| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4047621025728 |
| UPC | 804766420702 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 149 mm |
| width | 145 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 147 mm |
| ● top | 30 mm |
| ● left | 0 mm |
| ● at AC | |
| ● right | 0 mm |
| ● solid | 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) |
| Group Code | R711 |
| ● bottom | 30 mm |
| Metal Factor | L-P----- |
| Date5/14/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 5836 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| ● 1 maximum | 2 000 m |
| ● 2 maximum | 3 000 m; max. +50 °C (no protective separation) |
| ● 3 maximum | 4 000 m; max. +40 °C (no protective separation) |
| Commodity Code | 85364900 |
| Product family | SIMOCODE pro 3UF7 motor management and control devices |
| last modified: | 4/7/2022 |
| Net Weight (kg) | 1,835 Kg |
| type of voltage | AC |
| fastening method | direct mounting / stand-alone installation |
| product function | |
| required spacing | |
| Country of origin | Germany |
| Marine / Shipping | other |
| mounting position | any |
| operating voltage | |
| product component | |
| ● at AWG cables | 1/0 kcmil ... 500 kcmil |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| insulation voltage | |
| product brand name | SIRIUS |
| ● during storage | -40 ... +80 °C |
| Packaging Dimension | 151,00 x 178,00 x 154,00 |
| Product Description | Current/voltage measuring module V2; Set current 63...630 A, Voltage measurement up to 690 V, Overall width 145 mm, Busbar connection basic unit required pro V PB, pro V MR, pro V PN or pro V EIP |
| ambient temperature | |
| measuring precision | |
| product designation | Current/voltage measuring module |
| protection class IP | IP00 |
| vibration resistance | 1-6 Hz / 15 mm; 6-500 Hz / 2 g; with basic unit snapped on: 1g |
| ● during operation | -25 ... +60 °C |
| ● during transport | -40 ... +80 °C |
| consumed active power | 0.5 W |
| ● current detection | Yes |
| ● power measurement | Yes |
| ● voltage detection | Yes |
| PROFINET-Certification | |
| conducted interference | |
| environmental category | |
| inrush current maximum | 6 300 A; 10 x Io |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
| ● current measurement | Yes |
| ● overload protection | Yes |
| ● voltage measurement | Yes |
| General Product Approval | EMC |
| — at 50 Hz rated value | 110 ... 690 V |
| — at 60 Hz rated value | 110 ... 690 V |
| temperature drift per °C | 0.01 %/°C; Reference temperature: 25°C |
| ● frequency measurement | Yes |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| certificate of suitability | |
| ● at AWG cables stranded | 1x (20 ... 14), 2x (20 ... 16) |
| Standard lead time ex-works | 1 Day/Days |
| Surcharge for Raw Materials | None |
| measured variable frequency | 45 ... 65 Hz |
| ● at energy measurement 1 | +/- 5 %, 47 ... 1260 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C |
| ● at energy measurement 2 | +/- 10%, 1260 A ... 5040 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C |
| ● ground-fault monitoring | Yes |
| ● power factor monitoring | Yes |
| Package size unit of measure | MM |
| Type of interface (EF006977) | - |
| ● active power measurement | Yes |
| ● at cos phi-measurement 1 | +/- 1.5 %, 47 A ... 1260 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C |
| ● at cos phi-measurement 2 | +/- 5%, 1260 A ... 5040 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C |
| ● of frequency measurement | +/- 1.5 %, 47 A ... 1260 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C |
| Substance Prohibitance (Date) | 05/28/2009 |
| Switching function (EF000189) | - |
| ● for current measurement 1 | +/- 1.5 %, in range 47 A ... 1260 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C |
| ● for current measurement 2 | +/- 5%, in range 1260 A ... 5040 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C |
| ● for voltage measurement 1 | +/- 1.5 %, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C |
| For use in hazardous locations | Declaration of Conformity |
| operating frequency rated value | 50 ... 60 Hz |
| Rated voltage Ue at DC (EF007031) | - |
| ● at active power measurement 1 | +/- 5 %, 47 ... 1260 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C |
| ● at active power measurement 2 | +/- 10%, 1260 A ... 5040 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C |
| Number of binary inputs (EF003817) | - |
| relative humidity during operation | 10 ... 95 % |
| ● solid with core end processing | 50 mm² ... 240 mm² |
| Current detection module (EF007501) | true |
| Voltage detection module (EF007492) | true |
| accuracy of ground-fault monitoring | In the range 30 % .. 120 %/Is: +/- 10 % (Class CI-A), in range 15 % .. 30 % Ie: +/- 25 % (Class CI-B), both values acc. to IEC 60947-1 Annex T |
| ● at apparent power measurement 1 | +/- 3%, 47 A ... 1260 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C |
| ● at apparent power measurement 2 | +/- 5 %, 1260 A ... 5040 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C |
| ● input for thermistor connection | No |
| Degree of protection (IP) (EF005474) | IP00 |
| Number of analogue inputs (EF001994) | - |
| Rated operation frequency (EF007024) | ['50.0', '60.0'] |
| Type of connection system (EF008220) | Rail connection |
| surge voltage resistance rated value | 6 000 V |
| Article Number (Market Facing Number) | 3UF7114-1BA01-0 |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3 |
| Number of analogue outputs (EF001995) | - |
| Rated operation current Ie (EF006781) | - |
| Voltage type for actuating (EF008242) | AC |
| ● stranded with core end processing | 70 mm² ... 240 mm² |
| Degree of protection (NEMA) (EF011959) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Number of electronic outputs (EF006929) | - |
| Rated voltage Ue at AC 50 Hz (EF007029) | ['110', '690'] |
| Rated voltage Ue at AC 60 Hz (EF007030) | ['110', '690'] |
| reference code according to IEC 81346-2 | F |
| number of poles for main current circuit | 3 |
| product function short circuit protection | No |
| ● during storage according to IEC 60721 | 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4 |
| Input for earth fault detection (EF007115) | - |
| Input for thermistor connection (EF007116) | false |
| Number of outputs, with contact (EF006936) | 0 |
| ● according to ATEX directive 2014/34/EU | BVS 06 ATEX F001 |
| measuring procedure for current measurement | TRMS |
| measuring procedure for voltage measurement | TRMS |
| ● due to burst according to IEC 61000-4-4 | 2 kV |
| ● during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ● during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 |
| shock resistance according to IEC 60068-2-27 | 15g / 11 ms; with basic unit snapped on |
| ● finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| installation altitude at height above sea level | |
| Input for analogue temperature sensor (EF007114) | - |
| Rated control supply voltage Us at DC (EF003980) | - |
| ● with degree of pollution 3 at AC rated value | 690 V |
| EMC emitted interference according to IEC 60947-1 | class A |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| Region Specific PriceGroup / Headquarter Price Group | 42J / 42J |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| number of outputs as contact-affected switching element | 0 |
| tightening torque at the measurement inputs for voltage | 0.8 ... 1.2 N·m |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| (electrically) protective separation according to IEC 60947-1 | All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information) |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| tightening torque [lbf·in] at the measurement inputs for voltage | 7 ... 10.3 lbf·in |
| ● for wires of main circuit according to IEC 60947-1 rated value | 6 kV |
| type of electrical connection at the measurement inputs for voltage | screw-type terminals |
| current measuring range extension with external current transformers | No |
| Compliance with the substance restrictions according to RoHS directive | Since: 28.05.2009 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| explosion device group and category according to ATEX directive 2014/34/EU | II (2) G, II (2 ) D, I (M2) |
| measurable supply voltage between the line conductors at AC maximum rated value | 690 V |
| design of the thread of the connection screw at the measurement inputs for current | M10 x 30 |
| line conductors and neutral conductors internal resistance for voltage measurement | 1 MΩ; RC-based voltage divider |
| type of connectable conductor cross-sections at the measurement inputs for current | |
| type of connectable conductor cross-sections at the measurement inputs for voltage | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Screw connection |
| adjustable current response value current of the current-dependent overload release | 63 ... 630 A |
| General Product ApprovalEMCConfirmationFor use in hazardous locationsDeclaration of ConformityTest CertificatesSpecial Test CertificateType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingotherConfirmationotherPROFINET-Certification | General Product Approval |
Technical specifications and performance data
Installation and operation guide