| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209142244 |
| UPC | 754554957500 |
| Depth | 104 mm |
| Width | 70 mm |
| Height | 85 mm |
| ● at AC | 7,5g / 5 ms, 3,4g / 10 ms |
| Group Code | R711 |
| Arcing time | 20 ... 30 ms |
| Price Group | 41B |
| — upwards | 10 mm |
| ● at DC-1 | |
| Metal Factor | LDO----- |
| — forwards | 15 mm |
| ● at 50 Hz | 0.8 ... 1.1 |
| ● at 60 Hz | 0.85 ... 1.1 |
| Miscellaneous | Special Test Certificate |
| Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 |
| Product Group | 5807 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| — Backwards | 0 mm |
| — downwards | 10 mm |
| Commodity Code | 85364900 |
| Product family | Not available |
| last modified: | 08/13/2020 |
| Net Weight (kg) | 0,692 Kg |
| Operating power | |
| number of poles | 2 |
| type of voltage | DC |
| — at the side | 10 mm |
| Required spacing | |
| Country of origin | Germany |
| Operating current | |
| Product extension | |
| Size of contactor | 2 |
| mounting position | +/-22,5° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface; standing, on horizontal mounting surface |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| ● during storage | -50 ... +80 °C |
| ● for live parts | |
| Ambient temperature | |
| Operating frequency | |
| Packaging Dimension | 77,00 x 93,00 x 130,00 |
| Product Description | Contactor size 2, 2-pole DC-3 and 5, 32 A Auxiliary switch 22 (2 NO + 2 NC) Alternating current operation 120 V AC 60 Hz/110 V AC 50 Hz |
| Product designation | Contactor |
| ● at DC-1 maximum | 1 500 1/h |
| ● at DC-3 at DC-5 | |
| ● at DC-3 maximum | 750 1/h |
| ● at DC-5 maximum | 750 1/h |
| ● Auxiliary switch | Yes |
| ● during operation | -25 ... +55 °C |
| Number of CO contacts | |
| ● for main contacts | |
| ● for grounded parts | |
| Design of the fuse link | |
| Product Lifecycle (PLM) | PM300:Active Product |
| — at 24 V rated value | 32 A |
| ● Protection class IP | IP00 |
| ● at 24 V rated value | 10 A |
| ● at 48 V rated value | 10 A |
| ● at 60 V rated value | 10 A |
| General Product Approval | Functional Safety/Safety of Machinery |
| Product type designation | 3TC |
| — at 110 V rated value | 32 A |
| — at 220 V rated value | 32 A |
| — at 440 V rated value | 32 A |
| — at 600 V rated value | 32 A |
| — at 750 V rated value | 7.5 A |
| ● at 110 V rated value | 3.2 A |
| ● at 125 V rated value | 2.5 A |
| ● at 220 V rated value | 0.9 A |
| ● at 230 V rated value | 5.6 A |
| ● at 400 V rated value | 3.6 A |
| ● at 50 Hz rated value | 110 V |
| ● at 500 V rated value | 2.5 A |
| ● at 60 Hz rated value | 120 V |
| ● at 600 V rated value | 0.22 A |
| ● of contactor typical | 10 000 000 |
| Declaration of Conformity | Test Certificates |
| ● Side-by-side mounting | Yes |
| ● instantaneous contact | 2 |
| Export Control Regulations | ECCN : N / AL : N |
| Modular version (EF001126) | true |
| Operating current at AC-15 | |
| Operating current at DC-12 | |
| Operating current at DC-13 | |
| ● for auxiliary contacts | 0 |
| Standard lead time ex-works | 10 Day/Days |
| Surcharge for Raw Materials | None |
| Control supply voltage at AC | |
| Package size unit of measure | MM |
| — single or multi-stranded | 2x (2,5 ... 10 mm²) |
| Insulation voltage rated value | 800 V |
| Product Dimensions (W x L x H) | Not available |
| ● with side-by-side mounting | |
| ● type of electrical connection | screw-type terminals |
| Operating current at AC-12 maximum | 10 A |
| Protection against electrical shock | finger-safe only with terminal cover |
| ● protection class IP on the front | IP00 |
| Article Number (Market Facing Number) | 3TC4417-0BK6 |
| Reference code acc. to DIN EN 81346-2 | Q |
| Voltage type for actuating (EF008242) | AC |
| ● function module for communication | No |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| — with type of assignment 2 required | gG: 35 A (690 V, 100 kA) |
| Number of NC contacts for main contacts | 0 |
| Number of NO contacts for main contacts | 2 |
| Shock resistance at rectangular impulse | |
| ● Protection class IP of the terminal | IP00 |
| Number of poles for main current circuit | 2 |
| — with type of coordination 1 required | gG: 50 A (690 V, 100 kA) |
| contact reliability of auxiliary contacts | one incorrect switching operation of 100 million switching operations (17 V, 5 mA) |
| Mechanical service life (switching cycles) | |
| ● with 2 current paths in series at DC-1 | |
| Apparent holding power of magnet coil at AC | 11 V·A |
| Apparent pick-up power of magnet coil at AC | 79 V·A |
| Number of NC contacts for auxiliary contacts | 2 |
| Number of NO contacts for auxiliary contacts | 2 |
| Type of connectable conductor cross-sections | |
| — finely stranded with core end processing | 2x (1.5 ... 4 mm²) |
| Type of voltage of the control supply voltage | AC |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| ● with 2 current paths in series at DC-3 at DC-5 | |
| Contact rating of auxiliary contacts according to UL | A600 / P600 |
| ● for short-circuit protection of the main circuit | |
| Inductive power factor with closing power of the coil | 0.83 |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110.0', '110.0'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['120.0', '120.0'] |
| Identification number and letter for switching elements | 22 |
| Rated operation power at DC-3 / DC-5 at 440 V (EF007026) | 9.0 |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Inductive power factor with the holding power of the coil | 0.28 |
| ● Type of electrical connection for main current circuit | screw-type terminals |
| Number of main contacts as normally open contact (EF001374) | 2 |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Rated operation current Ie at DC-3 / DC-5 at 440 V (EF007035) | 29 |
| ● of the contactor with added auxiliary switch block typical | 10 000 000 |
| Number of auxiliary contacts as normally open contact (EF001376) | 2 |
| ● for short-circuit protection of the auxiliary switch required | gG: 16 A (500 V, 1 kA) |
| Number of auxiliary contacts as normally closed contact (EF001377) | 2 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.02.2012 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| ● Type of electrical connection for auxiliary and control current circuit | screw-type terminals |
| Operating range factor control supply voltage rated value of magnet coil at AC | |
| maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1 | 300 V |
| General Product ApprovalFunctional Safety/Safety of MachineryDeclaration of ConformityType Examination CertificateDeclaration of ConformityTest CertificatesMarine / ShippingotherMiscellaneousSpecial Test CertificateMiscellaneousConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide