Service time: Monday to Friday 9:00-18:00
3TC5617-0BF0 - 3TC5617-0BF0 SIEMENS Contactor, size 12, 2-pole, DC-3 and 5, 400 A Auxiliary switch 22 (2 NO + 2 NC) 110V AC..
In Stock Hot Product

3TC5617-0BF0

3TC5617-0BF0 SIEMENS Contactor, size 12, 2-pole, DC-3 and 5, 400 A Auxiliary switch 22 (2 NO + 2 NC) 110V AC..

$0.00USD
3870 in stock
Key Specifications
:Confirmation
EAN:4011209129146
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209129146
UPCNot available
ETIM5
IDEA4
depth255 mm
width160 mm
UNSPSC15
eClass6
height281 mm
● at AC12g / 5 ms, 5,6g / 10 ms
Group CodeR711
arcing time20 ... 30 ms
— upwards10 mm
● at DC-1
Metal FactorLDO-----
— forwards25 mm
● at 50 Hz0.8 ... 1.1
● at 60 Hz2 140 VA
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group5807
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
— backwards0 mm
— downwards10 mm
Commodity Code85364900
Product family3TC contactors for switching DC voltage, 1-pole and 2-pole
last modified:12/2/2021
Net Weight (kg)14,363 Kg
number of poles2
operating power
type of voltageDC
— at the side10 mm
fastening methodscrew fixing
required spacing
Country of originGermany
Marine / Shippingother
mounting position+/-22,5° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface; standing, on horizontal mounting surface
product extension
size of contactor12
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
● during storage-50 ... +80 °C
● for live parts
Packaging Dimension374,00 x 404,00 x 298,00
Product DescriptionContactor, size 12, 2-pole, DC-3 and 5, 400 A Auxiliary switch 22 (2 NO + 2 NC) 110V AC 50Hz/132V AC 60Hz AC operation AC operation
ambient temperature
operating frequency
operational current
product designationContactor
● at DC-1 maximum1 000 1/h
● at DC-3 at DC-5
● at DC-3 maximum600 1/h
● at DC-5 maximum600 1/h
● auxiliary switchYes
● during operation-25 ... +55 °C
— solid or stranded2x (1 ... 2,5 mm²)
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
— at 24 V rated value400 A
● at 24 V rated value10 A
● at 48 V rated value10 A
● at 60 V rated value10 A
General Product ApprovalFunctional Safety/Safety of Machinery
product type designation3TC
— at 110 V rated value400 A
— at 220 V rated value400 A
— at 440 V rated value400 A
— at 600 V rated value400 A
— at 750 V rated value400 A
● at 110 V rated value8 A
● at 125 V rated value6 A
● at 220 V rated value2 A
● at 230 V rated value5.6 A
● at 400 V rated value3.6 A
● at 50 Hz rated value110 V
● at 500 V rated value2.5 A
● at 60 Hz rated value132 V
● at 600 V rated value0.4 A
● of contactor typical10 000 000
relative humidity minimum10 %
● instantaneous contact2
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : N
Modular version (EF001126)true
● for auxiliary contacts
Standard lead time ex-works15 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
Type Examination CertificateUK Declaration of Conformity
control supply voltage at AC
operational current at AC-15
operational current at DC-12
operational current at DC-13
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)05/01/2012
type of electrical connectionscrew-type terminals
● at 1 current path at DC-1
insulation voltage rated value1 000 V
● with side-by-side mounting
operational current at AC-12 maximum10 A
Article Number (Market Facing Number)3TC5617-0BF0
Functional Safety/Safety of MachineryDeclaration of Conformity
Voltage type for actuating (EF008242)AC
● at 1 current path at DC-3 at DC-5
● for auxiliary and control circuitscrew-type terminals
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 required2 x 3NE1330-4D (315 A) parallel (750 V, 12 kA)
number of NC contacts for main contacts0
number of NO contacts for main contacts2
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
number of poles for main current circuit2
— with type of coordination 1 required2 x 3NE1330-4D (315 A) parallel (750 V, 12 kA)
mechanical service life (switching cycles)
● with 2 current paths in series at DC-1
apparent holding power of magnet coil at AC121 VA
apparent pick-up power of magnet coil at AC1 780 VA
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts2
number of NO contacts for auxiliary contacts2
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.75 ... 1.5 mm²)
type of voltage of the control supply voltageAC
Rated control supply voltage Us at DC (EF003980)['-', '-']
● with 2 current paths in series at DC-3 at DC-5
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / P600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
● for short-circuit protection of the main circuit
Rated control supply voltage Us at AC 50HZ (EF003978)['110.0', '110.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['132.0', '132.0']
inductive power factor with closing power of the coil0.3
identification number and letter for switching elements22
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
Rated operation power at DC-3 / DC-5 at 440 V (EF007026)140.0
Type of electrical connection of main circuit (EF006819)Screw connection
inductive power factor with the holding power of the coil0.22
product function mirror contact according to IEC 60947-4-1Yes
Number of main contacts as normally open contact (EF001374)2
Number of normally closed contacts as main contact (EF001375)0
Rated operation current Ie at DC-3 / DC-5 at 440 V (EF007035)400
● of the contactor with added auxiliary switch block typical10 000 000
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Number of auxiliary contacts as normally open contact (EF001376)2
● for short-circuit protection of the auxiliary switch requiredgG: 16 A (500 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)2
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value of magnet coil at AC
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1660 V
General Product ApprovalFunctional Safety/Safety of MachineryConfirmationType Examination CertificateFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesType Examination CertificateUK Declaration of ConformitySpecial Test CertificateMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherDangerous GoodConfirmationTransport InformationGeneral Product Approval

Product Description

SIRIUS Contactor TAMANO 12, 2 poles DC-3 AND 5, 400ASIRIUS AUXILIYL contactors. 22 (2NA+2NC) ACCIONAM. BY ALTERNATING CURRENT AC 110V 50HZ/AC 132V 60HZ. Manufactured to order. Non-Cancelable Non-Retur
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top