| Parameter | Value |
|---|---|
| EAN | 4011209896123 |
| UPC | 887621125509 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 124.3 mm |
| width | 45 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 105.9 mm |
| ● at AC | |
| ● at DC | 110 ... 240 V |
| ● solid | 0.5 ... 4 mm² |
| Group Code | R711 |
| — at 24 V | 2 A |
| Date5/7/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | LAO----- |
| — at 115 V | 3 A |
| — at 230 V | 3 A |
| — at 50 Hz | 0.8 ... 1.1 |
| — at 60 Hz | 0.8 ... 1.1 |
| ● at 50 Hz | 110 ... 240 V |
| ● at 60 Hz | 110 ... 240 V |
| ● stranded | 2x (20 ... 14) |
| Product Group | 5837 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| ● 2-channel | 3 |
| Commodity Code | 85364900 |
| Product family | With special functions |
| last modified: | 4/11/2022 |
| Net Weight (kg) | 0,439 Kg |
| design of input | |
| ● UL approval | Yes |
| ● start input | Yes |
| Depth (EF000049) | 124.3 |
| Model (EF000010) | Other |
| Width (EF000008) | 45.0 |
| fastening method | screw and snap-on mounting |
| product function | |
| shock resistance | 8g / 10 ms |
| Country of origin | Germany |
| Height (EF000040) | 105.9 |
| Test Certificates | other |
| mounting position | any |
| ● 1 rated value | 50 Hz |
| ● 2 rated value | 60 Hz |
| ● as NC contact | |
| ● as NO contact | |
| ● safety switch | Yes |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| ● during storage | -20 ... +70 °C |
| ● feedback input | Yes |
| ● for signal <1> | 1.8 mA |
| ● safety-related | |
| Packaging Dimension | 113,00 x 131,00 x 57,00 |
| Product Description | SIRIUS safety relay Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical NAMUR version Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3 |
| ambient temperature | |
| measuring precision | +-2 % |
| product designation | Speed monitor |
| suitability for use | |
| ● BG BIA approval | No |
| ● automatic start | Yes |
| ● finely stranded | |
| ● with signal <0> | 1.6 mA |
| switching hysteresis | 6.25 % |
| ● during operation | 0 ... 60 °C |
| ● valve monitoring | No |
| design of the product | standstill and speed monitoring |
| — delayed switching | 0 |
| performance level (PL) | |
| ● monitored start-up | Yes |
| Product Lifecycle (PLM) | PM300:Active Product |
| design of the cascading | none |
| number of sensor inputs | |
| EMC emitted interference | EN 60947-5-1 |
| General Product Approval | Declaration of Conformity |
| Release-delay (EF001129) | - |
| Special Test Certificate | Confirmation |
| control supply voltage 1 | |
| encoder signal evaluation | two signal tracks each with inverted signals |
| — instantaneous contact | 0 |
| ● standstill monitoring | Yes |
| Export Control Regulations | AL : N / ECCN : N |
| certificate of suitability | EN ISO 13849, EN 62061, IEC 61508 |
| switching capacity current | |
| ● 1-channel or 2-channel | 0 |
| ● EMERGENCY OFF function | Yes |
| ● according to IEC 61508 | 3 |
| ● according to IEC 62061 | 3 |
| ● for signaling function | |
| ● light array monitoring | No |
| Standard lead time ex-works | 20 Day/Days |
| Surcharge for Raw Materials | None |
| With start input (EF003342) | true |
| ● for cable break maximum | 0.15 mA |
| ● safety-related circuits | Yes |
| Evaluation inputs (EF008245) | 2-channel |
| Package size unit of measure | MM |
| Safety Integrity Level (SIL) | |
| — with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| ● according to ISO 13849-1 | e |
| ● laser scanner monitoring | No |
| ● light barrier monitoring | No |
| ● of semiconductor outputs | |
| ● on short circuit minimum | 6 mA |
| type of electrical connection | screw-type terminals |
| ● rotation speed monitoring | Yes |
| ● tactile sensor monitoring | No |
| control supply voltage 1 at AC | |
| insulation voltage rated value | 300 V |
| ● position switch monitoring | Yes |
| ● protective door monitoring | Yes |
| With muting function (EF004057) | false |
| supply voltage of NAMUR sensors | 8.2 V; provided by the device |
| With feedback circuit (EF003343) | true |
| control supply voltage frequency | |
| Rail mounting possible (EF003972) | FALSE |
| With approval for TÜV (EF004144) | true |
| With detachable clamps (EF003340) | true |
| air pressure according to SN 31205 | 90 ... 106 kPa |
| relative humidity during operation | 10 ... 95 % |
| ● monitoring of floating sensors | Yes |
| With approval for BG BIA (EF004145) | false |
| product feature cross-circuit-proof | Yes |
| type of signal level of the encoder | optionally TTL, HTL or sin/cos (Ua = 1Vss) |
| category according to EN ISO 13849-1 | 4 |
| protection class IP of the enclosure | IP20 |
| surge voltage resistance rated value | 4 000 V |
| — safety-related delayed switching | 0 |
| ● EMERGENCY-OFF circuit monitoring | No |
| Article Number (Market Facing Number) | 3TK2810-1KA41-0AA0 |
