Service time: Monday to Friday 9:00-18:00
3SK2122-2AA10 - 3SK2122-2AA10 SIEMENS SIRIUS safety relay Basic unit 3SK2 series 20 F-DI, 4 F-DQ, 2 DQ, 24 V DC Can be param..
In Stock Hot Product

3SK2122-2AA10

3SK2122-2AA10 SIEMENS SIRIUS safety relay Basic unit 3SK2 series 20 F-DI, 4 F-DQ, 2 DQ, 24 V DC Can be param..

$0.00USD
3909 in stock
Key Specifications
:Confirmation
EAN:4047621004587
UPC:804766163906
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4047621004587
UPC804766163906
ETIM5
IDEA4
depth124.5 mm
width45 mm
UNSPSC15
eClass6
height100 mm
● solid1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
Group CodeR711
● at 24 V11 A
● maximum0.05 mA
Date5/8/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorNone
● stranded20 ... 16
Product Group3761
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
● 2-channel0
Commodity Code85371098
Product familySIRIUS 3SK2 basic units
last modified:3/29/2022
Net Weight (kg)0,390 Kg
type of voltageDC
Depth (EF000049)124.5
Model (EF000010)-
Width (EF000008)45.0
fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
input delay time0 ... 150 ms
number of inputs
product categorySafety relay
product function
residual current
shock resistance15g / 11 ms
Country of originGermany
Height (EF000040)100.0
Test Certificatesother
light test period3 ms
mounting positionany
number of outputs
● to the inputs
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-40 ... +80 °C
● safety-related20
● single channel0
● to the outputs
Packaging Dimension111,00 x 153,00 x 62,00
Product DescriptionSIRIUS safety relay Basic unit 3SK2 series 20 F-DI, 4 F-DQ, 2 DQ, 24 V DC Can be parameterized via SIRIUS Safety ES 45 mm overall width Spring-type terminal (push-in) up to SILCL 3 (DIN EN 62061) Up to Performance Level E (ISO 13849-1) Output expansions 3SK1 and fail-safe motor starters 3RM1 via device connector connectable
ambient temperature
degree of pollution3
inrush current peak
product designationBase-Unit
protection class IPIP20
suitability for use
● of the terminalIP20
— shielded maximum1 000 m
● during operation-25 ... +60 °C
● during transport-40 ... +80 °C
● of the enclosureIP20
● valve monitoringYes
design of the product20 F-DI, 4 F-DQ, 2 DQ
readback time maximum400 ms
total current maximum7 A
● at DC rated value24 V
conducted interference
— unshielded maximum600 m
● monitored start-upYes
● non-safety-related0
Product Lifecycle (PLM)PM300:Active Product
● at AWG cables solid1x (20 ... 16), 2x (20 ... 16)
General Product ApprovalFunctional Safety/Safety of Machinery
Release-delay (EF001129)-
● PROFIBUS DP protocolYes; when using the DP interface module; 64 bit cyclical data
● PROFINET IO protocolYes; when using the PN interface module; 64-bit cyclic data
● for signal <1> at DC15 ... 30
● with signal <0> at DC-3 ... +5 V
Export Control RegulationsAL : N / ECCN : EAR99
● according to IEC 615083
● according to IEC 620613
● at AWG cables stranded1x (20 ... 16), 2x (20 ... 16)
● for signal <1> typical2.6 mA
● parameterizable inputsYes
Standard lead time ex-works80 Day/Days
Surcharge for Raw MaterialsNone
With start input (EF003342)-
operating frequency maximum2 000 1/h
operating power rated value4.5 W
● EMERGENCY STOP functionYes
● parameterizable outputsYes
● safety-related circuitsYes
Evaluation inputs (EF008245)-
Package size unit of measureMM
Safety Integrity Level (SIL)
● safety-related 2-channel4
Substance Prohibitance (Date)05/28/2009
type of electrical connectionspring-loaded terminal (push-in)
● muting, 2 sensor-parallelYes
● muting, 4 sensor-parallelYes
input current at digital input
input voltage at digital input
insulation voltage rated value50 V
protocol optional is supported
● monitoring parameterizableYes
● position switch monitoringYes
● protective door monitoringYes
With muting function (EF004057)false
configuration software requiredYes; Safety ES V1.0 and higher
duration of inrush current peak
wire length of the signal cable
● evaluation: enabling switchYes
● evaluation: selector switchYes
● muting, 4 sensor-sequentialYes
● proximity switch monitoringYes
With feedback circuit (EF003343)-
Rail mounting possible (EF003972)FALSE
With approval for TÜV (EF004144)true
With detachable clamps (EF003340)true
dark period of the common drivers3 ms
number of function blocks typical50
recovery time of the safe outputs0 ms
Type Test Certificates/Test ReportConfirmation
air pressure according to SN 3120590 ... 106 kPa
control supply voltage rated value24 V
relative humidity during operation10 ... 95 %
● monitoring of floating sensorsYes
With approval for BG BIA (EF004145)-
product function removable terminalYes
category according to EN ISO 13849-14
surge voltage resistance rated value800 V
● EMERGENCY-OFF circuit monitoringYes
Article Number (Market Facing Number)3SK2122-2AA10
SIL according to IEC 61508 (EF009889)3
Voltage type for actuating (EF008242)DC
stop category according to EN 60204-10 / 1
● for testing contact-based sensors4
● pressure-sensitive mat monitoringYes
Type of electric connection (EF003961)Spring clamp connection
WEEE (2012/19/EU) Take-Back ObligationYes
● monitoring of non-floating sensorsYes
reference code according to IEC 81346-2F
● evaluation: two-hand operator panelYes
With approval according to UL (EF001783)true
● two-hand control according to EN 574Yes
Category according to EN 954-1 (EF006782)-
input delay time at digital input maximum150 ms
touch protection against electrical shockfinger-safe
product function suitable for AS-i Power24VNo
protocol is supported AS-Interface protocolNo
● due to burst according to IEC 61000-4-42 kV (power ports) / 1 kV (signal ports)
● magnetically operated switch monitoringYes
● protective door monitoring with tumblerYes
Suitable for monitoring of valves (EF007272)true
product function diagnostics with CTT2 slaveNo
type of connectable conductor cross-sections
● finely stranded with core end processing1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²)
● at digital output with signal <0> maximum0.1 mA
Stop category according to IEC 60204 (EF007498)0 + 1
hardware fault tolerance according to IEC 615081
performance level (PL) according to ISO 13849-1e
type of digital inputs according to IEC 60947-1Type 1
vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0.75 mm
PFHD with high demand rate according to EN 620610.000000012 1/h
Rated control supply voltage Us at DC (EF003980)['24', '24']
ingress aquisition time at digital input maximum60 ms
● opto-electronic protection device monitoringYes
EMC emitted interference according to IEC 60947-1class A
SIL Claim Limit (subsystem) according to EN 620613
PFDavg with low demand rate according to IEC 615080.000018
Type of safety according to IEC 61496-1 (EF004105)-
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
field-based interference according to IEC 61000-4-310 V/m
● at the digital outputs short-circuit protectionYes
Region Specific PriceGroup / Headquarter Price Group41L / 41L
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '-']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '-']
Suitable for monitoring of tactile sensors (EF007271)-
● evaluation: electro-sensitive protective equipmentYes
AWG number as coded connectable conductor cross section
Suitable for monitoring of magnetic switches (EF007266)true
Suitable for monitoring of position switches (EF007270)true
installation altitude at height above sea level maximum2 000 m
protocol is supported ASIsafe (Safety at work) protocolNo
Performance level according to EN ISO 13849-1 (EF007399)-
Suitable for monitoring of proximity switches (EF007267)true
design of the contactless switching element safety-relatedP potential
diagnostics test interval by internal test function maximum1 000 s
Suitable for monitoring of emergency-stop circuits (EF007268)true
number of outputs as contact-less semiconductor switching element
Number of outputs, safety related, delayed, with contact (EF003345)-
switching capacity current of semiconductor outputs at DC-13 at 24 V4 A
Number of outputs, safety related, delayed, semiconductors (EF003347)-
Number of outputs, safety related, undelayed, with contact (EF003344)0
Compliance with the substance restrictions according to RoHS directiveSince: 28.05.2009
number of outputs as contact-affected switching element safety-related
Number of outputs, safety related, undelayed, semiconductors (EF003346)4
Number of outputs, signalling function, delayed, with contact (EF003349)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Suitable for monitoring of optoelectronic protection equipment (EF007269)true
Number of outputs, signalling function, delayed, semiconductors (EF003351)-
Number of outputs, signalling function, undelayed, with contact (EF003348)-
Number of outputs, signalling function, undelayed, semiconductors (EF003350)-
connectable conductor cross-section finely stranded with core end processing0.5 ... 1 mm²
suitability for use for monitoring of optoelectronic protective devices according to IEC 61496-1Yes
General Product ApprovalFunctional Safety/Safety of MachineryDeclaration of ConformityConfirmationType Examination CertificateTest CertificatesotherType Test Certificates/Test ReportConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top