Service time: Monday to Friday 9:00-18:00
3TK2810-0JA02 - 3TK2810-0JA02 SIEMENS SIRIUS safety relay safety-oriented Standstill monitoring 400 V AC, 45 mm Spring-type ..
In Stock Hot Product

3TK2810-0JA02

3TK2810-0JA02 SIEMENS SIRIUS safety relay safety-oriented Standstill monitoring 400 V AC, 45 mm Spring-type ..

$0.00USD
3533 in stock
Key Specifications
:
EAN:4011209725218
UPC:754554946443
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209725218
UPC754554946443
ETIM5
IDEA4
depth120 mm
width45 mm
UNSPSC14
eClass6
height138.5 mm
● at AC
● solid2x (0.25 ... 1.5 mm²)
Group CodeR711
— at 24 V2 A
● maximum690 V
Date5/3/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
— at 115 V3 A
— at 230 V3 A
— at 50 Hz0.8 ... 1.1
— at 60 Hz0.8 ... 1.1
● stranded2x (20 ... 16)
Product Group5837
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85364900
Product familyWith special functions
last modified:4/1/2022
Net Weight (kg)0,509 Kg
design of input
● UL approvalYes
● start inputNo
Depth (EF000049)120.0
Model (EF000010)Other
Width (EF000008)45.0
fastening methodscrew and snap-on mounting
product function
shock resistance8g / 10 ms
Country of originGermany
Height (EF000040)138.5
Test Certificatesother
mounting positionany
● 1 rated value50 Hz
● 2 rated value60 Hz
● as NC contact
● as NO contact
● safety switchYes
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-40 ... +75 °C
● feedback inputYes
● safety-related
Packaging Dimension112,00 x 127,00 x 55,00
Product DescriptionSIRIUS safety relay safety-oriented Standstill monitoring 400 V AC, 45 mm Spring-type terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
adjustable downtime0.2 ... 6 s
ambient temperature
product designationStandstill monitor
suitability for use
● BG BIA approvalYes
● automatic startNo
● finely stranded
● during operation-25 ... +60 °C
● valve monitoringNo
design of the productfor safe stoppage monitoring
— delayed switching0
performance level (PL)
● monitored start-upNo
Product Lifecycle (PLM)PM300:Active Product
design of the cascadingnone
number of sensor inputs
EMC emitted interferenceIEC 61000-6-2, IEC 61000-6-3
General Product ApprovalFunctional Safety/Safety of Machinery
Release-delay (EF001129)-
Special Test CertificateConfirmation
● at 50 Hz rated value400 V
● at 60 Hz rated value400 V
— instantaneous contact0
● standstill monitoringYes
Export Control RegulationsAL : N / ECCN : N
certificate of suitabilityUL, CSA, EN 60204-1, EN ISO 12100, EN 954-1, IEC 61508
switching capacity current
● 1-channel or 2-channel1
● EMERGENCY OFF functionNo
● according to IEC 615083
● according to IEC 620613
● for signaling function
● light array monitoringNo
Standard lead time ex-works20 Day/Days
Surcharge for Raw MaterialsNone
With start input (EF003342)false
operating frequency maximum1 200 1/h
● according to UL maximum600 V
● safety-related circuitsYes
Evaluation inputs (EF008245)Other
Package size unit of measureMM
Safety Integrity Level (SIL)
— with core end processing2 x (0.25 ... 1.5 mm²)
● according to ISO 13849-1e
● laser scanner monitoringNo
● light barrier monitoringNo
● of semiconductor outputs
type of electrical connectionspring-loaded terminals
● rotation speed monitoringNo
● tactile sensor monitoringNo
control supply voltage 1 at AC
insulation voltage rated value690 V
● position switch monitoringNo
● protective door monitoringNo
With muting function (EF004057)false
— without core end processing2x (0.25 ... 1.5 mm²)
With feedback circuit (EF003343)true
control supply voltage frequency
Rail mounting possible (EF003972)FALSE
With approval for TÜV (EF004144)true
With detachable clamps (EF003340)true
air pressure according to SN 3120590 ... 106 kPa
relative humidity during operation10 ... 95 %
With approval for BG BIA (EF004145)true
product feature cross-circuit-proofNo
protection class IP of the terminalIP20
category according to EN ISO 13849-14
protection class IP of the enclosureIP20
surge voltage resistance rated value6 000 V
— safety-related delayed switching0
● EMERGENCY-OFF circuit monitoringNo
Article Number (Market Facing Number)3TK2810-0JA02
SIL according to IEC 61508 (EF009889)3
Voltage type for actuating (EF008242)AC
stop category according to EN 60204-10
● pressure-sensitive mat monitoringNo
Type of electric connection (EF003961)Other
WEEE (2012/19/EU) Take-Back ObligationYes
installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
reference code according to EN 61346-2F
With approval according to UL (EF001783)true
— safety-related instantaneous contact4
● cascading input/functional switchingNo
Category according to EN 954-1 (EF006782)4
suitability for interaction press controlNo
touch protection against electrical shockfinger-safe
input resistance at the measurement inputs500 kΩ
safety device type according to IEC 61508-2Type B
— for signaling function at DC-13 at 24 V0.1 A
● magnetically operated switch monitoringNo
Suitable for monitoring of valves (EF007272)false
type of connectable conductor cross-sections
type of electrical connection plug-in socketYes
type of voltage of the control supply voltageAC
Stop category according to IEC 60204 (EF007498)0
electrical endurance (switching cycles) typical200 000
hardware fault tolerance according to IEC 615081
type of the safety-related wiring of the inputsmeasuring inputs
vibration resistance according to IEC 60068-2-610 ... 55 Hz: 0.35 mm
PFHD with high demand rate according to EN 620610.0000000015 1/h
Rated control supply voltage Us at DC (EF003980)['-', '-']
— for signaling function instantaneous contact2
SIL Claim Limit (subsystem) according to EN 620613
● magnetically operated switch monitoring NC-NCNo
● magnetically operated switch monitoring NC-NONo
Type of safety according to IEC 61496-1 (EF004105)-
mechanical service life (switching cycles) typical50 000 000
Region Specific PriceGroup / Headquarter Price Group41L / 41L
● TÜV (German technical inspectorate) certificateYes
● of the NC contacts of the relay outputs at AC-15
● of the NC contacts of the relay outputs at DC-13
● of the NO contacts of the relay outputs at AC-15
● of the NO contacts of the relay outputs at DC-13
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '400']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '400']
Suitable for monitoring of tactile sensors (EF007271)false
● for delayed release circuit according to IEC 61508SIL3
Suitable for monitoring of magnetic switches (EF007266)false
Suitable for monitoring of position switches (EF007270)false
installation altitude at height above sea level maximum2 000 m
number of outputs as contact-affected switching element
voltage measuring range at the measurement inputs at AC
Performance level according to EN ISO 13849-1 (EF007399)Level e
Suitable for monitoring of proximity switches (EF007267)false
adjustable response value voltage for standstill detection20 ... 400 mV
type of connectable conductor cross-sections at AWG cables
Suitable for monitoring of emergency-stop circuits (EF007268)false
thermal current of the switching element with contacts maximum5 A
number of outputs as contact-less semiconductor switching element
Number of outputs, safety related, delayed, with contact (EF003345)-
Number of outputs, safety related, delayed, semiconductors (EF003347)0
Number of outputs, safety related, undelayed, with contact (EF003344)-
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Number of outputs, safety related, undelayed, semiconductors (EF003346)0
T1 value for proof test interval or service life according to IEC 6150820 y
Number of outputs, signalling function, delayed, with contact (EF003349)-
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
operating range factor control supply voltage rated value of magnet coil
Suitable for monitoring of optoelectronic protection equipment (EF007269)false
Number of outputs, signalling function, delayed, semiconductors (EF003351)0
Number of outputs, signalling function, undelayed, with contact (EF003348)-
Number of outputs, signalling function, undelayed, semiconductors (EF003350)2
Average probability of failure on demand (PFDavg) with low demand rate acc. to IEC 615080.002 1/y
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750KT
design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requiredquick: 5 A
General Product ApprovalFunctional Safety/Safety of MachineryDeclaration of ConformityType Examination CertificateTest CertificatesotherRailwaySpecial Test CertificateConfirmationConfirmationGeneral Product Approval

Product Description

SIRIUS Relay security, zero speed surveillance, 400V AC, spring connection, 3NA/1NC enablement, 1CO/2 elec outputs. signage
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top