Service time: Monday to Friday 9:00-18:00
3UG4501-2AA30 - 3UG4501-2AA30 SIEMENS Analog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm..
In Stock Hot Product

3UG4501-2AA30

3UG4501-2AA30 SIEMENS Analog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm..

$0.00USD
4903 in stock
Key Specifications
:
EAN:4011209665316
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209665316
UPCNot available
ETIM5
IDEA4
depth91 mm
width22.5 mm
UNSPSC15
eClass6
height94 mm
● solid2x (0.25 ... 1.5 mm²)
Group CodeR711
— upwards0 mm
● at 24 V1 A
Date5/5/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
— forwards0 mm
● at 125 V0.2 A
● at 250 V0.1 A
● stranded24 ... 16
Product Group5885
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards0 mm
Commodity Code85364190
Product familyLevel monitoring
last modified:1/18/2021
Net Weight (kg)0,123 Kg
type of voltage
— at the side0 mm
● rated value24 ... 24 V
Depth (EF000049)91.0
Width (EF000008)22.5
fastening methodscrew and snap-on mounting
product functionMonitoring relay for level monitoring
required spacing
Country of originCzech Republic
Height (EF000040)94.0
Test CertificatesMarine / Shipping
mounting positionany
● initial value0.85
● when starting0.5 ... 10 s
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
galvanic isolation
insulation voltage
product brand nameSIRIUS
● during storage-40 ... +80 °C
● external resetYes
● for live parts
Packaging Dimension99,00 x 108,00 x 30,00
Product DescriptionAnalog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm 0vershoot and undershoot Supply voltage 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit 2-step or 1-step control Tripping delay 0.5 to 10 s 1 change-over contact spring-type connection system
ambient temperature
degree of pollution3
display version LEDYes
product designationLevel monitoring relay with analog setting
protection class IPIP20
— at 24 V maximum2 VA
● during operation-25 ... +60 °C
● during transport-40 ... +80 °C
● full-scale value1.1
Cascadable (EF000507)-
number of CO contacts
● delayed switching1
conducted interference
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
● at AWG cables solid2x (24 ... 16)
● between the outputsNo
General Product ApprovalEMC
Special Test CertificateType Test Certificates/Test Report
product type designation3UG4
relative repeat accuracy1 %
● at 250 V at 50/60 Hz3 A
● at 400 V at 50/60 Hz3 A
● at 50 Hz rated value24 ... 24 V
● at 60 Hz rated value24 ... 24 V
temperature drift per °C1 %/°C
Export Control RegulationsAL : N / ECCN : N
● at AWG cables stranded2x (24 ... 16)
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
relative metering precision20 %
Package size unit of measureMM
control supply voltage at AC
control supply voltage at DC
physical measuring principleconductive
● between input and outputYes
Substance Prohibitance (Date)05/01/2012
type of electrical connectionspring-loaded terminals
● adjustable responsivenessYes
adjustable response delay time
● with side-by-side mounting
● inlet monitoring adjustableYes
● outlet monitoring adjustableYes
With detachable clamps (EF003340)true
● of the control supply voltageAC/DC
connectable conductor cross-section
operational current at 17 V minimum5 mA
surge voltage resistance rated value4 kV
● Apparent power consumption at DC
● apparent power consumption at AC
Article Number (Market Facing Number)3UG4501-2AA30
Voltage type for actuating (EF008242)AC/DC
ampacity of the output relay at AC-15
ampacity of the output relay at DC-13
Type of electric connection (EF003961)Spring clamp connection
WEEE (2012/19/EU) Take-Back ObligationYes
number of NC contacts delayed switching0
number of NO contacts delayed switching0
reference code according to IEC 81346-2K
● with lower or upper limit violation0.5 ... 10 s
Max. permitted off-delay time (EF008191)10
Min. adjustable off-delay time (EF008192)0.5
Physical measurement principle (EF008238)Other
Number of inputs for electrodes (EF003427)1
tightening torque with screw-type terminals0.8 ... 1.2 N·m
● due to burst according to IEC 61000-4-42 kV
Max. permitted operate delay time (EF008194)10
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
type of connectable conductor cross-sections
● finely stranded with core end processing2 x (0.25 ... 1.5 mm²)
Min. adjustable operate delay time (EF008195)0.5
operating frequency with 3RT2 contactor maximum5 000 1/h
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
● finely stranded without core end processing2x (0.25 ... 1.5 mm²)
Rated control supply voltage Us at DC (EF003980)['24', '24']
Response value sensitivity adjustable (EF003429)true
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
mechanical service life (switching cycles) typical10 000 000
field-based interference according to IEC 61000-4-310 V/m
Number of contacts as change-over contact (EF008257)1
Region Specific PriceGroup / Headquarter Price Group41H / 41H
buffering time in the event of power failure minimum200 ms
manufacturer's article number of the optional sensor2-pole and 3-pole sensors 3UG3207
Rated control supply voltage Us at AC 50HZ (EF003978)['24.0', '24.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['24.0', '24.0']
Number of contacts as normally open contact (EF008256)0
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
Number of contacts as normally closed contact (EF008255)0
● due to conductor-earth surge according to IEC 61000-4-52 kV
continuous current of the DIAZED fuse link of the output relay4 A
operating range factor control supply voltage rated value at DC
● due to conductor-conductor surge according to IEC 61000-4-51 kV
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value at AC at 50 Hz
operating range factor control supply voltage rated value at AC at 60 Hz
● for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherRailwaySpecial Test CertificateType Test Certificates/Test ReportConfirmationVibration and ShockGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top