3TC4417-0BK6 - 3TC4417-0BK6 SIEMENS Contactor size 2, 2-pole DC-3 and 5, 32 A Auxiliary switch 22 (2 NO + 2 NC) Alternating..
In Stock Hot Product

3TC4417-0BK6

3TC4417-0BK6 SIEMENS Contactor size 2, 2-pole DC-3 and 5, 32 A Auxiliary switch 22 (2 NO + 2 NC) Alternating..

$0.00USD
4250 in stock
Key Specifications
:Value
EAN:4011209142244
UPC:754554957500
Depth:104 mm
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209142244
UPC754554957500
Depth104 mm
Width70 mm
Height85 mm
● at AC7,5g / 5 ms, 3,4g / 10 ms
Group CodeR711
Arcing time20 ... 30 ms
Price Group41B
— upwards10 mm
● at DC-1
Metal FactorLDO-----
— forwards15 mm
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.85 ... 1.1
MiscellaneousSpecial Test Certificate
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Product Group5807
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
— Backwards0 mm
— downwards10 mm
Commodity Code85364900
Product familyNot available
last modified:08/13/2020
Net Weight (kg)0,692 Kg
Operating power
number of poles2
type of voltageDC
— at the side10 mm
Required spacing
Country of originGermany
Operating current
Product extension
Size of contactor2
mounting position+/-22,5° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface; standing, on horizontal mounting surface
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
● during storage-50 ... +80 °C
● for live parts
Ambient temperature
Operating frequency
Packaging Dimension77,00 x 93,00 x 130,00
Product DescriptionContactor size 2, 2-pole DC-3 and 5, 32 A Auxiliary switch 22 (2 NO + 2 NC) Alternating current operation 120 V AC 60 Hz/110 V AC 50 Hz
Product designationContactor
● at DC-1 maximum1 500 1/h
● at DC-3 at DC-5
● at DC-3 maximum750 1/h
● at DC-5 maximum750 1/h
● Auxiliary switchYes
● during operation-25 ... +55 °C
Number of CO contacts
● for main contacts
● for grounded parts
Design of the fuse link
Product Lifecycle (PLM)PM300:Active Product
— at 24 V rated value32 A
● Protection class IPIP00
● at 24 V rated value10 A
● at 48 V rated value10 A
● at 60 V rated value10 A
General Product ApprovalFunctional Safety/Safety of Machinery
Product type designation3TC
— at 110 V rated value32 A
— at 220 V rated value32 A
— at 440 V rated value32 A
— at 600 V rated value32 A
— at 750 V rated value7.5 A
● at 110 V rated value3.2 A
● at 125 V rated value2.5 A
● at 220 V rated value0.9 A
● at 230 V rated value5.6 A
● at 400 V rated value3.6 A
● at 50 Hz rated value110 V
● at 500 V rated value2.5 A
● at 60 Hz rated value120 V
● at 600 V rated value0.22 A
● of contactor typical10 000 000
Declaration of ConformityTest Certificates
● Side-by-side mountingYes
● instantaneous contact2
Export Control RegulationsECCN : N / AL : N
Modular version (EF001126)true
Operating current at AC-15
Operating current at DC-12
Operating current at DC-13
● for auxiliary contacts0
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
Control supply voltage at AC
Package size unit of measureMM
— single or multi-stranded2x (2,5 ... 10 mm²)
Insulation voltage rated value800 V
Product Dimensions (W x L x H)Not available
● with side-by-side mounting
● type of electrical connectionscrew-type terminals
Operating current at AC-12 maximum10 A
Protection against electrical shockfinger-safe only with terminal cover
● protection class IP on the frontIP00
Article Number (Market Facing Number)3TC4417-0BK6
Reference code acc. to DIN EN 81346-2Q
Voltage type for actuating (EF008242)AC
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgG: 35 A (690 V, 100 kA)
Number of NC contacts for main contacts0
Number of NO contacts for main contacts2
Shock resistance at rectangular impulse
● Protection class IP of the terminalIP00
Number of poles for main current circuit2
— with type of coordination 1 requiredgG: 50 A (690 V, 100 kA)
contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
Mechanical service life (switching cycles)
● with 2 current paths in series at DC-1
Apparent holding power of magnet coil at AC11 V·A
Apparent pick-up power of magnet coil at AC79 V·A
Number of NC contacts for auxiliary contacts2
Number of NO contacts for auxiliary contacts2
Type of connectable conductor cross-sections
— finely stranded with core end processing2x (1.5 ... 4 mm²)
Type of voltage of the control supply voltageAC
Rated control supply voltage Us at DC (EF003980)['-', '-']
● with 2 current paths in series at DC-3 at DC-5
Contact rating of auxiliary contacts according to ULA600 / P600
● for short-circuit protection of the main circuit
Inductive power factor with closing power of the coil0.83
Rated control supply voltage Us at AC 50HZ (EF003978)['110.0', '110.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['120.0', '120.0']
Identification number and letter for switching elements22
Rated operation power at DC-3 / DC-5 at 440 V (EF007026)9.0
Type of electrical connection of main circuit (EF006819)Screw connection
Inductive power factor with the holding power of the coil0.28
● Type of electrical connection for main current circuitscrew-type terminals
Number of main contacts as normally open contact (EF001374)2
Number of normally closed contacts as main contact (EF001375)0
Rated operation current Ie at DC-3 / DC-5 at 440 V (EF007035)29
● of the contactor with added auxiliary switch block typical10 000 000
Number of auxiliary contacts as normally open contact (EF001376)2
● for short-circuit protection of the auxiliary switch requiredgG: 16 A (500 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)2
Compliance with the substance restrictions according to RoHS directiveSince: 01.02.2012
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● Type of electrical connection for auxiliary and control current circuitscrew-type terminals
Operating range factor control supply voltage rated value of magnet coil at AC
maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1300 V
General Product ApprovalFunctional Safety/Safety of MachineryDeclaration of ConformityType Examination CertificateDeclaration of ConformityTest CertificatesMarine / ShippingotherMiscellaneousSpecial Test CertificateMiscellaneousConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top