Key Specifications
:
EAN:4011209913554
UPC:887621548872
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209913554
UPC887621548872
ETIM5
IDEA4
depth91.6 mm
width22.5 mm
UNSPSC15
eClass6
height100 mm
● at DC
● solid1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
Group CodeR711
wire length
● maximum6 500 ms
● typical6 500 ms
Date5/5/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorNone
● stranded1x (20 ... 16), 2x (20 ... 16)
Product Group3761
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85364900
Product familySIRIUS 3SK1 Standard basic units
last modified:3/29/2022
pulse duration
Net Weight (kg)0,167 Kg
design of input
— rated value24 V
● start inputYes
Depth (EF000049)91.6
Model (EF000010)-
Width (EF000008)22.5
fastening methodscrew and snap-on mounting
product categorySafety relays
shock resistance10g / 11 ms
Country of originGermany
Height (EF000040)100.0
Marine / Shippingother
mounting positionany
● as NO contact
● at DC maximum85 ms
● safety switchYes
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-40 ... +80 °C
● feedback inputYes
● safety-related
Packaging Dimension36,00 x 109,00 x 152,00
Product DescriptionSIRIUS safety relay Basic unit Standard series electronic enabling circuits 2 enabling circuits plus 1 signaling circuit Us = 24 V DC Spring-type terminal (push-in)
ambient temperature
degree of pollution3
product designationsafety relays
suitability for use
● finely stranded
overvoltage category3
● during operation-25 ... +60 °C
design of the productSolid-state enabling circuits
control supply voltage
performance level (PL)
power loss [W] maximum2 W
Product Lifecycle (PLM)PM300:Active Product
design of the cascadingyes
EMC emitted interferenceIEC 60947-5-1, Class A
General Product ApprovalEMC
Release-delay (EF001129)-
— instantaneous contact2
Export Control RegulationsAL : N / ECCN : EAR99
switching capacity current
● according to IEC 615083
● according to IEC 620613
Safe failure fraction (SFF)99 %
Standard lead time ex-works180 Day/Days
Surcharge for Raw MaterialsNone
With start input (EF003342)true
operating frequency maximum2 000 1/h
● safety-related circuitsYes
Evaluation inputs (EF008245)One- and two-channel
Package size unit of measureMM
Safety Integrity Level (SIL)
Type Examination Certificate
— with core end processing1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²)
● according to ISO 13849-1e
type of electrical connectionspring-loaded terminal (push-in)
insulation voltage rated value50 V
make time with automatic start
make time with monitored start
With muting function (EF004057)false
— without core end processing1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
● of the sensor input minimum60 ms
With feedback circuit (EF003343)true
product function parameterizablesensor floating / sensor non-floating, monitored start-up / automatic start, 1-channel / 2-channel sensor connection, cross-circuit detection, startup testing
Rail mounting possible (EF003972)FALSE
With approval for TÜV (EF004144)true
With detachable clamps (EF003340)false
air pressure according to SN 31205900 ... 1 060 hPa
relative humidity during operation10 ... 95 %
● monitoring of floating sensorsYes
With approval for BG BIA (EF004145)-
product feature cross-circuit-proofYes
category according to EN ISO 13849-14
protection class IP of the enclosureIP20
surge voltage resistance rated value800 V
— safety-related delayed switching0
Article Number (Market Facing Number)3SK1112-2BB40
Functional Safety/Safety of MachineryDeclaration of Conformity
SIL according to IEC 61508 (EF009889)3
Voltage type for actuating (EF008242)DC
stop category according to EN 60204-10
Type of electric connection (EF003961)Spring clamp connection
WEEE (2012/19/EU) Take-Back ObligationYes
installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
● monitoring of non-floating sensorsYes
● of the ON pushbutton input minimum0.15 s
reference code according to IEC 81346-2F
With approval according to UL (EF001783)true
— safety-related instantaneous contact0
● cascading input/functional switchingYes
Category according to EN 954-1 (EF006782)-
recovery time after power failure typical6.5 s
suitability for interaction press controlNo
touch protection against electrical shockfinger-safe
safety device type according to IEC 61508-2Type B
● magnetically operated switch monitoringYes
Suitable for monitoring of valves (EF007272)-
type of connectable conductor cross-sections
type of electrical connection plug-in socketNo
type of voltage of the control supply voltageDC
● of semiconductor outputs at DC-13 at 24 V2 A
number of sensor inputs 1-channel or 2-channel1
Stop category according to IEC 60204 (EF007498)0
hardware fault tolerance according to IEC 615081
required spacing for grounded parts at the side5 mm
type of the safety-related wiring of the inputssingle-channel and two-channel
vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0.75 mm
PFHD with high demand rate according to EN 620610.000000001 1/h
Rated control supply voltage Us at DC (EF003980)['-', '24']
suitability for operation device connector 3ZY12No
● for signaling function instantaneous contact1
PFDavg with low demand rate according to IEC 615080.000007
Type of safety according to IEC 61496-1 (EF004105)-
make time with automatic start after power failure
Region Specific PriceGroup / Headquarter Price Group41L / 41L
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
Suitable for monitoring of tactile sensors (EF007271)-
Suitable for monitoring of magnetic switches (EF007266)true
Suitable for monitoring of position switches (EF007270)true
installation altitude at height above sea level maximum2 000 m
number of outputs as contact-affected switching element
Performance level according to EN ISO 13849-1 (EF007399)Level e
Suitable for monitoring of proximity switches (EF007267)-
recovery time after opening of the safety circuits typical30 ms
type of connectable conductor cross-sections at AWG cables
Suitable for monitoring of emergency-stop circuits (EF007268)true
● with Cu 1.5 mm² and 150 nF/km per sensor circuit maximum4 000 m
backslide delay time after opening of the safety circuits typical40 ms
number of outputs as contact-less semiconductor switching element
Number of outputs, safety related, delayed, with contact (EF003345)-
Number of outputs, safety related, delayed, semiconductors (EF003347)0
Number of outputs, safety related, undelayed, with contact (EF003344)-
Compliance with the substance restrictions according to RoHS directiveSince: 05.11.2012
Number of outputs, safety related, undelayed, semiconductors (EF003346)2
T1 value for proof test interval or service life according to IEC 6150820 y
Number of outputs, signalling function, delayed, with contact (EF003349)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value of magnet coil
Suitable for monitoring of optoelectronic protection equipment (EF007269)true
Number of outputs, signalling function, delayed, semiconductors (EF003351)-
Number of outputs, signalling function, undelayed, with contact (EF003348)-
Number of outputs, signalling function, undelayed, semiconductors (EF003350)1
design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requirednot required
General Product ApprovalEMCConfirmationFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingType Examination CertificateType Test Certificates/Test ReportMarine / ShippingotherRailwayConfirmationConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents