Key Specifications
:
EAN:4047621025759
UPC:804766420733
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4047621025759
UPC804766420733
ETIM5
IDEA4
depth91 mm
width55 mm
UNSPSC15
eClass6
height94 mm
● top30 mm
● left0 mm
● at AC
● right0 mm
● solid1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)
Group CodeR711
● bottom30 mm
ConfirmationPROFINET-Certification
Date5/8/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorL-O-----
Product Group5836
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
● 1 maximum2 000 m
● 2 maximum3 000 m; max. +50 °C (no protective separation)
● 3 maximum4 000 m; max. +40 °C (no protective separation)
Commodity Code85364900
Product familySIMOCODE pro 3UF7 motor management and control devices
last modified:4/7/2022
Net Weight (kg)0,352 Kg
type of voltageAC
fastening methodscrew and snap-on mounting
product function
required spacing
Country of originGermany
Test CertificatesMarine / Shipping
mounting positionany
operating voltage
product component
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-40 ... +80 °C
Packaging Dimension62,00 x 124,00 x 119,00
Product DescriptionCurrent/voltage measuring module V2; Set current 10...115 A, Voltage measurement up to 690 V, Overall width 55 mm, Straight-through transformer, basic unit required pro V PB, pro V MR, pro V PN or pro V EIP
ambient temperature
measuring precision
product designationCurrent/voltage measuring module
protection class IPIP20
vibration resistance1-6 Hz / 15 mm; 6-500 Hz / 2 g; with basic unit snapped on: 1g
● during operation-25 ... +60 °C
● during transport-40 ... +80 °C
consumed active power0.5 W
● current detectionYes
● power measurementYes
● voltage detectionYes
conducted interference
environmental category
inrush current maximum1 150 A; 10 x Io
Product Lifecycle (PLM)PM300:Active Product
● at AWG cables solid1x (24 ... 14), 2x (24 ... 18)
● current measurementYes
● overload protectionYes
● voltage measurementYes
General Product ApprovalEMC
— at 50 Hz rated value110 ... 690 V
— at 60 Hz rated value110 ... 690 V
diameter of inlet opening14 mm
temperature drift per °C0.01 %/°C; Reference temperature: 25°C
● frequency measurementYes
Export Control RegulationsAL : N / ECCN : EAR99
certificate of suitability
● at AWG cables stranded1x (20 ... 14), 2x (20 ... 16)
Standard lead time ex-works60 Day/Days
Surcharge for Raw MaterialsNone
measured variable frequency45 ... 65 Hz
● at energy measurement 1+/- 5%, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● at energy measurement 2+/- 10%, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● ground-fault monitoringYes
● power factor monitoringYes
Package size unit of measureMM
Type of interface (EF006977)-
● active power measurementYes
● at cos phi-measurement 1+/- 1.5 %, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
● at cos phi-measurement 2+/- 5%, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● of frequency measurement+/- 1.5 %, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
Substance Prohibitance (Date)05/28/2009
Switching function (EF000189)-
● for current measurement 1+/- 1.5 %, in range 7.5 A ... 230 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
● for current measurement 2+/- 3%, in range 230 A ... 920 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
● for voltage measurement 1+/- 1.5 %, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz, 25 °C
For use in hazardous locationsDeclaration of Conformity
operating frequency rated value50 ... 60 Hz
Rated voltage Ue at DC (EF007031)-
● at active power measurement 1+/- 5%, 15 A ... 400 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● at active power measurement 2+/- 10%, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
Number of binary inputs (EF003817)-
Type Test Certificates/Test ReportSpecial Test Certificate
relative humidity during operation10 ... 95 %
Current detection module (EF007501)true
Voltage detection module (EF007492)true
accuracy of ground-fault monitoringIn the range 30 % .. 120 %/Is: +/- 10 % (Class CI-A), in range 15 % .. 30 % Ie: +/- 25 % (Class CI-B), both values acc. to IEC 60947-1 Annex T
● at apparent power measurement 1+/- 3%, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-phi (0.5...1), 50/60 Hz, 25 °C
● at apparent power measurement 2+/- 5 %, 230 A ... 920 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos phi (0.5...1), 50/60 Hz, 25 °C
● input for thermistor connectionNo
Degree of protection (IP) (EF005474)IP20
Number of analogue inputs (EF001994)-
Rated operation frequency (EF007024)['50.0', '60.0']
Type of connection system (EF008220)Through-feed technique
surge voltage resistance rated value6 000 V
Article Number (Market Facing Number)3UF7112-1AA01-0
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
Number of analogue outputs (EF001995)-
Rated operation current Ie (EF006781)-
Voltage type for actuating (EF008242)AC
Degree of protection (NEMA) (EF011959)-
WEEE (2012/19/EU) Take-Back ObligationYes
Number of electronic outputs (EF006929)-
Rated voltage Ue at AC 50 Hz (EF007029)['110', '690']
Rated voltage Ue at AC 60 Hz (EF007030)['110', '690']
reference code according to IEC 81346-2F
number of poles for main current circuit3
product function short circuit protectionNo
● during storage according to IEC 607211K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
Input for earth fault detection (EF007115)-
Input for thermistor connection (EF007116)false
Number of outputs, with contact (EF006936)0
● according to ATEX directive 2014/34/EUBVS 06 ATEX F001
measuring procedure for current measurementTRMS
measuring procedure for voltage measurementTRMS
● due to burst according to IEC 61000-4-42 kV
● during operation according to IEC 607213K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2
shock resistance according to IEC 60068-2-2715g / 11 ms; with basic unit snapped on
● finely stranded with core end processing1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)
installation altitude at height above sea level
Input for analogue temperature sensor (EF007114)-
Rated control supply voltage Us at DC (EF003980)-
● with degree of pollution 3 at AC rated value690 V
EMC emitted interference according to IEC 60947-1class A
diameter of inlet opening for current measurement14 mm
field-based interference according to IEC 61000-4-310 V/m
Region Specific PriceGroup / Headquarter Price Group42J / 42J
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
number of outputs as contact-affected switching element0
tightening torque at the measurement inputs for voltage0.5 ... 0.6 N·m
● due to conductor-earth surge according to IEC 61000-4-52 kV
(electrically) protective separation according to IEC 60947-1All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
● due to conductor-conductor surge according to IEC 61000-4-51 kV
tightening torque [lbf·in] at the measurement inputs for voltage4.4 ... 5.3 lbf·in
● for wires of main circuit according to IEC 60947-1 rated value6 kV
type of electrical connection at the measurement inputs for voltagescrew-type terminals
current measuring range extension with external current transformersNo
Compliance with the substance restrictions according to RoHS directiveSince: 28.05.2009
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-oneBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
explosion device group and category according to ATEX directive 2014/34/EUII (2) G, II (2 ) D, I (M2)
measurable supply voltage between the line conductors at AC maximum rated value690 V
line conductors and neutral conductors internal resistance for voltage measurement1 MΩ; RC-based voltage divider
type of connectable conductor cross-sections at the measurement inputs for voltage
Type of electrical connection for auxiliary- and control current circuit (EF006979)Screw connection
adjustable current response value current of the current-dependent overload release10 ... 115 A
General Product ApprovalEMCConfirmationFor use in hazardous locationsDeclaration of ConformityTest CertificatesSpecial Test CertificateTest CertificatesMarine / ShippingType Test Certificates/Test ReportSpecial Test CertificateotherConfirmationPROFINET-CertificationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide