Service time: Monday to Friday 9:00-18:00
3UF7310-1AU00-0 - 3UF7310-1AU00-0 SIEMENS Digital module, 4 inputs and 2 relay outputs, input voltage 110-240 V AC/DC relay ou..
In Stock Hot Product

3UF7310-1AU00-0

3UF7310-1AU00-0 SIEMENS Digital module, 4 inputs and 2 relay outputs, input voltage 110-240 V AC/DC relay ou..

$0.00USD
3402 in stock
Key Specifications
:
EAN:4011209606234
UPC:754554901916
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209606234
UPC754554901916
ETIM5
IDEA4
depth124 mm
width22.5 mm
UNSPSC14
eClass6
height92 mm
● top40 mm
● left0 mm
● right0 mm
● solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Group CodeR711
● bottom40 mm
● at 24 V6 A
● at 60 V0.55 A
Date5/5/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorNone
● at 120 V6 A
● at 125 V0.25 A
● at 230 V3 A
Product Group5836
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
● 1 maximum2 000 m
● 2 maximum3 000 m; max. +50 °C (no protective separation)
● 3 maximum4 000 m; max. +40 °C (no protective separation)
● at 50 °C6 A
● at 60 °C5 A
Commodity Code85371098
Product familySIMOCODE pro 3UF7 motor management and control devices
last modified:4/7/2022
Net Weight (kg)0,151 Kg
● rated value110 ... 240 V
Model (EF000010)Digital module
fastening methodscrew and snap-on mounting
number of inputs4
product function
required spacing
● relay outputYes
Country of originGermany
mounting positionany
number of outputs2
product component
● digital inputYes
● initial value0.85
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
switching behaviorbistable
● during storage-40 ... +80 °C
Packaging Dimension28,00 x 108,50 x 147,00
Product DescriptionDigital module, 4 inputs and 2 relay outputs, input voltage 110-240 V AC/DC relay outputs bistable, max. 2 digital modules, for SIMOCODE pro V basic unit
ambient temperature
product designationdigital modules
protection class IPIP20
● during operation-25 ... +60 °C
● during transport-40 ... +80 °C
● full-scale value1.1
consumed active power0.7 W
digital input version
conducted interference
environmental category
Product Lifecycle (PLM)PM300:Active Product
number of analog inputs0
● at AWG cables solid1x (20 ... 14), 2x (20 ... 16)
General Product ApprovalEMC
number of analog outputs0
number of digital inputs4
● at 50 Hz rated value110 ... 240 V
● at 60 Hz rated value110 ... 240 V
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
● at AWG cables stranded1x (20 ... 12), 2x (20 ... 14)
● parameterizable inputsYes
Standard lead time ex-works1 Day/Days
Surcharge for Raw MaterialsNone
● parameterizable outputsYes
Package size unit of measureMM
control supply voltage at AC
control supply voltage at DC
● type 1 acc. to IEC 61131No
● type 2 acc. to IEC 61131No
Substance Prohibitance (Date)05/01/2012
Switching function (EF000189)Bistable
number of semiconductor outputs0
Number of binary inputs (EF003817)4
control supply voltage frequency 150 ... 60 Hz
relative humidity during operation5 ... 95 %
● input for thermistor connectionNo
Degree of protection (IP) (EF005474)IP20
Number of analogue inputs (EF001994)0
surge voltage resistance rated value4 000 V
● input for ground fault detectionNo
Article Number (Market Facing Number)3UF7310-1AU00-0
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
Number of analogue outputs (EF001995)0
Voltage type for actuating (EF008242)AC/DC
● with a common reference potential4
Degree of protection (NEMA) (EF011959)-
WEEE (2012/19/EU) Take-Back ObligationYes
Number of electronic outputs (EF006929)0
reference code according to IEC 81346-2K
wire length for digital signals maximum200 m
● input for analog temperature sensorsNo
property of contacts of the relay outputsFloating NO contacts (NC reaction parameterizable via internal signal conditioning), connected to common ground, can be freely assigned to the control functions (e.g. line, star (wye), delta contactor or signaling of the operating state)
touch protection against electrical shockfinger-safe
● during storage according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Input for earth fault detection (EF007115)false
Input for thermistor connection (EF007116)false
Number of outputs, with contact (EF006936)2
tightening torque with screw-type terminals0.8 ... 1.2 N·m
● due to burst according to IEC 61000-4-41 kV
● during operation according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
● during transport according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
shock resistance according to IEC 60068-2-2715g / 11 ms
type of connectable conductor cross-sections
● finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
design of short-circuit protection per outputFuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)
type of voltage of the control supply voltageAC/DC
electrical endurance (switching cycles) typical100 000
installation altitude at height above sea level
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
Input for analogue temperature sensor (EF007114)false
Rated control supply voltage Us at DC (EF003980)['110', '240']
input voltage at digital input at DC rated value110 V
EMC emitted interference according to IEC 60947-1class A
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
mechanical service life (switching cycles) typical10 000 000
field-based interference according to IEC 61000-4-310 V/m
Region Specific PriceGroup / Headquarter Price Group42J / 42J
contact rating of auxiliary contacts according to ULB300 / R300
Rated control supply voltage Us at AC 50HZ (EF003978)['110.0', '240.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['110.0', '240.0']
tightening torque [lbf·in] with screw-type terminals7 ... 10.3 lbf·in
number of outputs as contact-affected switching element2
conducted HF interference emissions according to CISPR11corresponds to degree of severity A
field-bound HF interference emission according to CISPR11corresponds to degree of severity A
continuous current of the NO contacts of the relay outputs
● due to conductor-earth surge according to IEC 61000-4-52 kV
(electrically) protective separation according to IEC 60947-1All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
● due to high-frequency radiation according to IEC 61000-4-610 V
insulation voltage with degree of pollution 3 at AC rated value300 V
operating range factor control supply voltage rated value at DC
● due to conductor-conductor surge according to IEC 61000-4-51 kV
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value at AC at 50 Hz
operating range factor control supply voltage rated value at AC at 60 Hz
switching capacity current of the NO contacts of the relay outputs at AC-15
switching capacity current of the NO contacts of the relay outputs at DC-13
Type of electrical connection for auxiliary- and control current circuit (EF006979)Screw connection
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesMarine / ShippingotherType Test Certificates/Test ReportConfirmationotherGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top