| Parameter | Value |
|---|---|
| EAN | 4047621058566 |
| UPC | 804766730559 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 124 mm |
| width | 45 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 111 mm |
| ● top | 40 mm |
| ● left | 0 mm |
| ● right | 0 mm |
| ● solid | 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) |
| Group Code | R711 |
| ● bottom | 40 mm |
| ● at 24 V | 6 A |
| ● at 60 V | 0.55 A |
| Confirmation | |
| Metal Factor | None |
| ● at 120 V | 6 A |
| ● at 125 V | 0.25 A |
| ● at 230 V | 3 A |
| Date5/14/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 5836 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| ● 1 maximum | 2 000 m |
| ● 2 maximum | 3 000 m; max. +50 °C (no protective separation) |
| ● 3 maximum | 4 000 m; max. +40 °C (no protective separation) |
| ● at 50 °C | 6 A |
| ● at 60 °C | 5 A |
| Commodity Code | 85371098 |
| Product family | SIMOCODE pro 3UF7 motor management and control devices |
| last modified: | 4/8/2022 |
| ● web server | Yes |
| Net Weight (kg) | 0,343 Kg |
| ● rated value | 24 V |
| fastening method | screw and snap-on mounting |
| number of inputs | 4 |
| product function | |
| required spacing | |
| shock resistance | |
| ● control unit | Yes |
| ● direct start | Yes |
| ● relay output | Yes |
| Country of origin | Germany |
| Test Certificates | Marine / Shipping |
| mounting position | any |
| number of outputs | 3 |
| product component | |
| product extension | |
| relative humidity | |
| ● digital input | Yes |
| ● initial value | 0.85 |
| ● shared device | No |
| ● slide control | No |
| ● test function | Yes |
| ● valve control | No |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| switching behavior | monostable |
| ● I&M3 - comment | Yes |
| ● during storage | -40 ... +80 °C |
| Packaging Dimension | 52,00 x 132,00 x 134,00 |
| Product Description | Basic unit SIMOCODE pro V PN GP , Ethernet/PROFINET IO, PN system redundancy, OPC UA server, Web server, transmission rate 100 Mbps, 1 x bus connection via RJ45, 4 I/3 Q freely parameterizable, Us: 24 V DC, input for thermistor connection Monostable relay outputs, expandable by 1 extension module(DM, TM, EM) |
| ambient temperature | |
| inrush current peak | |
| product designation | Motor management system |
| protection class IP | IP20 |
| number of interfaces | |
| ● during operation | -25 ... +60 °C |
| ● during transport | -40 ... +80 °C |
| ● full-scale value | 1.2 |
| ● reverse starting | Yes |
| consumed active power | 3.9 W |
| design of the product | basic unit 3 |
| transfer rate maximum | 100 Mbit/s |
| type of relay outputs | Monostable |
| ● Dahlander circuit | No |
| ● analog I/O module | No |
| ● bus communication | Yes |
| ● current detection | Yes |
| ● voltage detection | No |
| conducted interference | |
| environmental category | |
| ● star-delta circuit | Yes |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● asymmetry detection | Yes |
| ● at AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
| ● overload protection | Yes |
| ● password protection | Yes |
| General Product Approval | EMC |
| Special Test Certificate | Special Test Certificate |
| product type designation | SIMOCODE pro V PN GP |
| ● diagnostics function | Yes |
| ● maintenance function | Yes |
| ● vibration resistance | 1-6 Hz / 15 mm; 6-500 Hz / 2 g |
| PROFINET conformity class | B |
| ● according to PROFIBUS | 0 |
| ● according to PROFINET | 1 |
| ● overvoltage detection | No |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| certificate of suitability | |
| ● at AWG cables stranded | 1x (20 ... 14), 2x (20 ... 16) |
| ● ground fault detection | Yes |
| ● parameterizable inputs | Yes |
| ● undervoltage detection | No |
| Standard lead time ex-works | 1 Day/Days |
| Surcharge for Raw Materials | None |
| ● active power monitoring | No |
| ● circuit breaker control | Yes |
| ● parameterizable outputs | Yes |
| ● phase failure detection | Yes |
| ● power factor monitoring | No |
| Package size unit of measure | MM |
| control supply voltage at DC | |
| type of input characteristic | Type 1 in accordance with EN 61131-2 |
| ● I&M2 - installation date | Yes |
| ● according to Ethernet/IP | 0 |
| ● current measuring module | Yes |
| Substance Prohibitance (Date) | 08/31/2018 |
| ● control unit with display | No |
| ● data acquisition function | Yes |
| ● for thermistor connection | 1 |
| ● protocol is supported NTP | Yes |
| For use in hazardous locations | Declaration of Conformity |
| ● phase sequence recognition | No |
| ● protocol is supported LLDP | Yes |
| ● protocol is supported SNMP | Yes |
| duration of inrush current peak | |
| number of semiconductor outputs | 0 |
| release value of thermoresistor | 1 500 ... 1 650 Ω |
| ● Dahlander reversing circuit | No |
| ● according to IEC 60068-2-27 | 15g / 11 ms |
| ● blocking current evaluation | Yes |
| ● protocol is supported HTTPS | Yes |
| response value of thermoresistor | 3 400 ... 3 800 Ω |
| ● fail-safe digital I/O module | No |
| ● of the short-circuit control | 9 Ω |
| ● pole-changing switch circuit | No |
| ● star-delta reversing circuit | No |
| ● overcurrent detection 1 phase | Yes |
| ● supports PROFIenergy shutdown | Yes |
| ● temperature monitoring module | Yes |
| ● ground-fault monitoring module | Yes |
