Service time: Monday to Friday 9:00-18:00
3UF7122-1AA01-0 - 3UF7122-1AA01-0 SIEMENS Current/voltage measuring module for dry-running protection of centrifugal pumps in ..
In Stock Hot Product

3UF7122-1AA01-0

3UF7122-1AA01-0 SIEMENS Current/voltage measuring module for dry-running protection of centrifugal pumps in ..

$0.00USD
3751 in stock
Key Specifications
:
EAN:4047621058214
UPC:804766765513
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4047621058214
UPC804766765513
ETIM5
IDEA4
depth91 mm
width55 mm
UNSPSC15
eClass6
height94 mm
● top30 mm
● left0 mm
● IECExYes; IECEx PTB 18.0004X
● at AC
● right0 mm
● solid1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)
Group CodeR711
● bottom30 mm
Confirmation
Metal FactorL-O-----
Date5/14/2022Subject to change without notice© Copyright Siemens 2022
Product Group5836
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
● 1 maximum2 000 m
● 2 maximum3 000 m; max. +50 °C (no protective separation)
● 3 maximum4 000 m; max. +40 °C (no protective separation)
Commodity Code85364900
Product familySIMOCODE pro 3UF7 motor management and control devices
last modified:4/7/2022
Net Weight (kg)0,380 Kg
type of voltageAC
fastening methodscrew and snap-on mounting
product function
required spacing
Country of originGermany
Test CertificatesMarine / Shipping
mounting positionany
operating voltage
product component
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-40 ... +80 °C
Packaging Dimension121,00 x 65,00 x 119,00
Product DescriptionCurrent/voltage measuring module for dry-running protection of centrifugal pumps in hazardous areas; set current 10 ... 115 A, voltage measurement up to 690 V, width 55 mm, straight-through transformer
ambient temperature
measuring precision
product designationCurrent/voltage measuring module
protection class IPIP20
vibration resistance1-6 Hz / 15 mm; 6-500 Hz / 2 g; with basic unit snapped on: 1g
● during operation-25 ... +60 °C
● during transport-40 ... +80 °C
consumed active power0.5 W
● current detectionYes
● power measurementYes
● voltage detectionYes
conducted interference
environmental category
inrush current maximum1 150 A; 10 x Io
Product Lifecycle (PLM)PM300:Active Product
● at AWG cables solid1x (24 ... 14), 2x (24 ... 18)
● current measurementYes
● overload protectionYes
● voltage measurementYes
General Product ApprovalEMC
Special Test CertificateSpecial Test Certificate
— at 50 Hz rated value110 ... 690 V
— at 60 Hz rated value110 ... 690 V
diameter of inlet opening14 mm
temperature drift per °C0.01 %/°C; Reference temperature: 25°C
● frequency measurementYes
Export Control RegulationsAL : N / ECCN : EAR99
certificate of suitability
● at AWG cables stranded1x (20 ... 14), 2x (20 ... 16)
Standard lead time ex-works1 Day/Days
Surcharge for Raw MaterialsNone
measured variable frequency45 ... 65 Hz
● at energy measurement 1+/- 5%, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● at energy measurement 2+/- 10%, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● ground-fault monitoringYes
● power factor monitoringYes
Package size unit of measureMM
● active power measurementYes
● at cos phi-measurement 1+/- 1.5 %, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
● at cos phi-measurement 2+/- 5%, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● of frequency measurement+/- 1.5 %, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
Substance Prohibitance (Date)05/28/2009
● for current measurement 1+/- 1.5 %, in range 7.5 A ... 230 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
● for current measurement 2+/- 3%, in range 230 A ... 920 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
● for voltage measurement 1+/- 1.5 %, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
For use in hazardous locationsDeclaration of Conformity
operating frequency rated value50 ... 60 Hz
● at active power measurement 1+/- 5%, 15 A ... 400 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● at active power measurement 2+/- 10%, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
relative humidity during operation10 ... 95 %
accuracy of ground-fault monitoringIn the range 30 % .. 120 %/Is: +/- 10 % (Class CI-A), in range 15 % .. 30 % Ie: +/- 25 % (Class CI-B), both values acc. to IEC 60947-1 Annex T
● at apparent power measurement 1+/- 3%, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● at apparent power measurement 2+/- 5 %, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
● input for thermistor connectionNo
surge voltage resistance rated value6 000 V
Article Number (Market Facing Number)3UF7122-1AA01-0
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
WEEE (2012/19/EU) Take-Back ObligationYes
number of poles for main current circuit3
product function short circuit protectionNo
● during storage according to IEC 607211K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
● according to ATEX directive 2014/34/EUBVS 06 ATEX F001, PTB 18 ATEX 5003 X
measuring procedure for current measurementTRMS
measuring procedure for voltage measurementTRMS
● due to burst according to IEC 61000-4-42 kV
● during operation according to IEC 607213K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2
shock resistance according to IEC 60068-2-2715g / 11 ms; with basic unit snapped on
● finely stranded with core end processing1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)
installation altitude at height above sea level
● with degree of pollution 3 at AC rated value690 V
EMC emitted interference according to IEC 60947-1class A
diameter of inlet opening for current measurement14 mm
field-based interference according to IEC 61000-4-310 V/m
Region Specific PriceGroup / Headquarter Price Group42J / 42J
number of outputs as contact-affected switching element0
tightening torque at the measurement inputs for voltage0.5 ... 0.6 N·m
● due to conductor-earth surge according to IEC 61000-4-52 kV
(electrically) protective separation according to IEC 60947-1All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
● due to conductor-conductor surge according to IEC 61000-4-51 kV
tightening torque [lbf·in] at the measurement inputs for voltage4.4 ... 5.3 lbf·in
● for wires of main circuit according to IEC 60947-1 rated value6 kV
type of electrical connection at the measurement inputs for voltagescrew-type terminals
current measuring range extension with external current transformersNo
Compliance with the substance restrictions according to RoHS directiveSince: 28.05.2009
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-oneBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
explosion device group and category according to ATEX directive 2014/34/EUII (2) G, II (2 ) D, I (M2) / I (1G/M2), II (1/2) G, II (1G/2D)
measurable supply voltage between the line conductors at AC maximum rated value690 V
line conductors and neutral conductors internal resistance for voltage measurementRC-based voltage divider
type of connectable conductor cross-sections at the measurement inputs for voltage
adjustable current response value current of the current-dependent overload release10 ... 115 A
● active power monitoring for pump dry-run according to Ignition protection type Ex bYes
General Product ApprovalEMCConfirmationFor use in hazardous locationsDeclaration of ConformityTest CertificatesType Test Certificates/Test ReportTest CertificatesMarine / ShippingSpecial Test CertificateSpecial Test CertificateotherConfirmationGeneral Product Approval

Product Description

Intensity/voltage measurement module for dry running protection of centrifugal pumps in zone Ex; adjustment current 10...115 A, voltage measurement up to 690 V, 55 mm wide, transformer with primary th
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top