| SIL according to IEC 61508 (EF009889) | 3 |
| Voltage type for actuating (EF008242) | AC/DC |
| stop category according to EN 60204-1 | 0 |
| ● pressure-sensitive mat monitoring | No |
| Type of electric connection (EF003961) | Screw connection |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| installation environment regarding EMC | This product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case. |
| reference code according to EN 61346-2 | F |
| ● monitoring of non-floating sensors | No |
| pulse duration of NAMUR sensors minimum | 75 µs |
| type of failure response of the encoder | high-resistance |
| With approval according to UL (EF001783) | true |
| — safety-related instantaneous contact | 0 |
| ● cascading input/functional switching | No |
| Category according to EN 954-1 (EF006782) | 4 |
| suitability for interaction press control | No |
| touch protection against electrical shock | finger-safe |
| interpulse period of NAMUR sensors minimum | 75 µs |
| safety device type according to IEC 61508-2 | Type B |
| — for signaling function at DC-13 at 24 V | 0.02 A |
| ● magnetically operated switch monitoring | No |
| Suitable for monitoring of valves (EF007272) | false |
| type of connectable conductor cross-sections | |
| — for signaling function delayed switching | 0 |
| type of voltage of the control supply voltage | AC/DC |
| Stop category according to IEC 60204 (EF007498) | 0 |
| electrical endurance (switching cycles) typical | 100 000 |
| hardware fault tolerance according to IEC 61508 | 1 |
| type of the safety-related wiring of the inputs | single-channel or two-channel |
| vibration resistance according to IEC 60068-2-6 | 10 ... 55 Hz: 0.35 mm |
| PFHD with high demand rate according to EN 62061 | 0.0000000034 1/h |
| Rated control supply voltage Us at DC (EF003980) | ['110', '240'] |
| — for signaling function instantaneous contact | 0 |
| SIL Claim Limit (subsystem) according to EN 62061 | 3 |
| ● magnetically operated switch monitoring NC-NC | No |
| ● magnetically operated switch monitoring NC-NO | No |
| Type of safety according to IEC 61496-1 (EF004105) | - |
| mechanical service life (switching cycles) typical | 50 000 000 |
| Region Specific PriceGroup / Headquarter Price Group | 41L / 41L |
| ● TÜV (German technical inspectorate) certificate | Yes |
| ● of the NC contacts of the relay outputs at AC-15 | |
| ● of the NO contacts of the relay outputs at AC-15 | |
| ● of the NO contacts of the relay outputs at DC-13 | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110', '240'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['110', '240'] |
| Suitable for monitoring of tactile sensors (EF007271) | false |
| adjustment range of signal frequency of NAMUR sensors | 1 Hz ... 2 kHz |
| type of voltage of the supply voltage of NAMUR sensors | DC |
| ● for delayed release circuit according to IEC 61508 | SIL3 |
| Suitable for monitoring of magnetic switches (EF007266) | false |
| Suitable for monitoring of position switches (EF007270) | true |
| installation altitude at height above sea level maximum | 2 000 m |
| number of outputs as contact-affected switching element | |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e |
| Suitable for monitoring of proximity switches (EF007267) | true |
| type of connectable conductor cross-sections at AWG cables | |
| ● for delayed release circuit according to EN ISO 13849-1 | e |
| Suitable for monitoring of emergency-stop circuits (EF007268) | false |
| thermal current of the switching element with contacts maximum | 5 A |
| switching threshold for input current at input of NAMUR sensors | |
| number of outputs as contact-less semiconductor switching element | |
| Number of outputs, safety related, delayed, with contact (EF003345) | - |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | 0 |
| Number of outputs, safety related, undelayed, with contact (EF003344) | - |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 0 |
| T1 value for proof test interval or service life according to IEC 61508 | 20 y |
| Number of outputs, signalling function, delayed, with contact (EF003349) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| operating range factor control supply voltage rated value of magnet coil | |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | false |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | 1 |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | - |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | 1 |
| reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | KT |
| design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required | gL/gG: 4 A |
| General Product ApprovalDeclaration of ConformityTest CertificatesotherRailwaySpecial Test CertificateConfirmationConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide