| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4011209606203 |
| UPC | 754554901893 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 124 mm |
| width | 22.5 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 92 mm |
| ● top | 40 mm |
| ● left | 0 mm |
| ● right | 0 mm |
| ● solid | 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) |
| Group Code | R711 |
| ● bottom | 40 mm |
| ● at 24 V | 6 A |
| ● at 60 V | 0.55 A |
| Date5/4/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | None |
| ● at 120 V | 6 A |
| ● at 125 V | 0.25 A |
| ● at 230 V | 3 A |
| Product Group | 5836 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| ● 1 maximum | 2 000 m |
| ● 2 maximum | 3 000 m; max. +50 °C (no protective separation) |
| ● 3 maximum | 4 000 m; max. +40 °C (no protective separation) |
| ● at 50 °C | 6 A |
| ● at 60 °C | 5 A |
| Commodity Code | 85371098 |
| Product family | SIMOCODE pro 3UF7 motor management and control devices |
| last modified: | 4/7/2022 |
| Net Weight (kg) | 0,156 Kg |
| ● rated value | 110 ... 240 V |
| Model (EF000010) | Digital module |
| fastening method | screw and snap-on mounting |
| number of inputs | 4 |
| product function | |
| required spacing | |
| ● relay output | Yes |
| Country of origin | Germany |
| Test Certificates | Marine / Shipping |
| mounting position | any |
| number of outputs | 2 |
| product component | |
| ● digital input | Yes |
| ● initial value | 0.85 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| switching behavior | monostable |
| ● during storage | -40 ... +80 °C |
| Packaging Dimension | 28,00 x 108,50 x 147,00 |
| Product Description | Digital module, 4 inputs and 2 relay outputs, input voltage 110-240 V AC/DC relay outputs monostable, max. 2 digital modules, for SIMOCODE pro V basic unit |
| ambient temperature | |
| product designation | digital modules |
| protection class IP | IP20 |
| ● during operation | -25 ... +60 °C |
| ● during transport | -40 ... +80 °C |
| ● full-scale value | 1.1 |
| consumed active power | 0.7 W |
| digital input version | |
| conducted interference | |
| environmental category | |
| Product Lifecycle (PLM) | PM300:Active Product |
| number of analog inputs | 0 |
| ● at AWG cables solid | 1x (20 ... 14), 2x (20 ... 16) |
| General Product Approval | For use in hazardous locations |
| number of analog outputs | 0 |
| number of digital inputs | 4 |
| ● at 50 Hz rated value | 110 ... 240 V |
| ● at 60 Hz rated value | 110 ... 240 V |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| ● at AWG cables stranded | 1x (20 ... 12), 2x (20 ... 14) |
| ● parameterizable inputs | Yes |
| Standard lead time ex-works | 1 Day/Days |
| Surcharge for Raw Materials | None |
| ● parameterizable outputs | Yes |
| Package size unit of measure | MM |
| control supply voltage at AC | |
| control supply voltage at DC | |
| ● type 1 acc. to IEC 61131 | No |
| ● type 2 acc. to IEC 61131 | No |
| Substance Prohibitance (Date) | 05/01/2012 |
| Switching function (EF000189) | Mono stable |
| number of semiconductor outputs | 0 |
| Number of binary inputs (EF003817) | 4 |
| Type Test Certificates/Test Report | |
| control supply voltage frequency 1 | 50 ... 60 Hz |
| relative humidity during operation | 5 ... 95 % |
| ● input for thermistor connection | No |
| Degree of protection (IP) (EF005474) | IP20 |
| Number of analogue inputs (EF001994) | 0 |
| surge voltage resistance rated value | 4 000 V |
| ● input for ground fault detection | No |
| Article Number (Market Facing Number) | 3UF7300-1AU00-0 |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3 |
| Number of analogue outputs (EF001995) | 0 |
| Voltage type for actuating (EF008242) | AC/DC |
| ● with a common reference potential | 4 |
| Degree of protection (NEMA) (EF011959) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Number of electronic outputs (EF006929) | 0 |
| reference code according to IEC 81346-2 | K |
| wire length for digital signals maximum | 200 m |
| ● input for analog temperature sensors | No |
| property of contacts of the relay outputs | Floating NO contacts (NC reaction parameterizable via internal signal conditioning), connected to common ground, can be freely assigned to the control functions (e.g. line, star (wye), delta contactor or signaling of the operating state) |
| touch protection against electrical shock | finger-safe |
| ● during storage according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| Input for earth fault detection (EF007115) | false |
| Input for thermistor connection (EF007116) | false |
| Number of outputs, with contact (EF006936) | 2 |
| tightening torque with screw-type terminals | 0.8 ... 1.2 N·m |
| ● due to burst according to IEC 61000-4-4 | 1 kV |
| ● during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ● during transport according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| shock resistance according to IEC 60068-2-27 | 15g / 11 ms |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| design of short-circuit protection per output | Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A) |
| type of voltage of the control supply voltage | AC/DC |
| electrical endurance (switching cycles) typical | 100 000 |
| installation altitude at height above sea level | |
| vibration resistance according to IEC 60068-2-6 | 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g |
| Input for analogue temperature sensor (EF007114) | false |
| Rated control supply voltage Us at DC (EF003980) | ['110', '240'] |
| input voltage at digital input at DC rated value | 110 V |
| EMC emitted interference according to IEC 60947-1 | class A |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| mechanical service life (switching cycles) typical | 10 000 000 |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| Region Specific PriceGroup / Headquarter Price Group | 42J / 42J |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110.0', '240.0'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['110.0', '240.0'] |
| tightening torque [lbf·in] with screw-type terminals | 7 ... 10.3 lbf·in |
| number of outputs as contact-affected switching element | 2 |
| conducted HF interference emissions according to CISPR11 | corresponds to degree of severity A |
| field-bound HF interference emission according to CISPR11 | corresponds to degree of severity A |
| continuous current of the NO contacts of the relay outputs | |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| (electrically) protective separation according to IEC 60947-1 | All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information) |
| ● due to high-frequency radiation according to IEC 61000-4-6 | 10 V |
| insulation voltage with degree of pollution 3 at AC rated value | 300 V |
| operating range factor control supply voltage rated value at DC | |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| certificate of suitability according to ATEX directive 2014/34/EU | BVS 06 ATEX F001 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| product component removable terminal for auxiliary and control circuit | Yes |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| operating range factor control supply voltage rated value at AC at 50 Hz | |
| operating range factor control supply voltage rated value at AC at 60 Hz | |
| explosion device group and category according to ATEX directive 2014/34/EU | II (2) G, II (2 ) D, I (M2) |
| switching capacity current of the NO contacts of the relay outputs at AC-15 | |
| switching capacity current of the NO contacts of the relay outputs at DC-13 | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Screw connection |
| General Product ApprovalFor use in hazardous locationsDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherType Test Certificates/Test ReportConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide