |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| mechanical service life (switching cycles) typical | 10 000 000 |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| Number of contacts as change-over contact (EF008257) | 1 |
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H |
| buffering time in the event of power failure minimum | 200 ms |
| manufacturer's article number of the optional sensor | 2-pole and 3-pole sensors 3UG3207 |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['24.0', '240.0'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['24.0', '240.0'] |
| Number of contacts as normally open contact (EF008256) | 0 |
| AWG number as coded connectable conductor cross section | |
| installation altitude at height above sea level maximum | 2 000 m |
| Number of contacts as normally closed contact (EF008255) | 0 |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| continuous current of the DIAZED fuse link of the output relay | 4 A |
| operating range factor control supply voltage rated value at DC | |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| electrical endurance (switching cycles) at AC-15 at 230 V typical | 100 000 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| product component removable terminal for auxiliary and control circuit | Yes |
| REACH Art. 33 Duty to inform according to the current list of candidates | Tris(2-chloroethyl) ... CAS-No. 115-96-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Tris(2-chloroethyl) phosphate (TCEP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dicyclohexyl phthala... CAS-No. 84-61-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dicyclohexyl phthalate (DCHP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| operating range factor control supply voltage rated value at AC at 50 Hz | |
| operating range factor control supply voltage rated value at AC at 60 Hz | |
| ● for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value | 300 V |
| General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherRailwayType Test Certificates/Test ReportSpecial Test CertificateConfirmationVibration and Shock | General Product Approval |
Technical specifications and performance data
Installation and operation guide