| ● parameterizable overload relay | Yes |
| ● undercurrent detection 1 phase | Yes |
| ● input for thermistor connection | Yes |
| surge voltage resistance rated value | 4 000 V |
| ● current/voltage measuring module | No |
| ● input for ground fault detection | No |
| ● protocol is supported Modbus RTU | No |
| Article Number (Market Facing Number) | 3UF7011-1AB00-2 |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3 |
| identification & maintenance function | |
| product function soft starter control | Yes |
| wire length for thermistor connection | |
| ● protocol is supported EtherNet/IP | No |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● I&M0 - device-specific information | Yes |
| reference code according to IEC 81346-2 | F |
| wire length for digital signals maximum | 300 m |
| ● protocol is supported OPC UA Server | Yes |
| ● input for analog temperature sensors | No |
| ● supports PROFIenergy measured values | Yes |
| touch protection against electrical shock | finger-safe |
| ● at the Ethernet interface Autosensing | Yes |
| ● during storage according to IEC 60721 | 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4 |
| control supply voltage 1 at DC rated value | 24 V |
| ● according to ATEX directive 2014/34/EU | BVS 06 ATEX F001 |
| ● pole-changing switch reversing circuit | No |
| tightening torque with screw-type terminals | 0.8 ... 1.2 N·m |
| ● at the Ethernet interface Autocrossover | Yes |
| ● due to burst according to IEC 61000-4-4 | 2 kV (power ports) / 1 kV (signal ports) |
| ● during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ● during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 |
| ● is supported PROFINET system redundancy | Yes; S2 in conjunction with SIMATIC PCS 7 CPU 410-5H |
| buffering time in the event of power failure | 0.02 s |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| ● monitoring of number of start operations | Yes |
| ● protocol is supported PROFIsafe protocol | No |
| design of short-circuit protection per output | Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A) |
| type of voltage of the control supply voltage | DC |
| ● at the Ethernet interface Autonegotiation | Yes |
| ● evaluation of thermistor motor protection | Yes |
| digital input version type 1 acc. to IEC 61131 | Yes |
| ● protocol is supported PROFIBUS DP protocol | No |
| ● protocol is supported PROFINET IO protocol | Yes |
| electrical endurance (switching cycles) typical | 100 000 |
| installation altitude at height above sea level | |
| input voltage at digital input at DC rated value | 24 V |
| EMC emitted interference according to IEC 60947-1 | class A |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| mechanical service life (switching cycles) typical | 10 000 000 |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| ● with conductor cross-section = 0.5 mm² maximum | 50 m |
| ● with conductor cross-section = 1.5 mm² maximum | 150 m |
| ● with conductor cross-section = 2.5 mm² maximum | 250 m |
| Region Specific PriceGroup / Headquarter Price Group | 42J / 42J |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| tightening torque [lbf·in] with screw-type terminals | 7 ... 10.3 lbf·in |
| number of outputs as contact-affected switching element | 3 |
| conducted HF interference emissions according to CISPR11 | corresponds to degree of severity A |
| field-bound HF interference emission according to CISPR11 | corresponds to degree of severity A |
| total cold resistance number of sensors in series maximum | 1.5 kΩ |
| ● product function is supported Device Level Ring (DLR) | No |
| ● protocol is supported Media Redundancy Protocol (MRP) | No |
| continuous current of the NO contacts of the relay outputs | |
| number of digital inputs with a common reference potential | 4 |
| ● I&M1 – higher level designation/location designation | Yes |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| ● protocol is supported Address Resolution Protocol (ARP) | Yes |
| type of electrical connection of the communication interface | 1 x RJ45 |
| ● Media Redundancy Protocol for Planned Duplication (MRPD) | No |
| (electrically) protective separation according to IEC 60947-1 | All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information) |
| ● due to high-frequency radiation according to IEC 61000-4-6 | 10 V |
| insulation voltage with degree of pollution 3 at AC rated value | 300 V |
| operating range factor control supply voltage rated value at DC | |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| Compliance with the substance restrictions according to RoHS directive | Since: 31.08.2018 |
| product component removable terminal for auxiliary and control circuit | Yes |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| explosion device group and category according to ATEX directive 2014/34/EU | II (2) G, II (2 ) D, I (M2) |
| switching capacity current of the NO contacts of the relay outputs at AC-15 | |
| switching capacity current of the NO contacts of the relay outputs at DC-13 | |
| General Product ApprovalEMCConfirmationFor use in hazardous locationsDeclaration of ConformityTest CertificatesType Test Certificates/Test ReportTest CertificatesMarine / ShippingSpecial Test CertificateSpecial Test CertificateotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide